welldana PL-REM-200 LED Allegro DVA RGBW Poollamper User Manual
- July 12, 2024
- welldana
Table of Contents
- welldana PL-REM-200 LED Allegro DVA RGBW Poollamper
- Product Usage Instructions
- Technical specifications
- Box contents
- Installation instructions
- Pairing handheld transmitter & controller
- Troubleshooting
- Declaraction of Conformity
- References
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
welldana PL-REM-200 LED Allegro DVA RGBW Poollamper
Specifications
- Electrical specifications:
- Nominal Input voltage: 230 VAC 50 Hz
- Output voltage on Lamp: 12 VAC 16.7 A
- Output Max output current on Lamp: 14A 250VAC, 14A 30VDC
- Output Max rating Relay Contact A and B: 6A 250VAC, 6A 30VDC
- Resistive Load: 200VA
- Inductive Load: Not specified
- Transformer VA rating: Not specified
- Fuse type: 5x20mm cartridge fuse, 5A 250V slow blow/time lag
- Frequency band transmitter: 868 MHz Class II
- IEC Protection Class: Not specified
Product Usage Instructions
Installation Instructions
Optional: The Switch A & switch B terminals can be used to control auxiliary
circuits like a pool cover or garden lights.
Pairing Handheld Transmitter & Controller
The handheld transmitter is factory-paired. To manually pair, follow
these steps:
- Ensure PL-REM-200 is connected to power.
- Press the pairing button on the controller for at least 5 seconds until LED blinks fast.
- Within 25 seconds, press any button on the handheld transmitter.
- If paired correctly, LED flashes slowly for 5 times. If memory is full, LED flashes 15 times.
Handheld Transmitter Functions
The handheld transmitter functions include toggling lamps ON/OFF, changing
color scenarios, and toggling Output A and B ON/OFF.
Replacing Transmitter Battery
Battery type: A23 12V. Replace the battery following the polarity markings.
Troubleshooting
PROBLEM: The controller doesn’t react to transmitter commands
SOLUTION: Troubleshoot the connection between controller and transmitter.
PROBLEM: The pool lights don’t work
SOLUTION: Check the connections and power supply to the pool lights.
FAQ
Declarations of Conformity
Declarations of conformity for this product can be downloaded from the
House of Duratech website at www.duratech.be.
Contact Details
Propulsion Systems bv Dooren 72
Technical specifications
Electrical specifications
-
Nominal Input voltage 230 VAC 50 Hz
-
Output voltage on Lamp Output 12 VAC
-
Max output current on Lamp Output 16,7 A
-
Max rating Relay Contact A and B
Resistive Load
14A 250VAC
14A 30VDC
Inductive Load
6A 250VAC
6A 30VDC -
Transformer VA rating 200VA
-
Fuse type 5x20mm cartridge fuse
5A 250V slow blow/time lag -
Frequency band transmitter 868 MHz
-
IEC Protection Class Class II
General specifications Controller
-
Ambient air temperature 0°C … +40°C
-
Humidity 10% … 90% RH
non condensing -
Dimensions 195x194x90 mm
-
Weight 3,2 kg
-
Ingress protection rate IP54
Box contents
- PL-REM-200 controller
- Handheld transmitter (DuraLink™ version)
- Spare battery (type A23 12V)
- Screws (4x) & wall plugs (4x)
- Owners’s manual
Installation instructions
- Connect a 230VAC power source to the “220-240VAC INPUT” terminal
- Connect the swimming pool lights to the “Lamp 12VAC output” terminal
Make sure the total load of pool lights does not exceed 200Watt
Optional: The “Switch A” & “switch B” terminals can be used to control auxiliary circuits like a pool cover or garden lights.
Pairing handheld transmitter & controller
The handheld transmitter is already paired in the factory and ready to use. The PL-REM-200 can pair with up to 6 handheld transmitters. In case a problem arises, the pairing process can be done manually:
Manual Pairing process:
Make sure the PL-REM-200 is connected to a power source.
-
Press the pairing button on the small circuit board, inside the controller for at least 5 seconds.
–> The LED will start to blink fast -
Within 25 seconds, press any button on the handheld transmitter.
–> If the transmitter is paired correctly, the LED will flash slowly for 5 times
–> If the PL-REM-200 pairing memory is full, the LED will flash 15 times.
This means 6 handheld devices have already been paired.
To unpair all handheld transmitters with the controller: Push the pairing
button for at least 5 seconds, then do nothing for at least 25 seconds.
–> The pair memory will be erased – the green LED will flash 5x on/off.
If no transmitters are paired, the PL-REM-200 will accept messages from any
transmitter!
Handheld transmitter functions
Replacing transmitter battery
- Remove the philips head screw and open the transmitter
- Replace the battery, respecting the polarity Battery type: A23 12V
Troubleshooting
Declaraction of Conformity
Declarations of conformity covering this product are available for download from the House of Duratech website: www.duratech.be
Contact details
Propulsion Systems bv Dooren 72
1785 Merchtem, Belgium
Tel +32 2 461 02 53
www.duratech.be
info@propulsionsystems.be
We reserve the rights to change all or part of the contents of this document without prior notice