Function / Application

The ThermoSpot laser is a non-contact infrared temperature measuring device with an 8-point laser circle to aid aiming. Non-contact temperature measurement of surfaces is realised by measuring and evaluating the amount of electromagnetic energy in the infrared wavelength range.

General safety instructions

– The device must only be used in accordance with its intended purpose and within the scope of the specifications.
– The measuring tools and accessories are not toys. Keep out of reach of children.
– Modifications or changes to the device are not permitted, this will otherwise invalidate the approval and safety specifications.
– Do not expose the device to mechanical stress, extreme temperatures, moisture or significant vibration.
– The device must no longer be used if one or more of its functions fail or the battery charge is weak.
– Please ensure compliance with the safety regulations set out by local and national authorities with regard to the correct and proper use of the device.

Safety instructions

Using class 2 lasers

Laserliner ThermoSpot Laser - Using class 2 lasers

– Attention: Do not look into the direct or reflected beam.
– Do not point the laser beam towards persons.
– If a person‘s eyes are exposed to class 2 laser radiation, they should shut their eyes and immediately move away from the beam.
– Under no circumstances should optical instruments (magnifying glass, microscope, binoculars)
– Do not use the laser at eye level (1.40…1.90 m).
– Tampering with (making changes to) the laser device is not permitted.

Dealing with electromagnetic radiation

– The measuring device complies with electromagnetic compatibility regulations and limit values in accordance with EMC-Directive 2014/30/EU.
– Local operating restrictions – for example, in hospitals, aircraft, petrol stations or in the vicinity of people with pacemakers – may apply. Electronic devices can potentially cause hazards or interference or be subject to hazards or interference.
– The measuring accuracy may be affected when working close to high voltages or high electromagnetic alternating fields.

Information on maintenance and care

Clean all components with a damp cloth and do not use cleaning agents, scouring agents and solvents. Remove the battery(ies) before storing for longer periods. Store the device in a clean and dry place.

Calibration

The meter needs to be calibrated and tested on a regular basis to ensure it produces accurate measurement results. We recommend carrying out calibration once a year.

Laserliner ThermoSpot Laser - Calibration

4. °C / °F

To set the required temperature unit, press and hold the „°C/°F“ button until the corresponding symbol appears on the display.

Laserliner ThermoSpot Laser - °C , °F

To set the required temperature unit, press and hold the „°C/°F“ button until the corresponding symbol appears on the display.

5. Continuous measurement / Hold

For continuous measurement activate the laser (see figure) and keep the button pressed.

Laserliner ThermoSpot Laser - For continuous measurement activate the
laser

Release the button as soon as the target laser pinpoints the measurement location. The measured value is held.

Laserliner ThermoSpot Laser - Release the button as soon as the target laser
pinpoints

Release the button as soon as the target laser pinpoints the measurement location. The measured value is held.

Measurement procedure notice

This infrared temperature instrument detects the temperature of various surfaces and materials. A built-in sensor head detects the material-specific infrared rays emitted by every object. The amount of these emissions is determined by the material‘s emission coefficient (0 … 1). This instrument is permanently set to an emission coefficient of 0.95, which is applicable to most organic materials as well as plastics, ceramics, wood, rubber and stone. Please ensure that the space between the instrument and surface to be measured is free of disturbances (steam, gas, contamination, glass).

Laser circle

The laser circle is a targeting aid to sight the location for the infrared measurement. Temperature measurement is only performed on the surface within the laser circle.

Laser output

Laserliner ThermoSpot Laser - Laser output

Laserliner ThermoSpot Laser -Laser output

Laserliner ThermoSpot Laser - Technical data

EU directives and disposal

This device complies with all necessary standards for the free movement of goods within the EU.

This product is an electric device and must be collected separately for disposal according to the European Directive on waste electrical and electronic equipment.

Further safety and supplementary notices at: http://laserliner.com/info?an=AFX

Laserliner ThermoSpot Laser - note

Laserliner ThermoSpot Laser - overview

SERVICE

Umarex GmbH & Co. KG

– Laserliner –
Möhnestraße 149, 59755 Arnsberg, Germany
Tel.: +49 2932 638-300, Fax: +49 2932 638-333
info@laserliner.com

Umarex GmbH & Co. KG
Donnerfeld 2
59757 Arnsberg, Germany
Tel.: +49 2932 638-300, Fax: -333
www.laserliner.com

ce, disposal icon

laserliner logo

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Laserliner User Manuals

Related Manuals