Description

The CML25 is a dual-use camera as a professional monocular or as an attachment for any type of the standard day scope. NO ZEROING is needed just CLAMP&SHOOT. Expand your detection ability together with your day scope.

Components and Controls

Iray Technology CML25 Thermal Imaging Attachment fig1

All rights reserved and shall not be copied and distributed in any form without written permission

Specifications

Model CML25

Detector Parameters
Resolution| 384×288
Pixel Size| 17um
NETD| ≤50mk
Frame Rate| 50Hz
Optics Parameters
Objective Lens| 25mm
Field of View| 14.9°×11.2°
Diopter Adjustment| -5D~+5D
Detection Range


(Target size:1.7m×1.2m, P(n)=99%)

| ****

916m

Display
Type| OLED
Resolution| 1024×768
Electrical Parameters
Battery| 16340/16650


Max. Battery Life

| 16340(1200mAh)-up to 2hr


16650(2500mAh)-up to 4hr

Functions
Digital Compass| √
Motion Sensor| √
Remote Control| Bluetooth
Physic Parameters
Weight (without batteries)| <290g
Dimension| 125 mm×70mm×48mm
Interface| M30×1.0

Function

Switch on
The CML25 will be switched on after pressing the encoder for 3 seconds, and start up logo on the display screen at the same time.
Switch off
The CML25 will be switched off by long pressing the encoder until the display is off.
Standby
In the normal display mode, enter/exit the standby mode with right rotating the encoder.
Shutter calibration
In the normal display mode, rotate the encoder to the left to perform the shutter correction.
Shortcut menu
Short press the encoder to switch the order of “no menu – Brightness – Image mode – Sharpness – exit shortcut menu”. And rotating encoder can adjust the parameters of each function. If there is no operation within 5 seconds, it will exit the shortcut menu automatically. The functions of shortcut menu are as shown in fig. 4-1
The CML25 will be switched on after pressing the encoder for 3 seconds, and start up logo on the display screen at the same time.
Iray Technology CML25 Thermal Imaging Attachment fig2

● Screen lightness:1~4 lightness level.
● Image mode: W (White hot), B (Black hot), R (Red hot), C (Color).
● Sharpness: 1~4 sharpness level.

Advanced menu
In the normal display mode, long press the rotary encoder for 2 seconds to enter the advanced menu. There are 8 operations as shown in figure 4-2. From top to bottom the options are Ultraclear mode, Bluetooth, Video out, Zeroing type, Battery type, Image calibration, Blind pixel correction, Factory reset. If there is no operation within 5 seconds, it will exit the menu automatically. Or it will exit after long pressing the encoder for 2 seconds.

Table 4-1 CML25 advanced menu function description

Icon Name Function Description Status


| ****


Ultraclear Mode

| ****



On/Off

| In this mode, the image contrast is enhanced, which is suitable for cloudy, rainy, foggy and other harsh

weather conditions

| ****

The icon displays on the status bar.





| ****




Bluetooth

| ****




On/Off

| When Bluetooth is on, it can be operated with the bluetooth remote control or mobile phone APP (please search for connection by

mobile phone within 1 minute,

| ****


The icon displays on the status bar.

 |  |  | otherwise, the bluetooth will be


automatically turned off ).

|
---|---|---|---|---



| ****

Video Output

| ****


On/Off

| ****

Transfer the analog video in pal through the Type-C data cable.

| The icon displays on

the status bar.



| ****

Zeroing Type

| ****


G1/G2/G3/G4

| ****

Up to 4 groups of image calibration data can be saved.

| The icon displays on

the status bar.



| ****

Battery Type

| ****


3V/3.7V

| 3.7v is selected for rechargeable

batteries, and 3V is for normal dry batteries.

| ****


——




|  | ****

Ensure the

|  | Image
 |
Image calibration| ****

position consistency

| ****

Refer to 4.7

| calibration

interface (fig. 4-3)




|  | ****

Calibrate the

|  | Blind pixel
 |
Blind pixel correction| ****

blind pixels on the image

| ****

Refer to 4.8

| calibration

interface(fig. 4-4)



| ****

Factory reset

| ****

Restore factory state

| Y: Confirm,N:Cancel

Then long press M button to save and exit.

| ****


——

Image Calibration
When CML25 is installed on the white light sighting tool as an infrared extension component, if the cross division of the white light sighting is not in the center of the infrared image, the image calibration function can be used to shift the infrared image to ensure the position consistency between the white light image and the infrared image under the 50m .

Operation:

  • Please select the zeroing type before calibration referring to table 4-1 for details.
  • In normal display mode, press option image calibration to enter the image calibration interface (fig. 4-3).
  • Short press the encoder to switch the orientation of X-axis (left-right) and Y-axis (up-down).
  • Rotating the encoder to change the position of screen and fast rotation to start quick shift.
  • After completing calibration, long press the encoder to save and exit the calibration interface.Iray Technology CML25 Thermal Imaging Attachment fig12

Blind Pixel Calibration

  • Under the advanced menu, select the blind element calibration and short press the encoder to enter the blind pixel correction interface (fig.4-4). A cross cursor will appear in the center of the screen.

