EMOS ZT1520D LED Dustproof Luminaire Instruction Manual
- June 5, 2024
- EMOS
Table of Contents
ZT1520D
ZT1620D
LED Dustproof Luminaire
Part No.| Input Voltage| Power| Color
Temperature
(K)| Luminous
Flux (lm)| Beam
Angle| Lifespan
(hour)| Protection
Rate| Working
Temperature| CRI
(Ra)| ..
Dimensions
---|---|---|---|---|---|---|---|---|---|---
Z11520D| 220-240 V AC| 37W| 4 000 K
(neutral
white)| 53001m| 120°| 50 000 h| IP66| -20-+40 °C| >80| 1220 x 85 x 80 mm
ZT1620D| 53 W| 7 700 lm| 1520 x 85 x 80 mm
LED Dustproof Luminaire
LED luminaire is designed for indoor and outdoor use to be mounted on a solid
base.
Ingress Protection IP66 – for outdoor use.
Housing colour: grey
Diffuser colour: milky
Type | Power | Fixing Hole Distance |
---|---|---|
ZT1520D | 37 W | 850 mm |
ZT1620D | 53 W | 1 200 mm |
Insert Ø 6 mm expansion pipe in the wall, fix the mounting bracket by M4 screw
(see Fig. 2).
Take off the diffuser with LED board (see Fig. 3).
Loosen the nut of the cable gland, put the cable, through the cable gland (see
Fig. 4).
Conect the cable on the terminal block and tighten the cable gland (see Fig.
5).
Connect terminal block with LED board (see Fig. 6).
Close the diffuser (see Fig. 7).
Fix gear tray with the housing (see Fig. 8).
Turn on the switch (see Fig. 9).
WARNING
- Luminaire is suitable entirely for fixed mounting.
- The luminaire can be connected only to the electric distribution network, whose installation and protection complies with the applicable standards.
- Before any manipulation or servicing of the luminaire disconnect the luminaire from AC power. This operation can be carried out only by an authorized person.
- The protection from dangerous contact voltage is ensured by „earthing“.
- In case of any damage to any part of the luminaire, don’t use it.
- LED chips inside the luminaire are not replaceable.
- Don’t change the inner wiring of the luminaire.
- In case of a broken cover don’t use the luminaire and replace the broken cover with new one immediately.
Do not dispose of with domestic waste. Use special collection points for
sorted waste. Contact local authorities for information about collection
points. If the electronic devices would be disposed on landfill, dangerous
substances may reach groundwater and subsequently the food chain, which it
could affect human health.
EMOS spol. s r.o. declares that the LED Dustproof Luminaire is in compliance
with the essential requirements and other relevant provisions of Directive.
The device can be freely operated in the EU. The Declaration of Conformity can
be found at http://www.emos.eu/download.
This product contains a light source of energy efficiency class
TIP:…………….
Servis:……………………..
tel: +386 8 205 17 21
e-mail: reklamacije@emos-si.si