SALUS iT500 Internet Thermostat Installation Guide
- June 6, 2024
- SALUS
Table of Contents
- FEATURES:
- Technical specification
- Connecting the gateway to your existing router
- Inserting the batteries in the iT500 Thermostat
- iT500 Plus application
- LCD icon description
- Button functions
- Installation of wall bracket docking (optional)
- Desk mount option iT500
- iT500RX receiver switch functions
- iT500RX terminals description
- Wiring diagrams for single heating zone
- + Wiring diagram for 2 heating zones
- Installation of iT500RX receiver
- Setting up the iT500 thermostat
- Pairing iT500 with iT500RX receiver
- Pairing the iT300 to the thermostat
- Selecting your system configuration
- Setting the time and date
- Operating modes
- Setting the temperature
- Lock Function
- Program schedule for heating zone
- Program schedule for hot water system
- References
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
iT500 Internet Thermostat
Installation Manual
DISTRIBUTOR OF SALUS CONTROLS:
QL CONTROLS Sp. z o.o., Sp. k.
Rolna 4,
43-262 Kobielice,
Poland| Importer:
SALUS Controls Plc
Units 8-10 Northfield Business Park
Forge Way, Parkgate, Rotherham
S60 1SD, United Kingdom
---|---
www.salus-controls.eu
SALUS Controls is a member of the Computime Group
Maintaining a policy of continuous product development SALUS Controls plc
reserves the right to change specification, design, and materials of products
listed in this brochure without prior notice.
Introduction
The iT500 controls your heating and hot water from anywhere via your smartphone or laptop. Your pc and laptop connect to the system using an existing broadband connection. The system is wireless so it’s easy to install.
FEATURES:
-
Access and control your heating and hot water via the internet
-
Compatible with your PC or smartphone – they connect to the system using your existing broadband connection
-
Touch sensor panel
-
The internal system uses 868 MHz for robust communication
-
3 system configurations:
– One central heating zone only
– Two central heating zones (optional iT300 remote sensor required for second zone)
– One central heating zone plus hot water -
ECO & HOLIDAY mode
-
Free iT500 Plus app to download
Box contains:
– iT500TR thermostat
– iT500RX receiver (a wireless receiver that will connect to your boiler.
It is suitable for combination and system boiler).
– iTG500 Internet gateway – connects via a short cable to your broadband
internet router.
The gateway enables internet access and control of your system.
Product compliance
This product complies with the following EU Directives: Electromagnetic
Compatibility 2014/30/EU, Low Voltage Directive 2014/35/EU, Directive
2014/53/EU and 2011/65/EU. Full information is available on the website
www.saluslegal.com
Safety information
Use in accordance with national and EU regulations. Use the device only as
intended, keeping it in a dry condition. The product is for indoor use only.
Installation must be carried out by a qualified person in accordance with
national and EU regulations.
Technical specification
Supply: iT500 – 2 x AA Batteries
iT300 – 2 x AAA Batteries
iT500RX – 230 V AC 50Hz
Rating Max: CH1: 16 A resistive, 5 A inductive
CH2: 5 A resistive, 3 A inductive
Temperature range: 5°C – 35°C (in step 0,5°C)
Frost protection temperature: 5°C – 9°C (in step 0,5°C)
Hysteresis: 1°C
Storage temperature: -20°C to 60°C
Protection degree IP: IP 30
Connecting the gateway to your existing router
Inserting the batteries in the iT500 Thermostat
- Remove the battery cover from the base of the iT500 Thermostat.
- Make a note of the serial number printed inside the base of the iT500 Thermostat.
- With the unit face down, insert the first battery supplied into the right-hand side of the base of the iT500 Thermostat.
You can make a note of your STA number here for future reference:
- Insert the second battery supplied into the left-hand side of the base of the iT500 Thermostat.
- Ensure the batteries are fitted securely in the base of the iT500 Thermostat.
- Replace the battery cover with the base of the iT500 Thermostat.
iT500 Plus application
Download the iT500 Plus app, create an account and register your device.
Follow the on-screen instructions to complete all the steps.
Features available only on the App:
- HOLIDAY mode
- Antifrost temperature changing
- Energy-saving mode (set the lowest schedule temp.)
- Simplified schedule setup
You can add a few iT500 thermostats to one account.