  • And then, short press the encoder to switch the orientation of X-axis (left-right) and
    Y- axis (up-down), And rotate the encoder to move the cursor up-down or left- right to select the blind pixel.

  • After selecting the blind pixel, press and rotate left the encoder at the same time to correct the blind pixels. Press and rotate again to cancel the setting.

  • Repeat the above operations to continue selecting blind pixel, and the number of corrected blind pixel is shown on the status bar at the bottom of the screen.

  • After the correction is completed, long press the encoder to exit the blind pixel correction.

Compass Calibration

  • Long press the encoder to enter advanced menu.
  • Under the advanced menu, rotate CML25 360 ° 3 laps around the optical axis to enter the compass calibration interface, rotate direction as shown in fig. 4-5.Iray Technology CML25 Thermal Imaging Attachment fig14
  • And then, that a three-axis coordinate system (shown as fig. 4-6) will appear in the center of the screen, ten plane calibration method is used to rotate CML25. It will automatically exit and complete compass calibration after 30s.
  • During the calibration process, long press the encoder to exit the compass calibration interface at any time.Iray Technology CML25 Thermal Imaging Attachment fig15

Preventative Maintenance

Battery Installation

  • The battery power icon is displayed on the status bar ( )and there are five levels of power.
  • When the icon is appeared on the status bar, please change the battery in time so as not to affect the use.
  • It is necessary to power off before replacing the batteries.
  • Because of the great design, there are many choices of the battery, such as 16340. The 16650 battery also can be used with the adapter which will provide longer operating time.
  • Install the battery with the positive pole facing inward and the negative pole outward, as shown in fig. 5-1.
  • Replace and tighten the battery cover clockwise.

Note:

  • After installation, please set the battery type in the advanced menu for the first starting up–choosing 3.7V for rechargeable battery and 3V for disposable battery, otherwise the battery level indication will be inaccurate and may be interrupted during operation.
  • It is not commended to use the disposable batteries (3V) for their short working time.Iray Technology CML25 Thermal Imaging Attachment fig18

Product Cleaning and Maintenance

  • It is prohibited to clean the product body with the cleaning product which is corroded or scratched to optical glass.
  • The product body can be scrubbed with soft cloth dipping certain amount of alcohol.
  • For optical glass devices such as eyepiece lens and objective lens, dust should be blown first, and then use charcoal pen or fat-free cotton dipping non-methylated alcohol to wipe slightly.

Safety Regulation

  • Please use batteries regularly. Do not throw the batteries away or put them into fire after use.
  • Please use standard charger to prevent the product from damages.
  • No short circuit.
  • It is prohibited to expose the product in the high temperature environment more than 60℃.
  • It is prohibited to put the product into fire.

General Trouble Shooting

Table 6-1 CML25 general trouble shooting

Trouble Probable Cause Solution




Image blurring

| ****

The focal length of the objective lens does not meet.

| Adjust the focal length of

objective lens until the image becomes clear.

No image correction for a long


time.

| ****

Perform image correction.


Blurred vision

| ****

Eye relief doesn’t match.

| Adjust the Eye relief until the


image becomes clear.


No analog video output

| Analog video doesn’t open.| Open analog video output.
Data cable doesn’t support data


transmission.

| ****

Replace data cable.




Fail to start up

| Wrong battery installation or low


power.

| Check the battery installation


and battery power.

Insufficient external supply


voltage.

| Check the voltage of external


power supply.


The attachment’s eyepiece is stuck during installation.

| Eye relief mounting limit block isn’t placed parallel to the guide slot and the position is

dislocation.

| ****

Loosen the eyepiece, push it back to square, and then rotate the mounting.

★Please contact with our company relevant personnel as soon as possible if there are some abnormalities that cannot be ruled out. Private demolition is strictly prohibited.

Appendix

User Interface Description

  • Custom interface and data cable are adopted to support Type-C power supply, serial port and PAL video;

  • Support Type-C and battery power supply, support over-voltage and under-voltage reverse connection protection.

  • FCC Caution.

  •  § 15.19 Labeling requirements.
    This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and
    (2) this device must accept any interference received, including interference that may cause undesired operation.

  • § 15.21 Information to user.
    Any Changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment.

  • § 15.105 Information to the user.
    Note: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:

    • Reorient or relocate the receiving antenna.
    • Increase the separation between the equipment and receiver.
    • Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
    • Consult the dealer or an experienced radio/TV technician for help.
  • The device has been evaluated to meet general RF exposure requirement. The de vice can be used in portable exposure condition without restriction.

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Iray Technology User Manuals

Related Manuals