ELING 106-00305-01 Multi Functional Gauge with LCD Hour Meter Owner’s Manual

June 1, 2024
ELING

ELING 106-00305-01 Multi Functional Gauge with LCD Hour Meter

Product Information

Specifications

  • Operating Voltage: 9~32VDC
  • Operating Current: 150mA
  • Operating Temperature: -30~+75°C
  • Storage Temperature: -40~+85°C

Product Usage Instructions

Installation

Before installation, follow these steps:

  1. Open a hole in the panel with a diameter of 85~87mm.
  2. Ensure there is a space of 70mm behind the panel.

GPS Installation

For GPS installation:

  • GPS should be installed in front or in reverse based on the requirements.
  • Avoid using materials that can shield GPS signals.

Multifunction Usage

For multifunction usage:

  • Range of tachometer: 0~9999 RPM
  • Range of speed: 0~999 km/h, MPH, Knots
  • Range of water temperature: 40~120°C (104~248°F)
  • Range of fuel: 0-100%

FAQ

Common Issues and Solutions

Error Codes:

  • E01: GPS signal not found.
  • E02: GPS signal lost midway.
  • E03: Device malfunction.

Operation Tips:

  • To enter setting mode, hold the button for 3 seconds.
  • To switch the speed unit, quick press the MODE button.
  • Trip mileage will be reset when the power is off by default.

OWNER’S MANUAL

  • Pic A:Before installation , firstly ,to open a hole (Dia:85~87mm) of the panel, make sure there is a space with (70mm backyard of panel) as well
  • PicB: Put the gauge in the hole
  • Pic C: Using M4 nut and C type bracket to seal up the gauge

Specification

  • Operating Voltage: 9~32VDC,
  • Operating current: ≤150mA;
  • Operating temperature:- 30~+75℃
  • Storage temperature:- 40~+85℃。

ELING-106-00305-01-Multi-Functional-Gauge-with-LCD-Hour-Meter-
FIG-3

PRODUCT OVERVIEW

ELING-106-00305-01-Multi-Functional-Gauge-with-LCD-Hour-Meter-
FIG-4

GPS installation instructions

ELING-106-00305-01-Multi-Functional-Gauge-with-LCD-Hour-Meter-
FIG-2

Multifunction Instruction

  1. Range of tacho:0~9999 RPM
  2. Range of speed:0~999 km/h MPH, Knots
  3. Range of water temp :40~120℃(104~248F)
  4. Range of fuel: 0-100%
  5. Range of pressure:0~5bar 0~10bar 0-100Psi/0-150Psi
  6. Range of ODO: 0~99999.9 km, miles, knots
  7. Range of hours:0~99999.9 hours
  8. Range of trip:0~999.9 km/h, MPH,Knots
  9. Range of Volt: 8-32V

Speed ratio :

  1. Range of speed ratio:1.0-300.0;
  2. If your transmitter is installed on the flywheel,come from w point signal, the ratio value is equal to half electrodeplate (Poles/2). If it is the gasoline engine, the speed ratio is equal to the number of cylinders (cylinder/2)

Typ tting reference:

ELING-106-00305-01-Multi-Functional-Gauge-with-LCD-Hour-Meter-
FIG-6

Wires Connecting

ELING-106-00305-01-Multi-Functional-Gauge-with-LCD-Hour-Meter-
FIG-5

GPS Speedometer

  1. Power on, to finish the connection as in picture E
    Firstly, the GPS speedometer will start searching GPS signal input, within 0 to 300 seconds counting.If the device cannot find any GPS signal within 300 seconds, there will be an error code “E01” indicating. If the device loses its GPS signal input, then it will restart to search again, if it cannot found any GPS sign input in the following 300 seconds, there will be an error code “E02” indicating. But, generally, the device will read GPS signal input and then be ready for work.

  2. The speed unit(MPH(default)→Km/h → Knots) could be switched by quick pressing the MODE button, then recorded.
    TRIP: Subtotal mileage, data wil be reset when power off as default ODO: Total mileage, data will be recorded when power off

  3. Error Code
    E01 : The GPS signal could not be found E02 : The GPS signal was lost midway. E03 : Malfunction of the device

Operation

  1. Button.
    a. Firstly, hold the button (≥3 seconds) to entry setting mode, Hourmeter parts: Y-XXX.X digital Y, )to quick press(≤2 seconds) the Set button to have the digital Y indicating from 0~14 cycle
    b. At this time, user holds the Mode button again, the digital XXX.X will increase; If user releases then hold the Mode button again, the digital XXX.X will decrease repeatedly.
    c. Please refer to the below parameter group,and set all the features/value /functions required, all data will be recorded will be recorded if you release both Mode and Set buttons (≥3 seconds)
    d.Quick press the Mode button to switch the speed unit MPH(default) →Km/h→Knots
    Example
    Value 2-0001– Water temperature gauge
    Value 1-096.0– Speed ratio was set as 96.0

Parameter Group

ELING-106-00305-01-Multi-Functional-Gauge-with-LCD-Hour-Meter-
FIG-7

NOTE :

  1. The icon will be flickering when the alarm was triggered
  2. For volmeter: a, 12V system — the icon will be flickering when the input voltage ≤ 11.3 V b, 24V system — the icon will be flickering when the input voltage ≤ 22.6 V
  3. The device could identy its input power is 12V or 24 V automatically

Read User Manual Online (PDF format)