TDE Digalox DPM72-MP Graphical DIN Meter Owner’s Manual

May 15, 2024
TDE

Digalox® DPM72-MPP/MPPA/MPPV-DIN
Instruction manual (Rev-2023-03)
**Analogue signal measuring instrument for DIN rail
**

Package contents: Digalox® DPM72, 5 jumpers, 2 instruction manuals (EN + DE)

Safety instructions

  • Read instruction manual carefully before operating the device! Keep for later reference.
  • Mounting and installation must be carried out by suitably qualified and competent persons only.
  • When working on the device hazardous voltages must not be connected to the device! The terminals J1-J12 are not isolated from the measuring circuit.
  • The device must not be used as the only protective device or protective shutdown.
  • The device is not intended to protect persons or facilities against harm. Specific devices must be used to guarantee safety (protection relays, cut-off switches, etc.).
  • When connecting switches to the terminals J1-J8, only switches must be used whose isolation voltage is at least twice the maximum occurring measurement voltage. For example, when measuring 30 V DC switches must be isolated for at least 60 V.
  • Do not open the housing!
  • Do not use the device in the presence of explosive or flammable substances!
  • All cables carrying hazardous voltages must be secured with external separators.

Meaning of symbols

General warning sign
(Attention, observe the documentation!)
Warning of an electrical hazard

Intended use

  • Measurement of current, voltage, power and frequency in the specified measuring ranges.
  • Indoor use non condensing, non corrosive.
  • Mounting on DIN rail or screwing on.
  • Failure to comply with these instructions will void all guarantee and warranty.

Description

Depending on type the measurement modes analogue signal (2×) 0/2 to 10 V and/or (2×) 0/4 to 20 mA AC/DC are supported. As individually adjustable threshold values are reached, two galvanically isolated alarm outputs enable the device to perform switch-on or switch-off operations.
Using the configuration software “Digalox® Manager” the device can be configured, e.g. thresholds for alarm output, hysteresis, and more.
Depending on the model, measured values can be transmitted via XBEE radio technology or RS485 Modbus interface. In addition, the device features a counting function with data retention. This enables operating-hours-counters or time-counters for exceeding and falling below threshold values, as well as single pulse counting (MPP) or double pulse counting (MPPV). The device can be mounted on DIN rails as well as on other backgrounds through corresponding holes in the housing.
In the “Downloads” area of www.digalox.com you can find the latest version of the instruction manual and the software “Digalox® Manager”.

Product overview

  1. 2 optocoupler switch outputs
  2. Jumper pins J1–J12
  3. Supply voltage input
  4. Interface (XBEE / RS485)
  5. Measurement inputs

Mounting

Hook the device into the top-hat rail from above and then press it at the bottom until the latch engages. Alternatively, attach the device with 4 screws.

Electrical connections

WARNING: The device may only be operated in one of the connection options shown! Use an ultra-fast-acting fuse (FF) at the current measurement input.

Supply (Digalox)| Legend
Voltage source, e.g. active sensor or sensor with voltage supply
Current source, e.g. active sensor or sensor with voltage supply
---|---

DPM72-MPP

| 10 V analogue signal
---|---
20 mA analogue signal| 20 mA and 10 V analogue signal

DPM72-MPPA

20 mA analogue signal 2 × 20 mA analogue signal

DPM72-MPPV

10 V analogue signal 2 × 10 V analogue signal

Configuration

Connect the device to a computer:
XBEE: Insert the XBEE stick into the computer. The device driver is installed automatically if the computer is connected to the Internet. In order to reset the XBEE settings, short-circuit terminal J8.
RS485: Short-circuit terminal J8. Disconnect the device from the Modbus network and connect it to the computer using an RS485 USB adapter. After completing the configuration, open J8 again.
Start the “Digalox® Manager” software and connect it to the device. Settings can then be made on the various tabs and saved in the device.
After restart, the first four display values are provided or the one selected via connections J4-J6 and the three following display values.

Maintenance

Periodically check all external cable connections.

Cleaning

Observe the safety instructions before cleaning the device. Clean the device with a dry lint-free soft cloth. Do not use solvents.

Specification

| DPM72-MPPA| DPM72-MPP| DPM72-MPPV
---|---|---|---
Supply| 12 – 24 V AC/DC ±10% (50/60 Hz ±10%), galvanically isolated
Power consumption| Max. 1.2 W
Measuring range voltage| | ±30 V DC, 20 V AC, 10 – 500 Hz
Accuracy voltage| –| ±0.5 % true RMS
Internal resistance voltage| –| 102 kΩ
Measuring range ampere| 20 mA AC/DC (max. 100 mA), 10 – 500 Hz| –
Accuracy ampere| ±0.5 % true RMS| –
Internal resistance ampere| 6.2 Ω| –
Measuring range frequency| 10 – 1000 Hz
Accuracy frequency| ±0.1 Hz
Measuring value update| 5 Hz (32 kHz sampling rate)
Alarm outputs| 2 optocoupler outputs max. 30 V DC, 50 mA
Connections (measuring inputs)
–  Wire gauge
–  Wire strip length
–  Pitch| 0.2 – 3.3 mm² (24 to 12 AWG)
7 – 8 mm
7.62 mm
Connections (supply, alarm outputs and RS485)
–  Wire gauge
–  Wire strip length
–  Pitch| 0.13 – 1.3 mm² (26 to 16 AWG)
6 – 7 mm
3.5 mm
Operating temperature| 0 °C to +50 °C
Storage temperature| -20 °C to +70 °C
Operating altitude| 0 to 2000 m above sea level
IP code| IP00
Dimensions| 67.5 mm × 93.5 mm × 61.2 mm
Depth| 61.2 mm (with plugs, cable outlet at the front)
78.7 mm (with antenna)
Net weight| 106 g

Dimensions [mm]

Contact information

TDE Instruments GmbH, Gewerbestraße 8, D-71144 Steinenbronn
Phone: +49 7157 20801
E-mail: info@tde-instruments.de
Internet: www.tde-instruments.de, www.digalox.com