GRANDSTREAM GRP2670 IP Phone User Manual
- June 6, 2024
- GRANDSTREAM
Table of Contents
GRP2670
Carrier-Grade HD IP Phones
Quick Installation Guide
TheThe GRP2670 is not pre-configured to support or carry emergency calls to
any type of hospital, law enforcement agency, medical care unit (“Emergency
Service(s)”) or any other kind of Emergency Service. You must make additional
arrangements to access Emergency Services. It is Your responsibility to
purchase a SIP-compliant Inter-net telephone service, properly configure the
GRP2670 to use that service, and periodically test your configuration to
confirm that it works as You expect. If You do not do so, it is Your
responsibility to purchase traditional wireless or landline telephone services
to access Emergency Services.
GRANDSTREAM DOES NOT PROVIDE CONNECTIONS TO EMERGENCY SERVICES VIA THE
GRP2670. NEITHER GRANDSTREAM NOR ITS OFFICERS, EMPLOYEES, OR AFFILIATES MAY BE
HELD LIABLE FOR ANY CLAIM, DAMAGE, OR LOSS, AND YOU HEREBY WAIVE ANY AND ALL
SUCH CLAIMS OR CAUSES OF ACTION ARISING FROM OR RELATING TO YOUR INABILITY TO
USE THE GRP2670 TO CONTACT EMERGENCY SERVICES, AND YOUR FAILURE TO MAKE
ADDITIONAL ARRANGEMENTS TO ACCESS EMERGENCY SERVICES IN ACCORDANCE WITH THE
IM-MEDIATELY PRECEDING PARAGRAPH.
The GNU GPL license terms are incorporated into the device firmware and can be
accessed via the Web user interface of the device at http(s)://IP/gpl_license.
To obtain a CD with GPL source code information please submit a written
request to info@grandstream.com
PRECAUTIONS:
WARNING: Please DO NOT power cycle the GRP2670 during system boot up or
firmware upgrade. You may corrupt firmware images and cause the unit to
malfunction.
WARNING: Use only the power adapter included in the GRP2670 pack-age.
Using an alternative non-qualified power adapter may possibly damage the unit.
OVERVIEW:
GRP2670 is a next-generation enterprise IP Phone featuring, 7″ (1024×600) Capacitive touch TFT color LCD, USB port,1000M network ports, integrated PoE, Wi-Fi and Bluetooth support, 5-way conference, and Electronic HookSwitch (EHS). The GRP2670 de-livers superior HD audio quality, rich and leading edge telephony features, protection for privacy, and broad interoperability with most 3rd party SIP devices and leading SIP/NGN/IMS platforms. GRP2670 is the perfect choice for enterprise users looking for high quality, feature-rich multi-line executive IP phone with advanced functionalities and performance.
PACKAGE CONTENTS: PHONE SETUP
*Installing the phone (Wall Mount sold separately):**
- Attach the wall mount spacers to the slot for wall mount spacers on the back of the phone.
- Attach the phone to the wall via the wall mount hole.
- Pull out the tab from the handset cradle (See figure below).
- Rotate the tab and plug it back into the slot with the extension up to hold the handset while the phone is mounted on the wall (See figure below).
Installing the phone (Phone Stand) : For installing the phone on the table with the phone stand, attach the phone stand to the bottom of the phone where there is a slot for the phone stand. (Upper half, bottom part). CL/3
CONNECTING THE PHONE:
To set up the GRP2670, follow the steps below:
1. Connect the handset and main phone case with the phone cord.
2. Connect the 12V DC output plug to the power jack on the phone; plug the
power adapter into an electrical outlet. If the PoE switch is used in step 3,
this step could be skipped.
3. Network connection is possible via two methods which are described below.
Using Ethernet:
• Connect the LAN port of the phone to the RJ-45 socket of a hub/switch or a
router (LAN side of the router) using the Ethernet cable. Using WIFI:
• On the LCD menu, navigate to “System—.WiFi settings” and enable WiFi.
• Select “Scan” and GRP2670 will automatically start scanning within the
range. A list of WiFi networks will be displayed. Select the desired network,
and if required, enter the correct password to connect.
4. The LCD will display provisioning or firmware upgrade information. Before
continuing, please wait for the date/time display to show up.
5. Using the phone embedded web server or keypad configuration menu, you can
further configure the phone using either a static IP or DI-ICE
PHONE DESCRIPTION:
PHONE CONFIGURATION:
Configure the GRP2670 using a Web Browser:
- Ensure your phone is powered up and connected to the Internet.
- Press and hold the “UP” button for 3 seconds to see the IP address
- Type the phone’s IP address in your PC browser.
- Enter the admin’s username and password to access the configuration menu. (The factory default username is “admin” while the default random password can be found on the sticker at the back of the unit).
Configure the GRP2670 using the Keypad:
1. Make sure the phone is idle.
2. Press the MENU key to access the keypad MENU to configure the phone.
3. Select MENU Phone SIP Account to configure settings for SIP Proxy,
Outbound Proxy, SIP User ID, SIP Auth ID, and SIP Password.
4. Follow MENU options to configure the basic features of the phone. For
example, the IP address if using a static IP. For details, please check the
GRP2670 User Manual. 5. Please contact your ITSP for additional settings that
may be necessary to configure the phone.
