SALUS VS30B Programmable Wired Thermostat with Digital Display Installation Guide

June 6, 2024
SALUS

SALUS VS30B Programmable Wired Thermostat with Digital Display

Installation Manual

SALUS VS30B

DISTRIBUTOR OF SALUS CONTROLS:
QL CONTROLS Sp. z o.o., Sp. k.
Rolna 4,
43-262 Kobielice,
Poland

Importer:
SALUS Controls Plc
Units 8-10 Northfield Business Park
Forge Way, Parkgate, Rotherham
S60 1SD, United Kingdom

Computime and Compliance Symbols

www.salus-controls.eu
SALUS Controls is a member of the Computime Group
Maintaining a policy of continuous product development SALUS Controls plc reserve the right to change specification, design and materials of products listed in this brochure without prior notice.

Introduction

The VS30 thermostat controls temperatures of individual heating zone in underfloor heating systems. Thermostat allows for significant savings thanks to the possibility of maximum reduction the set temperature. The full version of the manual in PDF format is available on the website www.salus- controls.eu

Product Compliance

This product complies with the following EU Directives: Electromagnetic Compatibility 2014/30/EU, Low Voltage Directive 2014/35/EU and RoHS 2011/65/EU. Full information is available on the website www.saluslegal.com

Safety Information

Use in accordance with national and EU regulations. Use the device only as intended, keeping it in a dry condition. The product is for indoor use only. Installation must be carried out by a qualified person in accordance with national and EU regulations.

Terminals description

Terminal Description
L,N Power Supply 230 V AC
NSB Night SetBack (output 230 V AC)
SL Switched output (230 V AC)
S1, S2 External temperature sensor

Proper thermostat placement

Proper thermostat placement

Button Functions

Button Functions

LCD Icon description

LCD Icon description

  1. Current active mode
  2. Comfort mode
  3. Standard mode
  4. Economic mode
  5. Automatic mode
  6. PARTY mode
  7. Holiday mode
  8. Frost protection mode
  9. Temperature unit
  10. Manual mode / temp. override
  11. Current / set temperature
  12. Program number
  13. AM/PM
  14. Key lock
  15. Day of the week
  16. Settings
  17. Time
  18. Additional temp. sensor
  19. Cooling
  20. Heating

Installation

The VS30 thermostat has been designed for flush mounting in a standard electrical box with a diameter of 60 mm.

Installation

Note: Use the rear plate of the VS30 thermostat only with this model.

Wiring diagrams

An additional temperature sensor is optional.

VS30 thermostat in connection with actuator or pump

VS30 thermostat in connection with actuator or pump

VS30 thermostat in connection with wiring centre

In this diagram, the VS30 thermostat manages the NSB function, more details about NSB function can be found on the next page.

VS30 thermostat in connection with wiring centre

Note: In the KL06 wiring centre, the SL terminal is marked with an arrow icon ↓.

VS30 thermostat in connection with a boiler with a “NO” voltage free terminal through the RM-16A relay

NSB function is not active.

VS30 thermostat in connection with a boiler

Time and date setting

Note: During the first start-up, thermostat will automatically start time and date setting – in this case go to step 4.

Press any button to highlight the screen, then follow the steps below:

Time and date setting

Temperature setting

Press any button to highlight the screen, then follow the steps below:

Temperature setting

Manual mode – temperature settings

There are 4 temperature levels available. In manual mode only one temperature level is active (icon in the frame indicates which mode is currently chosen). For each temperature levels you can set a different temperature.

Temperature levels

Thermostat also has 2 additional modes:

2 Additional modes

Press any button to highlight the screen, then follow the steps below:

Highlight the screen

Programming

Press any button to highlight the screen, then follow the steps below:

Programming FIGURE 1

Programming FIGURE 2

Repeat steps 5 – 10 to set time and temperatures for next time ranges. No hour (–:–) on the display means whole day is planned already.
Schedule can be divided into maximum 6 time ranges.

NSB function – automatic mode

The NSB (Night SetBack) function can automatically change temperatures on VS35 daily thermostats via VS30 programmable thermostat connected to a wiring centre (or another external clock). NSB function switches between comfortable temperature and economic temperature .

To activate the automatic mode, select the icon. On display together with the icon, the controller indicates active temperature mode: or .

Note: For the NSB function to work, it is necessary to connect the wirings properly. Connection diagrams can be found on the previous page.

Press any button to highlight the screen, then follow the steps below:

NSB function

Installer settings

Press any button to highlight the screen, then follow the steps below:

Installer settings

Note: To restore the thermostat’s factory settings , in step 2 set the PSuu to 47 code, and confirm the selection with the button.

dxx Function

dxx Function Continued

Error codes

Error codes

References