ICSTATION Digital Timer Relay AC 85-265V Instructions
- June 6, 2024
- Icstation
Table of Contents
ICStation Digital Timer Relay AC 85-265V
——Instruction
ICStation Digital Timer Relay AC 85-265V 110V 220V 2000W 10A HD LED Dual Time
Display Relay Switch Panel, Timing Delay Cycle ON-OFF control 0-999h(ms)
Repeat
Controller Module
1. There are 4 function buttons, such Up button, Down button, SET button,
OK button.
2. How to set time?
(1) After Short-press the SET button, the T1 digital tube will flash. During
this period, you can set time via the UP, DOWN button. After you finish the
above steps, please short press the SET button again. The T2 digital tube will
flash, you can set the time via the UP, DOWN button. There are 2 ways to save
data, for example, you can wait 6 seconds until the digital tube stop
flashing, the system will save data automatically; you can also short press
the SET Button again to save data.
3. How to set parameters?
Timer Easy Setting Instructions The upper display is referred to as (T1 or PV)
and the lower display is referred to as (T2 or SV). The LED labeled “out”
indicates that the relay contacts are closed when it lights up. Time set mode:
Short Press the SET button and use the up and down buttons to set the time in
the Top display(T1 or PV) short press the set button to set the time displayed
in the bottom display (T2 or SV) short press the set button again to save and
run. Time unit setting Mode. You can set the timer to work in seconds, minutes
or hours: Long press the SET button for 6 seconds or until P0 is displayed in
the top display. Press the up-down buttons to set the time unit mode in the
bottom display (T2 or SV) Top display=P0 bottom display=0 – seconds Top
display=P0 bottom display=1 – minutes Top display=P0 bottom display=2 – hours
There are 5 timer sequence modes: Long press again to set the operating mode
when P0 is displayed press set to display P1 then press the up-down buttons to
display 1 or 2 or 3 or 4 or 5 to set the type of timed operation you want.
P1-0 Load is off until (T1 or PV) time counts down to 0 then the load will
come on and stay on. P1-1 The load comes on as the power button is pressed.
After PV Time the load will go off. P1-2 The load is off for (T1 or PV)(delay
time) then the load switches on and runs for the time set in (T2 or SV) then
switches off until the power switch is pressed to cycle again. P1-3 Load is on
until PV Time runs out Then after SV time runs out the load will come on and
stay on. P1-4 Load is off until (T1 or PV)(Delay) time counts down to 0, then
load comes on until SV time counts down to 0 then the load is off then it
cycles again and again-auto cycle. P1-5 The load is on until (T1 or PV) time
counts down to 0 then powers down and after (T2 or SV)Time counts down to 0
the load will start working and cycle again and again-auto cycle.
Done
P2–0 to P2–5: These parameters are used to switch the display brightness.
P2-OFF: Low power mode. When users set P2 to OFF mode, the system will
automatically turn off the display after 10s. The module will enter the low
power mode, If you want to wake up the module please press any button.
4. What is the Power button’s function?
(1) After finishing all parameter settings, you can press the power button to
save all data and start working. During the working period,if you want to
suspend work, you can press the power button too. If you want to support the
Timing function, you can press the OK button again. (2) Trigger function
again. After finishing working normally, it needs to work again. Short -press
the Power button to re-time. For Example, someone wants that the timer turns
on for 10 seconds, then turn off for 20 seconds, and cycle. The setting method
is as follows:
1. You can long-press the SET Button enter the parameter setting menu. Choose
P0-1 Set T1 10S, then short press SET button saves data. The next step set T2
time 20S.
2. P1-4. After T1 time, the loadstar work (T1 timing), and after T2 time, the
work stop work (T2 timing), and above working mode cycle and repeat.
4. There are 2 different connection ways.
(1) The timer delay and load use different power.
(2) The timer delay and load use the same power