zigbee HY368 WiFi Thermostatic Radiator Actuator User Manual

June 6, 2024
zigbee

zigbee HY368 WiFi Thermostatic Radiator Actuator -
logo WIFI Zigbee Radiator Actuator
User Manual

Many thanks for your selection of our products and services, and also for your trust and support to us.

Search for “Smart RM” or “Smart Life” Download the Wifi App with the following icon

https://smartapp.tuya.com/smartroom

  • Add your gateway to the App, then add your radiator actuator to your gateway in the App
  • After the actuator has completed the self-test, press about 3s access setting interface, click or until blink and press , press and hold until rapidly blinking, connection begin.

Note: Your smartphone and gateway must be connected to the same wireless router

Product Specifications

Power: 22 AA 1.5V alkaline b Insulating condition: Normal environment
Display accuracy::0.5℃ Running program: Set per 1 week as a cycle
Probe sensor::NTC(10k)1% Size(mm):53*89.5
Maximum route:4.5mm Range of temperature display::1~70°C
The default range of temperature adjustment:5~35°C Maximum current:90mA
Working environment temperature::-10~60°C Thread size: M30*1.5

Displays & Buttons

NO:

|

Icon

---|---

A

| weekly program, Low battery, Child lock, open window

B

| Holiday mode, Automatic Mode, BOOST Mode, WIFI mode

C

| hour setting minute setting

NO:

|

key

| represent

D

| | 1. short press to set automatic and manual mode.
2. long press 3s to enter setting interface
3. confirm key

E

|

|

represent

F

| | 1. Increasing key
2. long press it into boost mode

zigbee HY368 WiFi Thermostatic Radiator Actuator - figure
1

Install the actuator with the valve and power-on, all of the icons appear, 3s later display program version NO.

zigbee HY368 WiFi Thermostatic Radiator Actuator - figure
2

Continuous click until “Ad” appear, press again, actuator begins self-testing, self-testing is finished, working interface appear

zigbee HY368 WiFi Thermostatic Radiator Actuator - figure
3

Malfunction

error code description
E1 Route is too short: in the adjustment process, the pin was stuck before it

reach the destination of 2mm.
E2| The temperature sensor is open or damaged
| flashing indicates low battery

Note: After malfunction is solved, click to self-test again

Function description

Mode Explain
Holiday mode press 3s enter the setting interface, click or until blink, then

press to confirm and enter temperature setting, press or to adjust the value, press confirms and enters days setting, press or to adjust the value. If you want to cancel holiday mode, press .
Ventilation on and energy saving| Ventilation and energy-saving function is default off, if you want to open this function, please set in advanced options(The default settings will  be restored when the battery is replaced )
BOOST| Press and hold enter BOOST, pressing any key can cancel BOOST mode.

Time setting

Press about 3s access setting interface, click or until blink, press to confirm and appear, press or to adjust hour value, press to confirm and appear, press or to adjust the minute value, press to confirm and the number appears, press or to adjust week value, press to confirm.

Programming mode setting

Press about 3s access setting interface, click or until blink, press enter programming, click until the mode you want blink (5 represent 5+2 days, 6 represent 6+1 days, 7  represent 7 days ), press to enter first time period hour setting, press or to adjust the value, press enters minute setting, press or to adjust the value, press enters temperature setting, press or to adjust the value, press to set second time period, thirdly time period ……
After finishing all time periods, press to save and exit. If you exit before finishing all of the settings, don’t operate, after 5s it will automatically save and return to the working interface.

Programmable(default):

period Default period Default temperature
1 6:00-8:00 20°C
2 8:00-11:30 15°C
3 11:30-12:30 15°C
4 12:30-17:30 15°C
5 17:30-22:00 20°C
6 22:00-6:00 15°C

Advanced options

Press about 3s to access setting interface,click or until set blink, press to access advanced options, press or to change the value, press to set next item, after finishing all, don’t operate, after 10s it will automatically save and exit.

Symbol Setting item Parameter default
AI Measure the temperature correction -9-+9r it
A2 Window ventilation function display• press or

to set
temperature( temperature limit: 5-25r ),
press to confirm and enter valve closing time setting (closing time limit: 5-60 minutes)| (.display means close 2.Valve closing time default 15 minute
A3| Automatic lock if no operation more than 10 minutes| 01 close
1:
open| 0
A4| The minimum limit of the setting temperature| I-16r| 5r
A5| The maximum limit of the setting temperature| 16-70t| 35t
A6| Extend BOOST running time. per press **to increase 100s.| I OOs -900s| 300(display 30)
A7| Check valve opening| 99 mean valve open 100% 5 mean valve open 5% Each increment is 5%|
A8| Temperature hysteresis start setting| 0.5-1.5| 1
A9| Display mode| 0 vertical display I horizontal display| 0
AA| Reset| Display 88, using ****or to change**

to 00, press **to reset, all of the icons appear means reset succeeded**

|

Documents / Resources

| zigbee HY368 WiFi Thermostatic Radiator Actuator [pdf] User Manual
HY368, WiFi Thermostatic Radiator Actuator
---|---

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>