HACH 2100Q/DR 1900 Modules Instructions
- June 6, 2024
- HACH
Table of Contents
- HACH 2100Q/DR 1900 Modules Instructions
- Specifications
- General information
- Safety information
- Use of hazard information
- Precautionary labels
- Product overview
- Power module components
- USB module components
- USB+Power module components
- N O T I C E
- N O T I C E
- N O T I C E
- Module installation
- Operation
- Send data to the computer (DR 1900)
- Print stored data
- Printer setup
- Update firmware
- [Connect the USB+Power or USB module to a USBBarcode scanner]](#Connect+the+USB%2BPower+or+USB+module+to+a+USBBarcode+scanner%5D)
- Replacement parts and accessories Accessories
- Read More About This Manual & Download PDF:
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
HACH 2100Q/DR 1900 Modules Instructions
Specifications
Specifications are subject to change without notice.
Specification | Details |
---|---|
Power requirement | AC 100–240 V, 50/60 Hz to 9V/2A DC (with power or USB |
+Power module)
4 AA alkaline batteries
Rechargeable NiMH (for use with USB+Power module)
Operating conditions| 0 to 40 °C (32 to 104 °F)
General information
Revised editions are found on the manufacturer’s website.
Safety information
The manufacturer is not responsible for any damages due to misapplication or
misuse of this product including, without limitation, direct, incidental and
consequential damages, and disclaims such damages to the full extent permitted
under applicable law. The user is solely responsible to identify critical
application risks and install appropriate mechanisms to protect processes
during a possible equipment malfunction.
Please read this entire manual before unpacking, setting up or operating this
equipment. Pay attention to all danger and caution statements.
Failure to do so could result in serious injury to the operator or damage to
the equipment.
Make sure that the protection provided by this equipment is not impaired.
Do not use or install this equipment in any manner other than that specified
in this manual.
Use of hazard information
Indicates a potentially or imminently hazardous situation which, if not
avoided, will result in death or serious injury.
Indicates a potentially or imminently hazardous situation which, if not
avoided, could result in death or serious injury.
Indicates a potentially hazardous situation that may result in minor or
moderate injury.
Indicates a situation which, if not avoided, may cause damage to the instrument. Information that requires special emphasis.
Precautionary labels
Read all labels and tags attached to the instrument. Personal injury or damage
to the instrument could occur if not observed. A symbol on the
instrument is referenced in the manual with a precautionary statement.
| This symbol, if noted on the instrument, references the instruction manual
for operation and/or safety information.
---|---
| This symbol indicates that a risk of electrical shock and/or electrocution
exists.
| Electrical equipment marked with this symbol may not be disposed of in
European public disposal systems after 12 August of 2005. In conformity with
European local and national regulations (EU Directive 2002/96/EC), European
electrical equipment users must now return old or end-of-life equipment to the
Producer for disposal at no charge to the user.
Note: For return for recycling, please contact the equipment producer or supplier for instructions on how to return end-of-life equipment, producer- supplied electrical accessories, and all auxiliary items for proper disposal.
Product overview
There are three types of modules that can be used with the 2100Q, 2100Qis and
DR 1900: the power module, the USB+Power module and the USB module. The meter
can be powered by an AC-DC power
adaptor with the power module and the USB+Power module. The USB +Power module
and the USB module are also used for communication with a PD-24 Citizen
printer, USB-Barcode scanner and computer. The module firmware can be updated
with a file downloaded from the computer.
Power module components
The manufacturer recommends to use only the supplied power supply (LZV803).
Refer to Figure 1 to make sure that all components have been received.
If any of these items are missing or damaged, contact the manufacturer or a
sales representative immediately.
_ Figure 1 Power module components
_
1 Power module1| 2 AC adapter plugs (EU/USA/UK/AUSTRALIA) and AC- DC
power supply
---|---
USB module components
Refer to Figure 2 to make sure that all components have been received.
If any of these items are missing or damaged, contact the manufacturer or a
sales representative immediately.
