Ring Alarm Range Extender 2nd Generation Z-Wave User Guide
Introduction
Ring Alarm Range Extender is a wireless repeater for the Ring Alarm system which helps to improve the range and reliability of the Ring Alarm network by listening for and repeating network communication between the Ring Alarm Base Station and other Ring Alarm end devices. After installing the RangeExtender and setting up the Range Extender in the Ring app, the devices added to Ring Alarm’s network can utilize the Range Extender’s routing and repeating to communicate effectively with the Base Station. The Ring Alarm Base Station is required to enable Range Extender features and functions within the Ring app.
Notes
- This product can be operated in any Z-Wave™ network with other Z Wave certified devices from other manufacturers. All mains operated nodes within the network will act as repeaters regardless of vendor to increase reliability of the network.
- SmartStart enabled products can be added into a Z-Wave network by scanning the Z-Wave QR Code present on the product with a controller providing SmartStart inclusion. No further action is required and the SmartStart product will be added automatically within 10 minutes of being switched on in the network vicinity.
Installation & Set Up
Ring Alarm Range Extender – Basic Setup & Installation
In-app Setup
- Ensure your Ring Alarm system is disarmed.
- In the Ring app, tap Set Up a Device and find theRange Extender in the Security Devices menu.
- Follow the in-app instructions to complete setup. Plug in the Range Extender to trigger setup mode.
- Tap the button on the front to retry setup mode.
Installation
- The Range Extender plugs into a standard outlet.
- Choose a location for installing your Range Extender. For best coverage, install the Range Extender in an outlet between the Base Station and end devices which may require the use of the Range Extender to improve their ability to communicate with the Base Station.
Note
This product can be operated in any Z-Wave network with other Z-Wave certified
devices from other manufacturers. All mains operated nodes within the network
will act as repeaters regardless of vendor to increase reliability of the
network.
This is a SmartStart enabled product which can be added into a Z-Wave network by scanning the Z-Wave QR Code present on the product with a controller providing SmartStart inclusion. No further action is required and the SmartStart product will be added automatically within 10 minutes of being switched on in the network vicinity. This product can also be operated in any Z-Wave network with other Z-Wave certified devices from other manufacturers.
Z-Wave Instructions
Z-Wave Device Type: Repeater
Role Type : Always On Slave (AOS) GENERIC_TYPE_REPEATER_SLAVE (0x0F)
SPECIFIC_TYPE_REPEATER_SLAVE (0x01)
Ring Alarm Range Extender – Inclusion
Adding Ring Alarm Range Extender to a Z-Wave Network
Ring Alarm Range Extender can be added via SmartStart or Classic inclusion mode.
Note
When prompted for the QR Code or PIN, you may find them on the device, on the box, or on a card inside the box. Keep the device nearby. You’ll be prompted to plug in the Range Extender to power on the device and enter setup mode.
SmartStart Inclusion Steps:
- Initiate the add flow for Security Devices in the Ring mobile application – Follow the guided add flow instructions provided in the Ring mobile application.
- When prompted by the mobile application, scan the QR code found on the package of the Range Extender. The QR code can also be found on the device itself.
- Plug the device into a standard outlet and the device will go into SmartStart inclusion mode. While in this mode, Range Extender can be added to a Z-Wave controller that supports SmartStart. When in SmartStart inclusion mode, SmartStart can be restarted by tapping the button on the front of the device.
Classic Inclusion Steps:
Classic Inclusion should be used if the controller does not support
SmartStart.
- Initiate add flow for Security Devices in the Ring mobile application – Follow the guided add flow instructions provided in the Ring mobile application.
- Select Add Manually and enter the 5-digit DSK PIN found on the package of the Ring Alarm Range Extender or the 5-digit DSK PIN found under the QR code on the device.
- After powering on the device, press and hold the button on the front of the device for ~3 seconds. Release the button and the device will enter Classic inclusion mode which implements both classic inclusion with a Node Information Frame, and Network Wide Inclusion. During Classic Inclusion mode, the green LED will blink three times followed by a brief pause, repeatedly. When Classic inclusion times-out, the device will blink alternating red and green a few times.
LED Behabior for Inclusion | Blink Pattern |
---|---|
SmartStart Started | Green LED three times, repeated after a brief pause |
Classic Inclusion Started | Green LED three times, repeated after a brief pause |
Classic Inclusion Timed-Out | Alternate red and green a few times |
Inclusion Successful (Authenticated S2) | Green LED on solid |
Inclusion Not Successful (Self-Destruct) | Red LED on solid |
Ring Alarm Range Extender – Exclusion
Removing Ring Alarm Keypad from a Z-Wave Network
Exclusion Instructions:
- Initiate remove “Ring Alarm Range Extender” flow in the Ring Alarm mobile application – Select the settings icon from device details page and choose Remove Device to remove the device. This will place the controller into Remove or “Z-Wave Exclusion” mode.
- Locate the pinhole reset button on the back of the device.
- With the controller in Remove (Z-Wave Exclusion) mode, use a paper clip or similar object and tap the pinhole button. The device’s red LED turns on solid to indicate the device was removed from the network.
Ring Alarm Range Extender – Factory Reset
Factory Default Instructions
- To restore Ring Alarm Range Extender to factory default settings, locate the pinhole reset button on the device. This is found on the back of the device after unplugging the device from the outlet.t.
- Using a paperclip or similar object, insert it into the pinhole, press and hold the button down for 10 seconds.
- The device will rapidly blink green continuously for 10 seconds. After about 10 seconds, when the green blinking stops, release the button. The red LED will turn on solid to indicate the device was removed from the network.
