Security Brands 14-500T 433-MHz Keypad User Guide

June 6, 2024
SECURITY BRANDS

Security Brands Logo

Security Brands 14-500T 433-MHz Keypad

QUICK START GUIDE

  1. Carefully unpack box.

  2. Make sure you have all items shown here. (Screwdriver not shown)
    Items

What’s what?

Important components labeled

Keypad Unit

Receiver

  1. Unlock and remove front panel of keypad unit; then using included carriage bolts and hex nuts, attach unit to pedestal as shown.
    Unlock and Remove Front Panel

  2. Using Tek screws, zip ties, or included adhesive mounting pad, attach receiver to inside wall or other surface of gate operator.
    Using Tek Screws

CAUTION!
The receiver is not weatherproof and must be mounted inside a weatherproof enclosure. Internal components can be damaged if exposed to the elements.
Failure to comply will VOID WARRANTY.
WARNING!
AUTOMATIC GATES CAN CAUSE SERIOUS INJURY OR DEATH!ALWAYS CHECK that the GATE PATH IS CLEAR BEFORE OPERATING!
REVERSING or other SAFETY DEVICES SHOULDALWAYS BE USED!

Connect Receiver

Connect Receiver 01

OR

Connect Receiver 02

  1. Remove receiver cover; then hold down Programming button on circuit board for 3 seconds and let go.
    Remove Receiver Cover

  2. Pair keypad unit with receiver by entering battery is connected on keypad unit)
    NOTE: Green arrow indicates “good” tone on keypad unit.

  3. While pairing, keypad unit will beep and flash Once receiver LED goes out and “good” tone is heard on keypad unit, pairing is complete.
    Pairing is Complete

  4. Add Access Code(s) to Channel A.
    (To add multiple codes, enter each of them before pressing pound key)
    Add Access Codes to Channel A NOTE: The Master Code is for programming only and will not trigger the relay.

  5. Make sure gate path is clear; then enter access code on keypad and con firm gate opens. (If keypad locks up, repeat Step 6)
    Gate Path is Clear

INSTALLATION COMPLETE!
Your system is ready to use.

Additional Programming

Delete Code(s)

(To delete multiple codes, enter each of them before pressing pound key)

Additional Programming

NOTE: Green arrow indicates “good” tone on keypad unit. Always wait for good tone before moving on.

Set Unique Keypad ID

(Allows multiple keypad units and receivers to be used. If Keypad ID is changed, keypad unit and receiver must be paired again.)

Set Unique Keypad ID

Change Master Code

Change Master Code

Add Latch Code
Add One-Time-Use Code (Channel A ONLY)

Add One-Time-Use Code

Add Access Code(s) to Channel B

(To add multiple codes, enter each of them before pressing pound key)

Delete All Codes (Cannot Be Undone)
Set Relay Output Time

Set Relay Output Time

Configure Three Strikes, You’re Out

(This feature is designed to deter unauthorized users who enter an incorrect code three times in a row. When this happens, the keypad unit will sound an alarm for 30 seconds, and then it will go into a period of lockdown for a full 90 seconds.)

Check Status

Check Status

Toggle On or Off

Toggle On or Off

NOTE: Green arrow indicates “good” tone on keypad unit. Always wait for good tone before moving on.

Programming Sub Modes

  1. Add Access Code(s) to Channel A
  2. Delete Code(s)
  3. Change Master Code
  4. Configure “Three Strikes, You’re Out”
  5. Add Latch Code
  6. Set Relay Output Time
  7. Add Access Code(s) to Channel B
  8. Add One-Time-Use Code (Channel A)
  9. Pairing and Setting Keypad ID
  10. Delete All Codes

Things to Know

  • *The Star Key ()**
    The star key deletes your current entry.
    If you happen to make a mistake keying in a code, simply press the star key to delete the entire entry and start over.

  • The Pound Key (#)
    The pound key is good for one thing and one thing only: exiting Programming Mode. Whenever you’re in Programming Mode, simply press the pound key to get out.

  • Reset Procedures
    If for some reason the Master Code is forgotten or the unit needs to be reset to factory defaults, two reset procedures are available: Master Reset and Unit Reset .

These procedures can be found in Section B.

Reset Procedures

NOTE: If an error is made during these procedures, an “error” tone will sound and you must start again from the beginning.

Master Reset

(Used if the Master Code is unknown, if the Latch Code is unknown and the unit is in Latch Mode, or if the Sleep Code is unknown and the unit is in Sleep Mode. All other codes will be retained after completing this procedure.)

  • Step 1 – Remove front panel of keypad unit.
  • Step 2 – Disconnect battery.
  • Step 3 – Press and hold Reset Button; reconnect battery; then release Reset Button. Unit will sound one (1) tone. Release Reset Button after you hear tone.
  • Step 4 – Press Star key (*) on keypad three (3) times and wait up to 30 seconds.
  • Step 5 – Reattach front panel onto keypad unit.

The Master Code is now reset to default (1251).

Unit Reset

(Used to reset unit to factory default settings. The Master Code will be retained.)
CAUTION: FOLLOWING THIS PROCEDURE WILL DELETE ALL CODES BUT MASTER CODE!

  • Step 1 – Remove front panel of keypad unit.
  • Step 2 – Disconnect battery.
  • Step 3 – Press and hold Reset Button; reconnect battery; then release Reset Button. Unit will sound one (1) tone. Release Reset Button after you hear tone.
  • Step 4 – Enter Pound (#) Star (*) Pound (#) on keypad. (Unit will sound “good” tone.)
  • Step 5 – Enter 1251 (Master Code) on keypad. (Unit will beep continuously.)
  • Step 6 – While unit is beeping, disconnect and reconnect battery. Unit will then go through power-up procedure.
  • Step 7 – Reattach front panel onto keypad unit.

The unit is now reset to factory default settings. Follow Master Reset to reset Master Code.

FCC Statement

Any Changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment. This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions:

  1. This device may not cause harmful interference, and
  2. This device must accept any interference received, including interference that may cause undesired operation.

Call: 972-474-6390