LCD icon description
1. Settings indicator
2. Internet indicator
3. RF signal indicator
4. Low battery status
5. Holiday indicator
6. Button lock indicator
7. Temperature unit
8. Temperature indicator
9. Hot water heating in continuous mode
10. Hot water override
11. Automatic mode
12. Antifrost mode| 13. Hot water heating
14. Hot water indicator
15. Cooling mode indicator (zone 2)
16. Zone 2 indicator
17. Heat mode indicator (zone 2)
18. Cooling mode indicator (zone 1)
19. Zone 1 indicator
20. Heat mode indicator (zone 1)
21. Program number indicator
22. Clock display
23. Day of the week
---|---
Button functions
√ | – Confirm | ∧ | – Increase |
---|---|---|---|
– Return | – Display ON (display highlighting) | ||
– Settings / zone changing | ∨ | – Decrease |
Installation of wall bracket docking (optional)
For best results mount iT500 1.5m from ground level.
- Attach the wall mounting bracket to a suitable wall using the fittings supplied and the built-in level.
- After first ensuring that the bracket is secure, clip the iT500 into place by aligning the recess on the back of the unit to the bracket and clipping into place.
- Once clipped into place, ensure the unit is securely seated on the bracket.
Desk mount option iT500
For the desk-mounted option, simply clip the clear stand supplied separately into the back of the unit.
iT500RX receiver switch functions
- AUTO – receiver operate in automatic mode (works according to thermostat or app)
- MANUAL – receiver operates according to the switch located below
- OFF – the receiver is disabled
- CH – in manual mode, zone 1 are turned ON
- AUX-in manual mode, zone 2 are turned ON
- CH/AUX-in manual mode, zone 1 and zone 2 (or HW) are turned ON
iT500RX terminals description
| Terminal name| Function
---|---|---
CH (zone 1)| L, N| 230V AC power supply
NC| Normally closed terminal
NO| Normally open terminal
COM| Common Terminal
AUX (zone 2)| NC| Normally closed terminal
NO| Normally open terminal
COM| Common Terminal
Wiring diagrams for single heating zone
+ Wiring diagram for 2 heating zones
Installation of iT500RX receiver
Note: Always shut off the AC mains supply before installing or working on any components.
- Loosen the screws at the bottom of the receiver unit and unclip the front of the unit.
- Fit the back of the receiver unit to the wall using the fittings supplied. Then wire up the receiver using a proper diagram.
- Clip the front of the unit back and securely screw the front of the receiver in place.
Setting up the iT500 thermostat
After powering up iT500 for the first time the display will go through the following sequence.
Pairing iT500 with iT500RX receiver
FAILSAFE MODE: In the event of RF signal loss, your system will be switched on for 4 minutes, then off for 11 minutes. If you want to disable FAILSAFE MODE when RF link has been lost then move the slide switch on iT500RX to either the Manual or Off position.
Pairing the iT300 to the thermostat
Note: iT300 was purchased separately. Can only be used if your system supports a second central heating zone.
The iT300 should be installed in the area of the house that the second zone
will be controlled from, ie. Upstairs.
Please note the red LED on the iT300 will continue to flash and eventually
timeout.
Selecting your system configuration
**** This menu should only be entered by the installer as changes can have a
detrimental effect on your heating system.
At any time press for a return to the previous step or hold for 5 seconds to
return to the home screen.
The countries marked with * do not observe Daylight Saving Time. For details
please see below.
DST (Daylight Saving Time) ON will automatically change your time from summer
to winter.
Setting the time and date
When connected to the internet, the iT500 will set time and date automatically. However, this can also be set manually.
Operating modes
Setting the temperature
Note: If you set the temperature in AUTO mode (temporary override) the setpoint temperature won’t be changed until the next program starts.
Lock Function
To enable or disable the lock function press and hold and buttons together.
Program schedule for heating zone
You can easily set your schedule via iT500 Plus app . If you want to set
schedules directly by the iT500 thermostat, please follow the instruction
below.
In the iT500 thermostat, you can define 6 scheduled programs per day. You can
set different temperature levels for each program. While programming at
specific time intervals you must be aware that you are about to set at what
time the program will start. For example, if you set program 1 for 6:00 (AM)
it means the program is going to run at 6:00 (AM) and will run till the time
set for the next program. Example of 4 temperature levels for 6 schedule
programs:
Note: When you set a program schedule, necessarily set all 6 programs. I.e. if you want to set 2 temperature levels, you need to set the first temperature level for the 1 to 5 program and set the second temperature level only for program 6.
Program schedule for hot water system
Note: In the program schedule for the hot water system (HW) you can set 3 schedule programs per day. For each HW program, you must define the time of start and the time of the end.
References
- controls.dk is hosted by UnoEuro Webhosting
- Salus – Smart Technology for your comfort
- Choose your country – Salus
- SALUS Controls - intelligent temperature control
- iT500 Login / Register