Note
Use this procedure only in the event that the network primary controller is
missing or otherwise inoperable.
Wake-Up Notification
Not applicable. Ring Alarm Range Extender is an Always On Slave (AOS) and does
not support Wake Up Command Class.
Z-Wave Command Classes
Command Class | Version |
---|---|
Association | 2 |
Association Group Information | 3 |
Device Reset Locally | 1 |
Firmware Update Meta Data | 5 |
Indicator | 3 |
Manufacturer Specific | 2 |
Multi-Channel Association | 3 |
Powerlevel | 1 |
Security 2 | 1 |
Security 0 | 1 |
Supervision | 1 |
Transport Service | 2 |
Version | 3 |
Z-Wave Plus™ Info | 2 |
Notification | 8 |
Configuration | 4 |
Battery | 2 |
Association Command Class
Group Identifier | Max Nodes | Description |
---|---|---|
1 (Lifeline) | 0x05 | 1. Notification Report |
a. See notification CC section for notifications that are sent
2. Battery Report
3. Device Reset Locally Notification
Configuration Command Class
The device has the following supported configuration parameters.
Parameter Number| Description| Number of Bytes| Default|
Min| Max| Format
---|---|---|---|---|---|---
1| Heartbeats:
This parameter is the number min- utes between heartbeats. Heart- beats are
automatic battery reports on a timer after the last event.| 1| 70 (0x46)| 1
(0x01)| 70 (0x46)| 0x01 Unsigned
2| Number of application level retries attempted for messages either not ACKed
or messages encapsulated via supervision get that did not receive a report.|
1| 1 (0x01)| 0 (0x00)| 5 (0x05)| 0x01 Unsigned
3
| Application Level Retry Base Wait Time Period: The number base seconds used in the calculation for sleeping between retry messages.|
1
| 5 (0x05)| 1 (0x01)| 60 (0x3C)| 0x01 Unsigned
4| This parameter allows a user, via software, to configure the various LED
indications on the device.| 1| 1 (0x01)| 0 (0x00)| 1 (0x01)| enum
5| The number of milliseconds waiting for a Supervisory Report response to a
Supervisory Get encapsulated command from the device before attempting a
retry.|
2
| 1500 (0x5DC)| 500 (0x1F4)| 5000 (0x1388)| 0x01
Unsigned
Notification Command Class, V8
Sensor Condition | Command Class and Value | Association Group |
---|---|---|
AC mains power reconnected | Notification Report | |
Type: 0x08 Power Management State: 0x03 AC mains reconnected | 1 (Lifeline) | |
AC mains power disconnected | Notification Report | |
Type: 0x08 Power Management State: 0x02 AC mains disconnected | 1 (Lifeline) | |
Watchdog Notification | Notification Report Type: System 0x09 | |
State Value: 0x04 System Software Failure State Parameter Value = 0x55 | 1 |
(Lifeline)
Software Fault (Ring)| Notification Report Type: System 0x09
State Value: 0x04 System Software Failure
State Parameter Value = 0xAA (Ring Value for Soft Fault)| 1 (Lifeline)
Software Fault (SDK)| Notification Report Type: System 0x09
State Value: 0x04 System Software Failure
State Parameter Value = 0xA9 (SDK Value for Soft Fault)| 1 (Lifeline)
Software Reset
(Not triggered by failure)| Notification Report Type: System 0x09
State Value: 0x04 System Software Failure State Parameter Value = 0xAC| 1
(Lifeline)
Power On Reset| Notification Report
Type: 0x08 Power Management
Event Parameter: 0x01 Power has been applied| 1 (Lifeline)
Brownout| Notification Report
Type: 0x08 Power Management Event: 0x05 Voltage Drop/Drift| 1 (Lifeline)
Pin Reset (soft reset)| Notification Report Type: System 0x09 State Value:
0x04 System Software Failure State Parameter Value = 0xAB| 1 (Lifeline)
Dropped Frame| Notification Report Type: System 0x09
State Value: 0x04 System Software Failure State Parameter Value = 0xAD| 1
(Lifeline)
Supplier’s Declaration of Conformity – Compliance Information Statement
Unique Identifier: Ring Contact Sensor
Responsible Party and Party issuing Supplier’s Declaration of Conformity
Ring LLC dba Ring
1523 26th Street
Santa Monica, CA 90404 U.S.A.
www.ring.com / Legal@ring.com
FCC Compliance Statement (for products subject to Part 15)
This device complies with Part 15 of the FCC Rules. Operation is subject to
the following two conditions:
(1) This device may not cause harmful interference, and (2) this device must
accept any interference received, including interference that may cause
undesired operation.
NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications.
However, there is no guarantee that interference will not occur in a
particular installation. If this equipment does cause harmful interference to
radio or television reception, which can be determined by turning the
equipment off and on, the user is encouraged to try to correct the
interference by one or
more of the following measures:
- Reorient or relocate the receiving antenna.
- Increase the separation between the equipment and receiver.
- Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
- Consult the dealer or an experienced radio/TV technician for help.
Innovation, Science and Economic Development Canada (ISED) Compliance
This device contains licence-exempt transmitter(s)/ receiver(s) that comply with Innovation, Science and Economic Development Canada’s licence-exempt RSS(s). Operation is subject to the following two conditions:
- This device may not cause interference.
- This device must accept any interference, including interference that may cause undesired operation of the device.
To review your warranty coverage, please visit
www.ring.com/warranty.
© 2020 Ring LLC or its affiliates.
Ring, Always Home, and all related logos are trademarks of Ring LLC or its
affiliates.
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>