_ Figure 2 USB module components
_
1 USB module1 | 3 USB cable, type A receptacle to USB mini B plug |
---|
2 USB cable, type A plug to USB mini B plug
1 Not available in all regions
USB+Power module components
N O T I C E
The manufacturer recommends to use only the supplied power supply (LZV803).
Refer to Figure 3 to make sure that all components have been received.
If any of these items are missing or damaged, contact the manufacturer or a
sales representative immediately.
_ Figure 3 USB+Power module components
_
1 USB cable, type A plug to USB mini B plug | 3 USB+Power module1 |
---|---|
2 USB cable, type A receptacle to USB mini B plug | 4 AC adapter |
plugs (EU/USA/UK/AUSTRALIA) and AC- DC power supply
1 Not available in all regions
Potential fire hazard. Use only alkaline or nickel metal hydride batteries (NiMH) in the meter. Other battery types or incorrect installation can cause a fire. Never mix battery types in the meter.
N O T I C E
The battery compartment is not waterproof. If the battery compartment becomes wet, remove and dry the batteries and dry the interior of the compartment. Check the battery contacts for corrosion and clean them if necessary.
N O T I C E
When using nickel metal hydride (NiMH) batteries, the battery icon will not indicate a full charge after freshly charged batteries have been inserted (NiMH batteries are 1.2 V versus 1.5 V for alkaline batteries). Even though the icon does not indicate complete charge, 2300 mAH NiMH batteries will achieve 90% of instrument operation lifetime (before recharge) versus new alkaline batteries.
N O T I C E
To avoid potential damage to the meter from battery leakage, remove the meter
batteries prior to extended periods of non-use.
Refer to the Instrument User Manual for additional information about battery
installation.
Module installation
Refer to the numbered procedure steps for instructions on how to install the power module, USB module and USB+Power module.
Operation
Send data to the computer (2100Q)
Data that has been downloaded to the USB+Power module or USB module can be transferred and stored to a computer. The data will be formatted as an XML file.
-
Push DATA MANAGEMENT>Send Data Log.
-
Select an option.
Option Description
Log
Send Data All data is sent to the USB+Power/USB module.
Filter Data Data is filtered by:
Data Type—All Logs, Reading Log, Calibration Log and
Verify Cal Log
Time Interval—All Logs, Last Reading, Current Day, Current
Week and Current Month
Sample ID—Off or Sample ID
Operator ID—Off or Operator ID
a. Select Send Data to send all data to the USB+Power/USB module.
b. Select Filter Data. Make a choice of the data to transfer and push Exit. Select Send Data to send the selected data to the USB +Power module.
A progress bar will show the transfer status and shows “Transfer
Complete” when the data is successfully sent to the USB +Power/USB module. -
Remove the USB+Power/USB module from the meter.
Note: Do not connect the USB+Power/USB module to the computer when the module is still connected to the meter. -
Plug the USB cable, type A, to the USB+Power/USB module and connect the USB+Power/USB module to the PC.
Note: The USB+Power/USB module works like a USB storage device. Navigate through Windows Explorer to find the USB+power module. -
Open the folder “datalog”. Find the data file.
The file name will be formatted as: Year_Month_Day_Hour_Minute. xml. -
Save the data file to a location on the computer.
A progress bar will show the transfer status and shows “Transfer Complete” when the data is successfully sent to the USB +Power/USB module. -
Open a spreadsheet program to view the data.
A progress bar will show the transfer status and shows “Transfer
Complete” when the data is successfully sent to the USB +Power/USB module.
Send data to the computer (DR 1900)
Data that has been downloaded to the USB+Power or USB module can be transferred and stored to a computer. The data will be formatted as an CSV file.
-
Push SETTINGS>Data Management>Send Data. All data is sent to the USB+Power/USB module.
The reading screen shows “Transfer Complete” when the data is successfully sent to the USB+Power/USB module. -
Remove the USB+Power/USB module from the meter.
Note: Do not connect the USB+Power/USB module to the computer when the module is still connected to the meter. -
Plug the USB cable, type A, to the USB+Power/USB module and connect the USB+Power/USB module to the PC.
Note: The USB+Power/USB module works like a USB storage device.
