SALUS VS10WRF Digital Programmable Wireless 4-In-1 Thermostat User Guide
- June 6, 2024
- SALUS
Table of Contents
SALUS VS10WRF Digital Programmable Wireless 4-In-1 Thermostat
Introduction
VS10..RF / VS20..RF is a room temperature thermostat that is used for wireless control of iT600 series devices such as: KL08RF wiring centre, TRV radiator valve and RX10RF boiler receiver. In combination with Universal Gateway UGE600 this regulator can be controlled over the Internet using SALUS Smart Home app (Online mode). Without Internet connection (Offline mode) thermostat works locally, but its communication with other devices must be done through the coordinating unit – CO10RF. Full version of the PDF manual instruction is available on the website www.salus-controls.eu
Product compliance
EC Directives: 2014/30/EU, 2014/35/EU, 2014/53/EU i 2011/65/EU.
Full information is available on the website
www.saluslegal.com
Safety Information
Use in accordance to national and EU regulations. Use the device as intended,
keeping it in dry condition. Product for indoor use only. Installation must be
carried out by a qualified person in accordance to national and EU
regulations.
Wiring diagram
VS10WRF (white), VS10BRF (black)
- Power Supply: 230V AC (L, N terminals)
- 1, 2 Terminals:
- external air or floor temperature sensor
- external contact (occupancy sensor) – external hot water thermostat (only with KL10RF configuration)
- Montage: 60mm concealed box
VS20WRF (white), VS20BRF (black)
- Power Supply: 4xAAA (alkaline batteries)
- S1, S2 Terminals:
- external air or floor temperature sensor
- external contact (occupancy sensor)
- external hot water thermostat (only with KL10RF configuration)
- Montage: surface mounting (need to remove back cover)
LCD Icon description
- Comfort temperature
- Standard temperature
- Economic temperature
- Automatic mode
- PARTY mode
- Holiday mode
- Antifrost mode
- Temperature unit
- Group controller
- Manual mode / override temp.
- Current / set temperature
- Program number
- AM / PM
- Lock function
- Clock
- Day indicator
- Settings
- Low battery indicator
- External temperature sensor
- Hot water heating
- Modes for Hot Water (KL10RF only)
- Cooling mode ON
- Internet connection indicator
- Gateway wireless connection
- Heating mode ON
Button Functions
Select the type of ZigBee coordinator
Choose a ZigBee coordinator and prepare it to work with iT600 series devices:
- Online – connected to the Internet via the UGE600 gateway
- Offline -the ability to connect to the Internet using the UGE600 gateway
- Offline – without Internet connection with CO10RF coordinator
- Firstly with the selected coordinator need to install devices, which will be controlled by thermostat. Pairing method of each devices is described in the manual instruction of a particular device.
Installation
First start up
Thermostat starts up in a simplified configuration mode. You can choose to pair with:
- KL08RF or KL10RF wiring centre (underfloor heating)
- Thermostatic radiator valve (radiator heating)
Note: Thermostat is set by default as programmable (weekly).
Extended configuration
If the simplified configuration is not suitable, run the expanded configuration by holding 3 keys as below until SEL PROG appears:
Set the theromstat type:
- Programmable (weekly)
- Daily
- Hot Water timer (works only with KL10RF)
After approval of the type of thermostat, choose the type of device to cooperation with:
- Underfloor heating
- Thermostatic radiator valve (radiator heating)
- RX10RF in RX2 mode
- RX10RF in RX1 mode
Pairing with KL08RF / KL10RF wiring centre
Pairing thermostat with TRV in Online mode
WARNING! You can connect up to 6 heads to one thermostat.
Pairing thermostat with TRV in Offline mode
WARNING! You can connect up to 6 heads to one thermostat.
WARNING! Do not use CO10RF coordinator with UGE600 simultaneously.
Pairing thermostat with RX10RF boiler receiver
-
Install the RX10RF boiler receiver according to the instructions attached to the product. Choose proper mode configuration with RX1/RX2 switch inside of RX10RF, then prepare regulator for pairing.
WARNING! In network coordinator can works only with 1 receiver in RX1 mode and 1 receiver in RX2 mode. -
Run thermostat in extended configuration mode and select the device type:
Identification of paired devices
Enter the installer mode, select code “00” and confirm it with button.
LED diodes on the devices connected to the thermostat will start to blink.
Temperature change
To set the temperature, press or , and then confirm it with button.
Note: If thermostat works in AUTO mode, then the overwritten temperature will be maintained until next program. In manual mode and antifrost mode temperature change is permanent.
Factory Reset
If you have made an error, need to change your thermostat parameters or want
to return to the factory settings, please follow steps below.
Note: This action will permanently remove all your settings.
Importer: SALUS Controls Plc Units 8-10 Northfield Business Park Forge
Way, Parkgate, Rotherham S60 1SD, United Kingdom
Distributor: QL CONTROLS Sp. z o.o., Sp.k. Rolna 4, 43-262 Kobielice,
Poland www.salus-controls.eu
Read User Manual Online (PDF format)