SALUS RT100 Electronic Room Thermostat Instruction Manual
- June 6, 2024
- SALUS
Table of Contents
SALUS RT100 Electronic Room Thermostat
PRODUCT COMPLIANCE
This product complies with the essential requirements of the following EC Directives:
- Electro-Magnetic Compatibility directive 2004/108/EC
- Low Voltage Directive 2006/95/EEC
- EC Marking directive 93/68/EEC
SAFETY INFORMATION
These instructions are applicable to the Salus Controls model stated on the
front cover of this manual only, and must not be used with any other make or
model.
These instructions are intended to apply in the United Kingdom only, and
should be followed along with any other statutory obligations.
This accessory must be fitted by a Competent person, and installation must
comply with the guidance provided in the current editions of BS7671 (IEE
Wiring Regulations) and Part ‘P’ of the Building Regulations. Failure to
comply with the requirements of these publications could lead to prosecution.
Always isolate the AC Mains supply before carrying out any work on the
RT100 thermostat.
Please leave these instructions with the end user where they should be kept in
a safe place for future reference.
INTRODUCTION
A thermostat is a device that is used to switch the heating system in your
home on and off as needed. It works by sensing the air temperature and
switching on the heating when the air temperature falls below the thermostat
setting, and switching it off once the set temperature has been reached.
The RT100 from Salus Controls is a stylish and accurate mechanical thermostat
with a large, easy to adjust setting dial. The thermostat has been
specifically designed to be used Volt Free.
Features
- Simple to use
- Large dial
- Stylish Casing
- Volt Free contacts
- Two wire installation
- Temperature range between 10 ºC and 30 ºC
OPERATION
The RT100 is adjusted very easily by turning the rotary dial on the front of
the thermostat to the required temperature setting.
To adjust the set temperature, turn the rotary dial to the left to set a lower
temperature, or to the right to set a higher temperature.
INSTALLATION
Please read the important safety information at the start of this manual
before you begin to install the thermostat.
**Location
The ideal position to locate the RT100 thermostat is about 1.5m above floor
level, in a location where the thermostat is accessible, reasonably lit and
free from extremes of temperature and draughts. Do not mount the thermostat on
an outside wall, above a radiator or in a location where it may be subjected
to direct sunlight.
The RT100 can be mounted onto a back box, pattress or directly to the wall.
**
Preparing for Installation
The electrical connections to the RT100 are made inside the case. To gain
access to the wiring terminals, first remove the setting dial by gently
pulling it forwards. After removing the dial, undo the case securing screw
with a small crosshead screwdriver; you will now be able to pull the case
forwards to remove it.
**Preparing for Electrical Connection
After passing the wiring through the cable entry point, the RT100 can be
secured into position by the use of two screws.
The terminals in the RT100 will accept conductor sizes between 0.5 mm2 – 1.5
mm2, and the cable ends should be stripped of no more than 8mm of insulation.
**
ELECTRICAL CONNECTIONS
Do not restore the mains supply to the system until all associated items are
fully installed.
NOTE: All electrical installation work should be carried out by a
suitably qualified Electrician or other competent person. If you are not sure
how to install this thermostat consult either with a qualified electrician,
heating engineer or your boiler / heating system supplier for advice on how to
continue.
REASSEMBLING THE THERMOSTAT
Reassembly of the RT100 is very straightforward; just a reversal of the steps
taken earlier. Refit the cover and secure with the securing screw, and refit
the setting dial: do not force the dial – it will only locate in one position.
Do not remove or refit the cover of the RT100 without the mains supply to the
system being isolated.
ENERGY TIP
One way to set and use your room thermostat is to find the lowest temperature
setting that you are comfortable with, and then leave it set at this
temperature. You can do this by setting the room thermostat to a low
temperature, (for example 17 °C) and then increasing the setting by one degree
each day until you are comfortable with the room temperature – you won’t have
to adjust the thermostat further, as adjustment above this setting will waste
energy – a 1 °C increase in temperature is equal to 3% of your heating costs.
MAINTENANCE
TThe RT100 thermostat requires no special maintenance. Periodically, the outer
casing can be wiped clean using a dry cloth (please DO NOT use solvents,
polishes, detergents or abrasive cleaners, as these can damage the
thermostat).
There are no user serviceable parts within the unit; any servicing or repairs
should only be carried out by Salus Controls or their appointed agents.
Should the RT100 thermostat fail to function correctly, check:
- The RT100 temperature has been set correctly.
- Heating system time switch or programmer is switched on.
WARRANTY
Salus Controls warrants that this product will be free from any defect in materials or workmanship, and shall perform in accordance with its specification, for a period of two years from the date of purchase. Salus Controls sole liability for breach of this warranty will be (at its option) to repair or replace the defective product.
PRODUCT SPECIFICATION
Model: RT100
Type: Surface mounted mechanical room thermostat designed for volt free heating applications. heating applications.
Switching
Switching Voltage: 230V AC / 50Hz
Switching Current: 1A inductive
Contact Type: Volt Free
Temperature
Range: 5 ºC to 35 ºC
Differential: 0.5ºC to 0.8º
Environment
Operating Temperature: 0 ºC to + 50 ºC Storage Temperature: – 20 ºC to + 55 ºC
RT100 Warranty
Salus Controls warrants that this product will be free from any defect in materials or workmanship, and shall perform in accordance with its specification, for a period of two years from the date of purchase. Salus Controls sole liability for breach of this warranty will be (at its option) to repair or replace the defective product.
Sales: Email: sales@salus-tech.com Tel:
01226 323961
Technical: Email: tech@salus-tech.com Tel: 01226
323961
SALUS Controls Plc
Units 8-10 Northfield Business Park Forge Way, Parkgate, Rotherham S60 1SD,
United Kingdom
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>