Navigate through Windows Explorer to find the USB+power/USB module. -
The data file is located under the root directory.
The file name will be formatted as: LOGYear_ Month_Day_Hour_Minute_Second.txt. -
Save the data file to a location on the computer.
-
Open a spreadsheet program to view the data.
Print stored data
All data can be sent to a printer. The PD-24 Citizen Printer is compatible with the meter and is FCC Part 15B, Class B compliant. Other printers may not be compatible.
Printer setup
Refer to the documentation supplied with the printer to select the USB interface. Print data
-
Turn off the meter. Install the USB+Power/USB module to the meter and to AC power.
-
Connect the printer to the USB+Power/USB module with the USB cable supplied with the printer and the special USB cable adapter supplied with the module.
-
Connect the printer to power and turn the printer on.
-
Push the ON/OFF key to turn the meter on. The meter automatically detects when the printer is installed.
Note: 2100Q: After a reading is taken, the data is automatically transferred to the printer when the Auto-print data is selected. -
2100Q: Push DATA MANAGEMENT>Send Data Log.
-
DR 1900: Push SETTINGS>Data Management>Print Data.
-
Select an option
Option Description
Send Data Log/Send Data Data is sent directly to the printer.
Filter Data (2100Q only)
Select specific data and then press Send Data.
Data type—All Logs (Default setting), Reading Log,
Calibration Log or Verify Cal Log
Time Interval—All Logs (Default setting), Last Reading,
Current day, Current week or Current Month
Sample ID
Operator ID
Note: Sample ID and Operator ID are disabled when no ID was created.
Update firmware
Locate the firmware upgrade file on the product website. Save the file from the website to the PC.
-
Connect the USB+Power or USB module to the PC.
-
2100Q: Copy the update file “UI_TP_TURB.blk” to the USB +Power/USB module.
-
DR 1900: Copy the update file “fw.pzip” and “config.pzip” to the USB+Power/USB module folder: “dr1900_update”.
-
2100Q: Unzip the file “Ing.zip” and copy the folder “Ing” to the USB +Power/USB module.
-
Disconnect the USB+Power/USB module from the PC.
-
Plug the USB+Power/USB module into the meter.
-
2100Q: Press and hold the POWER key for 4 seconds.
-
DR 1900: Set the power to off. Connect the module to external power, then set the power to on.
-
The update process starts. The display shows “Updating meter to
”. After this update, the language update starts automatically. The display shows “Updating files…” and then shows
“Update complete” when the update is done. -
2100Q: Press DONE. Select the applicable language.
-
DR 1900: Set the current time.
-
Press OK. The meter is ready to use
Connect the USB+Power or USB module to a USBBarcode scanner]
If a USB-Barcode handset scanner is connected, Sample IDs and Operator IDs can also be scanned.
- Connect the USB-Barcode scanner cable to the adapter cable (USB A receptacle to USB B mini B plug).
- Connect the adapter cable to the USB+Power/USB module.
- Push the POWER key to turn the meter on.
- Select between two options:
a. Scan the appropriate barcode. A new sample ID is created and automatically stored with the next reading.
b. Select DATA MANAGEMENT and then Sample ID or Operator ID. Select Create New ID and scan the appropriate barcode. The new ID is automatically stored.
Replacement parts and accessories Accessories
Description | Quantity | Item no. |
---|---|---|
USB+Power module with universal power supply, USB cable (2x) | 1 |
LZV813.99.000021
Power module with universal power supply| 1| LZV804.99.000021
USB module with USB cable (2x)| 1| LZV949.99.000021
Printer, Citizen PD-24 USB printer, 120– 220 VAC| 1| 2960100
Printer paper for Citizen PD-24, thermal| 5/pkg| 5836000
USB-Barcode Scanner (handset scanner)| 1| LZV566
Power supply, 110-240 VAC| 1| LZV803
Module cover| 1| LZV824
Connector cover, USB+Power module| 1| LZV825
Connector cover, power module| 1| LZV826
Standard USB Cable with Mini USB connector| 1| LZV818
Special USB Cable adapter| 1| LZV819