SALUS VS30W Programmable Wired Thermostat with Digital Display Installation Guide

June 6, 2024
SALUS

SALUS VS30W Programmable Wired Thermostat with Digital Display

SALUS VS30W Programmable Wired Thermostat with Digital Display
featured

Relay module RM-16A opens and closes the circuit in order to affect the work of other devices. Some uses of the module RM-16A with other Salus products are shown below:

  1. Connection of the thermostat with the high voltage relay 230V (e.g. VS30/RT200/ERT20/ERT30/ERT50/VS10) with a gas boiler which requires free-voltage output NO/COM or NC/COM
  2. Connection of the SALUS temperature regulator with the NO/COM relay (e.g. 091FL) with the boiler con-trol which requires NC/COM output (NC/COM output is normally required in the solid fuel boiler controls )
  3. Connection of the receiver transmitting power higher than it is allowed by the relay in a regulator. The maximum electricity consumption of the receiver cannot exeed 16A
  4. Connection of the devices other than electro thermal actuators with the wiring centre ( KL06-M/KL08NSB /KL08RF/KL10/KL10RF) e.g. if you want to connect a pump or an electric heating mat instead of a electro thermal actuator.

Introduction

The VS30 thermostat controls temperatures of individual heating zone in underfloor heating systems. Thermostat allows for significant savings thanks to the possibility of maximum reduction the set temperature. The full version of the manual in PDF format is available on the website www.salus- controls.eu

Product Compliance
This product complies with the following EU Directives: Electromagnetic Compatibility 2014/30/EU, Low Voltage Directive 2014/35/EU and RoHS 2011/65/EU. Full information is available on the website www.saluslegal.com

Safety Information
Use in accordance with national and EU regulations. Use the device only as intended, keeping it in a dry condition. The product is for indoor use only. Installation must be carried out by a qualified person in accordance with national and EU regulations.

Terminals description

Terminal Description
L,N Power Supply 230 V AC
NSB Night SetBack (output 230 V AC)
SL Switched output (230 V AC)
S1, S2 External temperature sensor

Proper thermostat placement

SALUS VS30W Programmable Wired Thermostat with Digital Display
fig1

Button Functions

SALUS VS30W Programmable Wired Thermostat with Digital Display
fig2

LCD Icon description

SALUS VS30W Programmable Wired Thermostat with Digital Display
fig3

1. Current active mode
2. Comfort mode
3. Standard mode
4. Economic mode
5. Automatic mode
6. PARTY mode
7. Holiday mode
8. Frost protection mode
9. Temperature unit
10. Manual mode / temp. override
11. Current / set temperature
12. Program number
13. AM/PM
14. Key lock
15. Day of the week
16. Settings
17. Time
18. Additional temp. sensor
19. Cooling
20. Heating

Installation

The VS30 thermostat has been designed for flush mounting in a standard electrical box with a diameter of 60 mm.
SALUS VS30W Programmable Wired Thermostat with Digital Display
fig4
Note: Use the rear plate of the VS30 thermostat only with this model.

Wiring diagrams
An additional temperatur Te sensor is optional.
VS30 thermostat in connection with actuator or pump
SALUS VS30W Programmable Wired Thermostat with Digital Display
fig5VS30 thermostat in connection with wiring centre
In this diagram, the VS30 thermostat manages the NSB function, more details about NSB function can be found on the next page.SALUS VS30W Programmable
Wired Thermostat with Digital Display fig6

Note: In the KL06 wiring centre, the SL terminal is marked with an arrow icon .

VS30 thermostat in connection with a boiler with a “NO” voltage free terminal through the RM-16A relay
NSB function is not active.
SALUS VS30W Programmable Wired Thermostat with Digital Display
fig7

Time and date setting

Note: During the first start-up, thermostat will automatically start time and date setting – in this case go to step 4.

Press any button to highlight the screen, then follow the steps below:
SALUS VS30W Programmable Wired Thermostat with Digital Display
fig8 Similarly to steps 5 and 6, set the minutes, year, month and day.

Temperature setting

Press any button to highlight the screen, then follow the steps below:
SALUS VS30W Programmable Wired Thermostat with Digital Display
fig10

Manual mode – temperature settings
There are 4 temperature levels available. In manual mode only one temperature level is active (icon in the frame indicates which mode is currently chosen). For each temperature levels you can set a different temperature.
SALUS VS30W Programmable Wired Thermostat with Digital Display
fig11 SALUS VS30W
Programmable Wired Thermostat with Digital Display fig12

Programming

Press any button to highlight the screen, then follow the steps below:

SALUS VS30W Programmable Wired Thermostat with Digital Display
fig13

Repeat steps 5 – 10 to set time and temperatures for next time ranges. No hour (–:–) on the display means whole day
is planned already. Schedule can be divided into maximum 6 time ranges.

NSB function – automatic mode

The NSB (Night SetBack) function can automatically change temperatures on VS35 daily thermostats via VS30 programmable thermostat connected to a wiring centre (or another external clock). NSB function switches between comfortable temperature and economic temperature .
SALUS VS30W Programmable Wired Thermostat with Digital Display
fig16 Note: For the NSB function to work, it is necessary to connect the wirings properly. Connection diagrams can be found on the previous page.

