SALUS Fan Coil thermostat FC600 User Guide
- June 6, 2024
- SALUS
Table of Contents
- Introduction
- Product Compliance
- Safety Information
- Terminals description
- Wiring Option
- Button Functions
- LCD Icon description
- Installation in Online mode (with UGE600 and internet connection)
- Installation in Offline mode
- Setting Time
- Change the Setpoint temperature
- Installer Settings in Offline Mode
- Changing from Offline Mode to Online Mode
- Factory Reset
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
SALUS Fan Coil thermostat FC600 User Guide
Introduction
A SALUS FC600 is a device suitable for controlling your fan coil unit in both 2 pipe and 4 pipe systems and for managing the temperature in your home and/or working environment. For an internet connection (Online Mode), this product must be used with the SALUS Universal Gateway (UGE600) and the SALUS Smart Home App . You can also use the SALUS FC600 without an internet connection (Offline Mode). Go to www.salus-manuals.com for the full PDF version of the manual.
Product Compliance
This product complies with the essential requirements and other relevant provisions of Directives 2014/30/EU, 2014/35/EU, 2014/53/EU and 2011/65/EU. The full text of the EU Declaration of Conformity is available at the following internet address: www.saluslegal.com
Safety Information
Use in accordance with the regulations. Indoor use only. Keep your equipment completely dry. Disconnect your equipment before cleaning it with a dry towel.
Terminals description
Terminal Name | Function |
---|---|
L,N | 230V AC power supply |
V1 | 4 pipe: Heating valve output – 230V AC |
2 pipe: Heating or Cooling valve output – 230V AC
V2| 4 pipe: Cooling valve output – 230V AC
2 pipe: N/A
F1| Fan Speed control (Low level) – 230V AC
F2| Fan Speed control (Medium level) – 230V AC
F3| Fan Speed control (High level) – 230V AC
S1| Heat/Cool changeover
(or pipe sensor – only in 2-pipe system)*
S2| Occupancy sensor or external sensor
COM| Common Terminal for sensor and switch
Wiring Option
Button Functions
Key | Function |
---|---|
Increase | |
Decrease | |
Fan Speed: Low, Medium, High, Auto, Off | |
Mode button | |
Digital | Heat/Cool/Eco selection |
Programmable | Permanent override, AUTO, Heat/Cool/Eco selection |
schedule, Sensor offset, Time & Dat
*Mode button operation can be different in Online and Offline mode and also depends of the S1/COM/S2 inputs usage
| Short press: Confirm function Long press (2 sec): Activate/deactivate
Standby Mode.
LCD Icon description
- Auto heat/cool selection
- Schedule icon
- Permanent/temporary override
- Fan is running (icon is animated)
- Fan speed (low, medium, high, Auto, OFF)
- Wireless communication with the Universal Gateway
- FC600 is connected to the Universal Gateway and Internet
- Temperature unit
- Heating Mode ON
- Cooling Mode ON
- Standby mode
- Occupancy/vacancy sensor
- Lock function
- AM/PM
- Eco Mode
- Day indicator
- Filter icon
- Current time
- Sensor indicators
- Timer icon
- Program number
- S1/COM Sensor indicators
- S2/COM Sensor indicators
- Room/setpoint temperature
- Settings icon
Schedule Mode
Temporary Override
Permanent Override
Installation in Online mode (with UGE600 and internet connection)
Make sure that your Universal Gateway is installed and added to the app. The
LED must be blue.
Set up your device on the App
Success! Installation completed. (Standby Mode)
If you want to turn the FC600 on press or switch it via the App
Installation in Offline mode
Press UP/DOWN to select 2 or 4 pipe
Note: If you are using S1, S2 terminals please select the relevant settings from the table below
51 noFn | Manual (no function) |
---|---|
51 MO | Heat/Cool changeover (external switch) |
51 Auto | Auto Heat/Cool changeover |
51 sens | Manual with connected pipe sensor (2-pipe system only) |
S2 noFn | Manual (no function) |
52 door | Occupancy sensor |
52 sens | External temperature sensor |
Press UP/DOWN to select the operating mode. It can be (Cooling), (Heating or
(Cooling and Heating). Press to confirm your choice
Success! Installation completed. Press for 2 sec to launch the thermostat.
Setting Time
Press for 2 seconds and press to confirm
Press UP/DOWN to select the hour format. Press to confirm your option.
Press UP/DOWN to set the hour. Press to confirm your option. Follow the same
steps to set the minutes.
Change the Setpoint temperature
Press UP/DOWN to set the temperature
Press to confirm the changes
Installer Settings in Offline Mode
(in Online Mode installer settings are available via the SALUS Smart Home App)
Note: To view the full list of parameters, please consult the full manual at
www.salus-manuals.com
Changing from Offline Mode to Online Mode
If you want to use the internet App and the Universal Gateway, you need to change your thermostat settings from Offline Mode to Online Mode. For that please follow the steps below:
Press from the App and follow
You are now in Standby Mode
All system settings will be automatically saved into SALUS cloud server. You don’t need to do installation again in Online mode.
Factory Reset
If you have made an error, need to change your thermostat parameters or want to return to the factory settings, please follow steps below.
Note: This action will permanently remove all your settings
Distributor of SALUS Controls:
QL CONTROLS Sp. z o.o., Sp. k.
ul. Rolna 4
43-262 Kobielice
Poland
salus@salus-controls.pl
Importer:
SALUS Controls Plc Units 8-10 Northfield Business Park
Forge Way, Parkgate, Rotherham
S60 1SD, United Kingdom
Distribuidor Oficial para España y Portugal: Sysclima
Polígono de la Serna
Calle C, Nave 6.14
E-31500 Tudela (Navarra)
www.sysclima.com
SALUS Controls is a member of the Computime Group
Maintaining a policy of continuous product development SALUS Controls plc
reserve the right to change specification, design and materials of products
listed in this brochure without prior notice.
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>