AUTOSLIDE M-229E Presence Curtain Sensor Instruction Manual
- June 4, 2024
- AUTOSLIDE
Table of Contents
Operation Instruction
M-229E Presence Curtain Sensor M-229E
Security Guide
**** This device must use protective safety isolation low voltage, and adjust-ment or maintenance must be done by professional installation contractor.
Product Overview
- Decorative cap
- Exposed cover
- Master controller
- Optical surface lens
- LED indicator
- Transmitter window
- El Receiver window
- Wiring terminal
- Function setting
- Sensitivity Adjuster
- Use 5mm flat head screwdriver to adjust the detection range.
Overall Characteristics
- This curtain sensor is specially designed for the automatic sliding door to detect and keep safety. High accuracy.
- Advanced infrared scanning technology. Stable and reliable.
- Have the function of background self-learn. Can learn background automatically when power on. Suit all kinds of occasions.
- Always self-correcting once be influenced by quake, distortion, move, dark, and sunshine. Ensure the sensor can work durable.
Installation
Wiring Diagram of Input and Output
Function Setting
Working mode: High sensitivity or low sensitivity
► High sensitivity: switch 1 up
– The default setting is high sensitivity mode.
► Low sensitivity: switch 1 down
– If the reflectance of the working environment is strong, it should set to
low sensitivity to avoid self-induction or background mistaken.
Scanning Width: Width 78.74’/2000mm or 39.4’/1000mm
► Scan Width 78.74’/2000mm: switch 2 up
– If the scan width is a wide range, it should be set to 78.74’/2000mm.
► Scan Width 39.471000mm: switch 2 down
– If the scan width is a narrow range, it should be set to 1000mm.
Detection Area
B.For narrow scanning range,system
function set to 1000mm
To adjust the angle, remove the main sensor from the cover’s access, make sure
the “Caution Sign” is facing outward before installing back the cover!
Attention
~~~~
Technical Parameter
Power output | AC/ DC 12 ∼30V (—/ +10%) |
---|---|
Type of ray | Infrared light modulation |
Photosource | Infrared 940mm |
Light beam | 8 channel transmit, 8 channel receive |
Quiescent current | 35mA |
Working current | 73mA |
Self-learn time | 1 5s |
Operating display | Standby: blue LED, Detecting: red LED |
Temperature range | -104 °F – 140 °F / -40 °C – 60 °C |
Maximum installation | 2500mm / 98.42′ |
Maximum detection area | 78.7′ / 2000mm NV) x 19.68′ / 500mm (D) |
Hold-Up time | 500ms |
Response time | ≤1 00ms |
Changeover mode | High/Low sensitivity and FA/FB adjustable |
Signal output | Relay, 1 pair contact point optional |
IP | I P54 |
Mechanical behavior | Maximum |
Connection | 0.04 – 0.2 inch2/ 1-1.5 mm25pin terminal |
Shell | ABS |
optical surface | PMMA |
Installation | Exposed or Conceal |
Weight | about 0.32 Pound / 145g |
Dimension | Exposed 7.87’/200mm (L) x 1.9’/49mm (W) x 1.26’/32mm (H) |
Conceal 5.98’/l 52mm (L) x 0.98’/25mm (W) x 1.41’/36mm (H) |