Refer to online documents and FAQ for more detailed information:
http://www.grandstream.com/our-products
This product is covered by one or more of the U.S. patents (and any foreign
patent counterparts thereto) identified at
www.cmspatents.com.
For certification information, please refer to User Manuals:
http://www.grandstream.com
Common part:
This equipment complies with radiation exposure limits set forth for an
uncontrolled environment. This transmitter must not be co-located or operating
in conjunction with any other antenna or transmitter. This equipment should be
installed and operated with a minimum distance of 20cm between the radiator&
your body.
The earpiece is easy to absorb small objects, please take care to avoid
scratching.
U.S. FCC Part 68 Regulatory Information
This equipment complies with Part 68 of the FCC rules. Located on the
equipment is a label that contains, among other information, the ACTA
registration number and ringer equivalence number (REN.) If requested, this
information must be provided to the telephone company.
The REN is used to determine the number of devices that may be connected to
the telephone line. Excessive REN’s on the telephone line may result in the
devices not ringing in response to an incoming call. In most, but not all
areas the sum of the REN’s should not exceed five (5.0). To be certain of the
number of devices that may be connected to the line, as determined by the
total REN’s contact the telephone company to determine the maximum REN for the
calling area.
This equipment cannot be used on the telephone company-provided coin service.
Connection to Party Line Service is subject to State Tariffs.
If this equipment causes harm to the telephone network, the telephone company
will notify you in advance that temporary discontinuance of service may be
required. If advance notice isn’t practical, the telephone company will notify
the customer as soon as possible. Also, you will be advised of your right the
file a complaint with the FCC if you believe it is necessary. The telephone
company may make changes in its facilities, equipment, operations, or
procedures that could affect the operation of the equipment. If this happens,
the telephone company will provide advance notice in order for you to make the
necessary modifications in order to maintain uninterrupted service.
If the trouble is causing harm to the telephone network, the telephone company
may request you to remove the equipment from the network until the problem is
resolved. This equipment uses the following USOC jacks: RJ45C. It is
recommended that the customer install an AC surge arrester in the AC outlet to
which this device is connected. This is to avoid damaging the equipment caused
by local lightning strikes and other electrical surges.
If trouble is experienced with this equipment, please contact (Agent in the
US): Company Name: Grandstream Networks, Inc. Address: 126 Brookline Ave, 3rd
Floor Boston, MA 02215, USA
Tel: 1-617-5669300
Fax: 1-617-2491987
U.S. FCC Part 15 Regulatory Information
This device complies with part 15 of the FCC Rules. Operation is subject to
the following two conditions:(1) this device may not cause harmful
interference, and (2) this device must accept any interference received,
including interference that may cause undesired operation.
Any changes or modifications not expressly approved by the party responsible
for compliance could void the users authority to operate the equipment.
Note: This equipment has been tested and found to comply with the limits
for a Class B digital device, pursuant to part 15 of the FCC Rules. These
limits are designed to provide reasonable protection against harmful
interference in a residential installation. This equipment generates, uses and
can radiate radio frequency energy and, if not installed and used in
accordance with the instructions, may cause harmful interference to radio
communications. However, there is no guarantee that interference will not
occur in a particular installation. If this equipment does cause harmful
interference to radio or television reception, which can be determined by
turning the equipment off and on, the user is encouraged to try to correct the
interference by one or more of the following measures:
—Reorient or relocate the receiving antenna.
—Increase the separation between the equipment and receiver.
—Connect the equipment into an outlet on a circuit different from that to
which the receiver is connected.
—Consult the dealer or an experienced radio tv technician for help.
Canada Regulatory Information
Radio equipment Operation of 5150-5250 MHz is restricted to indoor use only.
This device contains license-exempt transmitter(s)/receiver(s) that comply
with Innovation, Science, and Economic Development Canada’s license-exempt
RSS(s). Operation is subject to the following two conditions:
- This device may not cause interference.
- This device must accept any interference, including interference that may cause undesired operation of the device.
CAN ICES-3 (B)/NMB-3(B)
Terminal equipment
This product meets the applicable Innovation, Science, and Economic
Development Canada technical specifications. The Ringer Equivalence Number
(REN) indicates the maximum number of devices allowed to be connected to a
telephone interface. The termination of an interface may consist of any
combination of devices subject only to the requirement that the sum of the
RENs of all the devices does not exceed five.
Grandstream Networks, Inc.
126 Brookline Ave, 3rd Floor Boston, MA 02215 USA Voice:
617-566-9300 Fax:
617-249-1987
www.grandstream.com
In the UK and EU member states. operation of 5150-5350 MHz is restricted to
indoor use only.
`04rarnatcy -arra W14iNcrfrurrudiruri, Thrcrs
www.grandstream.com
Grandstream Networks, Inc.
126 Brookline Ave, 3rd Floor Boston, MA 02215 USA Voice:
617-566-9300 Fax:
617-249-1987
www.grandstream.com
In the UK and EU member states. operation of 5150-5350 MHz is restricted to indoor use only.
For Warnatcy -arra W14iNcrfrurrudiruri www.grandstream.com
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>