SEID-3I0A(G) User manual
SEID-3I0A(G) User Manual V1.0
Functions and features
Special development environment
LM studio, a configuration software independently developed by RISING, has the following characteristics:
- Language model for embedded real-time control system development
- High security and confidentiality
- The modular structure is adopted
Short entry cycle, easy to use
Adapt to the harsh environment
- Can be used in a cold and hot environment: – 20 -C7 low temperature, 65 thigh temperature
- Anti-reverse connection design of power supply
- It is suitable for strong vibration, dusty rain, lightning, and another environment of field operation
Product appearance structure-function description
Product appearance
Product installation size
NAME | FUNCTION | Pin | NOTE |
---|---|---|---|
Analog input | Power | ||
input | AI 1.1 | J3-1 | Analog voltage AI_ V sampling: sampling range 0-10V DC, |
sampling
accuracy 0.5%, resolution 0.025%;
AI_V_2| J3-9
Resistor
input| AI R 1| J2-10| 0 2000, Accuracy 1%
AI_R_2| J2-13
Digital
output| PWM| PWM_1| J3-3| PWM output: frequency:
50 ‘‘’ 2kHz, current: 0 “”
2A, accuracy: 1%, resolution: 0.025%;
PWM_2| J3-4
PWM_3| J3-5
PWM_4| J3-6
DO| D0_1| J2-5| When output, the corresponding do is about the supply voltage;
DC 1. 5A
D0_2| J2-14
Digital
input| DI_H/L| DI_H_l| J2-2| The low-level effective threshold voltage (0 –
4.5V), high level
the effective threshold voltage (5 – 36V)
---|---|---|---|---
DI_H_2| J2-3
DI_H_3| J2-4
DI_H_4| J2-7
DI_H_5| J2-12
DI_L_1| J2-8
DI_L_2| 1211
DI_L_3| 1216
Reset| Reset| J3-8| Arm reset, power on and
ground short circuit for 5S
(IND| GND| J2-1, J3-7| GND
+5V output| +5VOUT| J3-2| 5V±200mV power supply output,, Max output is300mA
DC Input| +12VIn| J3-11,12| Rating: 12V,
range: 9V-16V
---|---|---|---
communicate
on| CAN| CAN H| J2-6| There is no 120 inside Q Terminal resistance;
CAN_L| J2-15
Product parameters and environmental indicators
NO. | NAME | Detail |
---|---|---|
Kernel | STM32F4291G ( 32 bit ARM ) | |
Kernel frequency | 180MHz | |
Working cycle | ≤ 5 ms | |
CAN channel | 1. 15011898 CAN 2.08, 11939 | |
Voltage input | 9 ∼16V.DC ( Recommended voltage 12V.DC ) | |
Output | SV.DC. 300mA | |
Current | 0.12A.DC ( 12V.DC) ( NO LOAD ) | |
Power | ≤5W | |
9 | Working Temperature | -20 ∼ +65 r |
10 | Storage temperature | -25 ∼ +80 r |
1I | RS | 3V/m. 80MHz-661-1z |
I9 | ESD | Air discharge ±8kV |
Contact discharge ±4kV
I| Anti-vibration level| 6.8g
II| Shock resistance| 50g. 6ms
15| Relative humidity| ≤95%
16| Dimensions| 108X82X54 (mm)
17| Weight| 0.23Kg
NOTE
All the sensors, loads and other input and output points connected with the
display screen must be connected into a closed-loop, that is, all the input
and output ground must be connected with the corresponding ground of the
controller.
FCC Statement:
Any changes or modifications not expressly approved by the party responsible
for compliance could void the user’s authority to operate the equipment.
This device complies with part 15 of the FCC Rules. Operation is subject to
the following two conditions: (1) This device may not cause harmful
interference, and (2) this device must accept any interference received,
including interference that may cause undesired operation.
FCC Radiation Exposure Statement:
This equipment complies with FCC radiation exposure limits set forth for an
uncontrolled environment. This equipment should be installed and operated with
a minimum distance 20cm between the radiator& your body.
Note: This equipment has been tested and found to comply with the limits
for a Class B digital device, pursuant to part 15 of the FCC Rules. These
limits are designed to provide reasonable protection against harmful
interference in a residential installation. This equipment generates uses and
can radiate radio frequency energy and, if not installed and used in
accordance with the instructions, may cause harmful interference to radio
communications. However, there is no guarantee that interference will not
occur in a particular installation. If this equipment does cause harmful
interference to radio or television reception, which can be determined by
turning the equipment off and on, the user is encouraged to try to correct the
interference by one or more of the following measures:
—Reorient or relocate the receiving antenna.
—Increase the separation between the equipment and receiver.
—Connect the equipment into an outlet on a circuit different from that to
which the receiver is connected.
—Consult the dealer or an experienced radio/TV technician for help.
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>