Press any button to highlight the screen, then follow the steps below:SALUS
VS30W Programmable Wired Thermostat with Digital Display
fig17

Installer settings

Press any button to highlight the screen, then follow the steps below:
SALUS VS30W Programmable Wired Thermostat with Digital Display
fig18 Note: To restore the thermostat’s factory settings, in step 2 set the PSuu to 47 code, and confirm the selection with the button.

dxx Function Value Description Default value

d01

|

Control method temperature

| 0| PWM algorithm|

0

1| Span ±0.5°C
2| Span ±1.0°C

d02

|

Offset temperature

| from -3.0°C to +3.0°C| If the thermostat indicates wrong temperature, you can correct it by ± 3.0°C|

0°C

d03

| Using a floor tempera- ture sensor (S1, S2)| 0| No sensor|

0

1| Sensor is connected

d04

| External sensor used for air

or floor temperature measurement (Function is active , when d03=1 )

|

0

| Thermostat measures the temperature only on the external sensor|

0

1

| The sensor is used as a protection against overheating the floor

d05

| Cooling mode control method| 1| Span ±0.5°C|

2

2| Span ±1.0°C

d06

| Type of thermoelectric actuator| 0| NO – normally open|

1

1| NC – normally closed

d07

|

Valve protection

| 0| OFF|

1

1| ON

d08

| Frost protection temperature|

5-17°C

| Frost protection / Holiday mode temperature|

5°C

d09

|

Clock format

| 0| 12 hour|

1

1| 24 hour

d11

|

Daylight Saving Time

| 0| OFF|

1

1| ON

d12

| Heating temperature limit|

5-35°C

| The maximum heating temperature that can be set by the user|

35°C

d13

| Cooling temperature limit|

5-40°C

| The minimum cooling temperature that can be set by the user|

5°C

d14

| Maximum floor temperature

(this function is active in heating mode when d04 = 1 )

|

6-45°C

| In order to protect the floor from overheating, heating will be turned OFF, when the maximum temp. of the floor sensor will be reached|

27°C

d15

| Minimum floor temperature

(this function is active in heating mode when d04 = 1 )

|

6-45°C

| In order to protect the floor, heating will be turned ON, when the

minimum temp. of the floor sensor will be reached

|

10°C

d16

| Lower floor temperature limit for cooling

(this function is active when d04 = 1 )

|

6-45°C

| In order to protect the floor, cooling will

be turned OFF, when the minimum temp. will be reached

|

6°C

d17| Choice of the default program| 1-5| Selection 1 of the 5 default programs| 1

d18

| Operating mode HEATING / COOLING| 0| Heating system|

0

1| Cooling system

Error codes

Error code Description
Err02 The maximum / minimum floor temperature has been exceeded
Err03 Temperature sensor is faulty
Err04 Temperature sensor is shorted

SAFETY INFORMATION

Before connecting the relay module with a different device make sure that its parame-ters are consistent with the RM-16A module specification. Incorrect connection may cause undesirable action, excessive overheating and combustion hazard. To avert the hazard make sure that the relay module RM-16A is correctly connected. The connection of the device can be done only by a qualified installer who has up-to-date eligibility.

INTRODUCTION

Relay module RM-16A opens and closes the circuit in order to affect the work of other devices. Some uses of the module RM-16A with other Salus products are shown below:

  1. Connection of the thermostat with the voltage relay 230V (e.g. VS30/RT200/ERT20/ERT30/ERT50/VS10) with a gas-fired boiler which requires free-voltage output NO/COM or NC/COM
  2. Connection of the SALUS thermostat with the NO/COM relay (e.g. 091FL) with the boiler control which needs NC/COM output (NC/COM output is normally required in the solid fuel boiler controls)
  3. Connection of the receiver transmitting power higher than it is allowed by the relay in a regulator. The maximum electricity consumption of the receiver cannot exeed 16A
  4. Connection of the devices other than electro thermal actuators with the wiring centre ( KL06-M/KL08NSB /KL08RF/KL10/KL10RF) e.g. if you want to connect a pump or an electric heating mat instead of a electro thermal actuator.

PRODUCT SPECIFICATION

Power:| 16A / 250V AC, 4000VA
INPUT NO/COM:| Connection of a regulator with the free voltage relay NO/COM
OUTPUT NC/COM/NO:| Output receiver
INPUT SL:| Connection of the regulator with the voltage relay 230V
POWER SUPPLY N/L:| Power of 230V AC/50Hz
Measurements:| 47x47x21

VISUAL ASPECT

SALUS VS30W Programmable Wired Thermostat with Digital Display
fig19

CONNECTION DIAGRAMS

  1. Connection of the thermostat with a voltage relay 230V (e.g. VS30/RT200/ERT20/ERT30/ERT50/VS10) to a gas boiler which requires free-voltage output NO/COM.
    SALUS VS30W Programmable Wired Thermostat with Digital Display
fig20

  2. Connection of the SALUS temperature regulator with NO/COM relay (e.g. 091FL) with a boiler control which requires NC/COM output ( NC/COM output is normally required in solid fuel boilers controls).

  3. Connection of the receiver transmitting power higher than it is allowed by the relay in a regulator. The maximuml electricity consumption of the receiver cannot exeed 16A

  4. Connection of the devices other than electro thermal actuators with the wiring centre ( KL06-M / KL08NSB / KL08RF / KL10 / KL10RF) e.g. if you want to connect a pump or an electric heating mat instead of a electro thermal actuator.
    SALUS VS30W Programmable Wired Thermostat with Digital Display
fig23