Introduction

The KL08NSB wiring centre forms the heart of a Underfloor Heating controls system. It allows easy and quick connection of thermostats and actuators. It has integrated pump and boiler control module and overload protection. KL08NSB wiring centre is adapted to work with NC and NO type actuators (normally closed and normally open). Up to 8 thermostats can be connected to the KL08NSB, while KL04NSB extension allows to connect additional 4 thermostats (12 in total).

Product compliance

This product complies with the essential requirements and other relevant provisions of the following EU Directives: EMC 2014/30/EU, Low Voltage Directive LVD 2014/35/EU, RoHS directive 2011/65/EU. The full text of the EU Declaration of Conformity is available at the following internet address: www.saluslegal.com.

Safety information
Use in accordance with national and EU regulations. Device is intended for indoor use only in dry conditions. Product for indoor use only. Installation must be carried out by a qualified person in accordance to national and EU regulations.

Before attempting to setup and install, make sure that KL08NSB is not connected to any power source. Installation must be carried out by a qualified person. Incorrect installation may cause damage to the wiring centre. The KL08NSB should not be installed in areas where it may be exposed to water or damp conditions.

Technical Information

SALUS KL08NSB 230V 8 Zones Wiring Centre User Manual - Technical
Information

Wiring centre description

  1. Cartridge fuse 5 x 20 mm 12 A
  2. Power supply
  3. NSB function terminals
  4. NC/NO jumper (actuator type)
  5. Delay jumper
  6. Boiler control output
  7. Pump control output
  8. Actuators connection
  9. Serial connector for the KL04NSB extension
  10. Reset button
  11. Thermostats connection

SALUS KL08NSB 230V 8 Zones Wiring Centre User Manual - Product
Overview

1. Fuse

Note: Replace the fuse only when the wiring centre is disconnected from power supply (230 V ~).

Main fuse is located under the housing cover next to power supply terminals and secures the wiring centre and the devices connected to it. Use ceramic tube fast blow 250 V ROHS fuses (5×20 mm) with nominal max current 12,5 A. To replace fuse remove the fuse holder with a flat screwdriver and pull out the fuse.

2. Power Supply

SALUS KL08NSB 230V 8 Zones Wiring Centre User Manual - Power
Supply
Power supply for wiring centre is 230 V ~ 50Hz.

Two wire installation should be made in accordance with the applicable regulations

3. NSB (Night Set Back reduction) function and thermostats grouping
NSB function is activated in non-programmable Salus thermostats of the Expert NSB, HTR, BTR series via external signal. NSB 230 V signal (night-time temperature reduction) is sent via an external timer or programmable thermostat connected to the KL08NSB wiring centre. Non-programmable thermostats are receiving NSB signal and reducing setpoint temperature (by switching to eco mode). All thermostats have to be connected using a 4-wire cable (min. 4 x 0,75 mm2, max. 4 x 1,5 mm2).

NSB function application in combination with thermostats grouping.

SALUS KL08NSB 230V 8 Zones Wiring Centre User Manual - NSB function
application in combination with thermostats grouping SALUS KL08NSB 230V 8 Zones Wiring Centre User Manual - NSB function
application in combination with thermostats grouping

4. NC/NO jumper

Select the type of the thermoelectric actuator connected to the wiring centre: NC ­ actuator normally closed NO ­ actuator normally opened

Jumper position change must be refreshed in the memory by pressing the Reset button (short press).

5. Delay jumper

Boiler off delay time.

Note: Pump (Pump output) and boiler (Boiler output) always starts 3 minutes after receiving the heating signal from any thermostats connected to wiring centre. Pump stops 3 minutes after the last call for heating sent by the thermostat and the heat source (boiler) will turn off after the time set on Delay jumper.

Jumper position change must be refreshed in the memory by pressing the Reset button (short press).

6. Boiler control output

SALUS KL08NSB 230V 8 Zones Wiring Centre User Manual - Boiler control
output

Boiler output – this is a volt free output (COM / NO) that controls the boiler in the heating system. The output closes and the boiler turns on but always after 3 minutes after receiving the heating signal from any of thermostats paired with wiring centre. The output opens and the boiler switches off when the last thermostat stops sending heat demand (after the time set on the Delay jumper).

7. Pump control output

SALUS KL08NSB 230V 8 Zones Wiring Centre User Manual - Pump control
output

Pump output – this is a volt free output (COM / NO) that controls the circulation pump in the heating / cooling system. The output closes (pump starts) always after 3 minutes from the moment of receiving the heating / cooling signal from any of thermostats paired with wiring centre. The output opens (pump stops) 3 minutes after the last demand for heat/cool sent by the thermostat.

8. Actuators connection

The actuator wires should be secured with the self locking connectors in the appropriate zone. Up to 6 actuators with a load of up to 2 Watts each can be connected to a single zone. Should more than 6 actuators be required in a zone use an additional relay to relieve the output.

SALUS KL08NSB 230V 8 Zones Wiring Centre User Manual - Actuators
connection

9. Serial connector for the KL04NSB extension
The Serial connector is used to connect the KL08NSN with the KL04NSB extension module to add functionality and support up to12 zones.

SALUS KL08NSB 230V 8 Zones Wiring Centre User Manual - Serial connector for
the KL04NSB extension

10. Reset button


Reset
– It is used to refresh the data, after switching jumpers 4 or 5.

11. Thermostats connection

• Connecting EXPERT NSB, HTR or BTR series thermostats

SALUS KL08NSB 230V 8 Zones Wiring Centre User Manual - Connecting EXPERT
NSB, HTR or BTR series thermostats

• Connecting a 230 V thermostat to the KL08NSB wiring centre (e.g. SQ610)

SALUS KL08NSB 230V 8 Zones Wiring Centre User Manual - Connecting a 230 V
thermostat to the KL08NSB wiring centre

• Connecting ON/OFF battery-powered thermostat with voltage-free COM / NO output contacts (e.g. 091FL, RT310, RT510)

SALUS KL08NSB 230V 8 Zones Wiring Centre User Manual - Connecting ON OFF
battery-powered thermostat with voltage-free

INSTALLATION

SALUS KL08NSB 230V 8 Zones Wiring Centre User Manual - INSTALLATION 1 to
3 SALUS KL08NSB 230V 8 Zones
Wiring Centre User Manual - INSTALLATION 4 to 6 SALUS KL08NSB 230V 8 Zones Wiring Centre User
Manual - INSTALLATION 7 to 9

PRODUCER:
Salus Limited 6/F, Building 20E, Phase 3, Hong Kong Science Park, 20 Science Park East Avenue, Shatin, New Territories, Hong Kong

IMPORTER:
QL CONTROLS Sp. z o.o. Sp. k.
ul. Rolna 4, 43-262 Kobielice

www.salus-controls.com
SALUS Controls is a member of the Computime Group.
Maintaining a policy of continuous product development SALUS Controls plc reserve the right to change specification, design and materials of products listed in this brochure without prior notice.

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals