Hobson Property Trust Trustee For John Webber Investment Trust T LiT YARD Outdoor Lighting System Owner’s Manual
Table of Contents
- Hobson Property Trust Trustee For John Webber Investment Trust T LiT YARD
- WHAT’S INCLUDED
- MOUNTING THE CONTROLLER
- MOUNTING THE RF BRIDGE
- QUICK SETUP PROCESS
- LIT YARD 2 QUICK SETUP
- LiT YARD RF BRIDGE LED STATUS
- HANDSET PAIRING
- REMOTE HANDSET OPERATION
- TROUBLESHOOTING – REMOTE HANDSET
- FCC COMPLIANCE STATEMENT
- SPECIFICATIONS
- TECHNICAL SPECIFICATION
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
Hobson Property Trust Trustee For John Webber Investment Trust T LiT YARD
Outdoor Lighting System
READ THIS FIRST
Read and follow the safety instructions listed below and other basic safety
precautions before installation or operation of this transformer and other
associated equipment. This power unit is specifically designed to supply 12
VAC to landsca pe, fountains, swimming pool,s and spa luminaires. Installation
must comply with provisions of the National Electrical Code, ANSI/NFPA 70,
including those in Article 680 – Swimming Pools, Spas, Fountains and Water
Features.
CAUTION: for use only on a branch circuit protected by a class a type
ground fault circuit interrupter.
Power supplies are for outdoor use only. Not for use with an extension cord.
WARNING
If the installation requires running wire through building structure,
special wiring methods are needed.
Do not submerge.
Do Not exceed the maximum ratings of individual components, wiring devices and
current carrying capacity of conductors.
PRODUCT SUPPORT & INFORMATION
VISIT: WWW.SPAELECTRICS.COM
WHAT’S INCLUDED
MOUNTING THE CONTROLLER
POSITIONING
ENSURE THE LiT YARD 2 OUTDOOR LIGHTING CONTROLLER IS WALL MOUNTED AT LEAST 20″
[500mm] ABOVE GROUND AND IN A SERVICEABLE LOCATION.
NOTE
This product has been designed for use with PVC/Flexible conduit, it is not
intended to be used with metallic conduit. Connections/hubs need to be UL
Listed, weather/rain-t ight and suitable for the application. All conduits
should be adequately supported to prevent excessive stress on the enclosure.
MOUNTING THE RF BRIDGE
POSITIONING
WHEN FINDING A LOCATION TO MOUNT THE LiT YARD 2 RF BRIDGE, THERE ARE SOME
FACTORS THAT WILL IMPROVE THE CONNECTIVITY OF YOUR RF BRIDGE TO YOUR REMOTE
HANDSET.
THE RF BRIDGE SHOULD BE MOUNTED:
- IN AN ELEVATED POSITION.
- OUTSIDE OF ENCLOSURES. eg. PUMP HOUSES OR GARDEN SHEDS.
- MINIMIZING THE NUMBER OF OBSTRUCTIONS BETWEEN THE RF BRIDGE AND THE REMOTE HANDSET WILL IMPROVE THE CONNECTIVITY BETWEEN THE DEVICES. MATERIALS SUCH AS TIN, STEEL AND CONCRETE CAN HAVE A DETRIMENTAL AFFECT ON THE RF BRIDGE SIGNAL TO THE REMOTE HANDSET.
- THE REMOTE HANDSET SHOULD BE WITHIN A 54 ya rd ( 5 0 m I LI NE OF SIGHT OF THE RF BRIDGE.
-
INSTALLING THE KEYHOLE SCREW
THE RF BRIDGE USES A KEYHOLE HOOK ARRANGEMENT FOR MOUNTING. FASTEN THE SCREW INTO THE WALL MATERIAL UNTIL THE SCREW HAS 1/4-1 /2 inches (7-1 1 MM) STILL EXPOSED FROM THE WALL. -
ATTACHING RF BRIDGE TO KEY HOLE SCREW
-
REMOVE THE LOWER COVER ON THE RF BRIDGE TO EXPOSE THE LOWER MOUNTING HOLE.
-
FASTEN A SCREW THROUGH THE LOWER MOUNTING HOLE INTO THE WALL MATERIAL.
NOTE WHEN MOUNTING THE RF BRIDGE TO CONCRETE OR BRICK, IT IS ADVISED TO FIRST USE THE RF BRIDGE TO MARK THE MOUNTING HOLE POSITION AND REMOVE THE RF BRIDGE BEFORE DRILLING THE PILOT HOLE.
CABLE CONNECTIONS
CONNECTING THE RF BRIDGE
-
1. REMOVE THE COVER AND INSERT THE RJ12 CABLE INTO THE RF BRIDGE
-
INSERT THE RJ12 CABLE INTO THE CABLE GUIDE SLOT ON THE LOWER COVER OF THE RF BRIDGE.
-
RE-INSTALL THE LOWER COVER ON TO THE RF BRIDGE.
WIRING – EXAMPLE 1
NOTE
POOL & SPA CHANNELS CAN BE CONTROLLED INDEPENDENTLY OR AS A GROUP VIA THE
REMOTE.
WIRING – EXAMPLE 2
NOTE
POOL & SPA CHANNELS CAN BE CONTROLLED INDEPENDENTLY OR AS A GROUP VIA THE
REMOTE.
WIRING – EXAMPLE 3
LARGER INSTALLATION?
THE LiT YARD SYSTEM CAN SUPPORT A MAXIMUM OF 10 CONTROLLERS. EACH LiT YARD 2 CONTROLLER REQUIRES ITS OWN RF BRIDGE.
QUICK SETUP PROCESS
BEFORE YOU START
- The Remote Handset is designed to be used with the Spa Elect r ics LiT YARD 2 Controller. [Please check product labeling to ensure it is su itable]
- For Retro-fit installat ions, where existing transformers have been hardwired; a suitably qualified elect rician must disconnect the transformers and terminate with a plug top connection in accordance with NEC and State Electrical Codes for hardwired installations.
LIT YARD 2 QUICK SETUP
The Remote Handset has a QUICK SETUP feature to program LiT YARD 2 for operation.
-
STEP 1
Ensure the lights have been OFF for a minimum of 30 seconds, then turn the system ON using the Remote Handset. -
STEP 2
Press the following static colors in order with a 1-second pause between each press.- WHITE
- RED
- GREEN
If performed correctly, the lights will illuminate GREEN. Confirm the correct operation by selecting a different color using the Remote Handset.
LiT YARD RF BRIDGE LED STATUS
THE FRONT OF THE LIT YARD RF BRIDGE HAS AN LED INDICATOR. PLEASE SEE BELOW FOR THE STATUS OF THE DIFFERENT COLORS INDICATED.
HANDSET PAIRING
Your Remote Handset should come pre-assigned to the LiT YARD RF Bridge
However, if it is not paired, please follow the below instructions:
STEP 1: Press the pairing button on the base of the LiT YARD RF Bridge.
The LiT YARD RF Bridge will now switch to learning mode, indicated by the
flashing red LED.
STEP 2: Within 1 second, press any of the buttons on the Remote Handset.
The Remote Handset is now assigned to the LiT YARD RF Bridge
MEMORY RESET: To reset the receiver memory, press and hold the button on
the bottom of the LiT YARD RF Bridge for 10 seconds. The LED indicator will
flash fast initially, then flash slow indicating the memory has been erased.
Once erased, re-lease the Button and complete steps 1 & 2 to program the
Remote Handset.
TO ACCESS THE PAIRING BUTTON ON THE LIT YARD RF BRIDGE
- Slide down the Bottom cover of the LiT YARD RF Bridge.
- The button is located to the left of the cable inputs.
REMOTE HANDSET OPERATION
TROUBLESHOOTING – REMOTE HANDSET
FCC COMPLIANCE STATEMENT
Warning: Changes or modifications not expressly approved by the party
responsible for compliance could
void the user’s authority to operate the equipment. This device complies with
part 15 of the FCC rules.
Operation is subject to the following two [2] conditions:
[1] This device may not cause harmful interference, and
[2] This device must accept any interference received, including interference
that may cause undesired operation.
Note: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
- Reorient or relocate the receiving antenna.
- Increase the separation between the equipment and receiver.
- Connect the equipment into an outlet on a circuit different to that to which the receiver is connected.
- Consult the dealer or an experienced radio/ TV technician for help.
The device radiates radio frequency energy at a level below the United States FCC radio frequency exposure limits. Nevertheless, this device should be used in such a manner that the potential for human contact during normal operation is minimized. For body-worn operation, this device has been tested and meets FCC RF exposure guidelines when used with an accessory that contains no metal. The use of other accessories may not ensure compliance with FCC RF exposure guidelines.
SPECIFICATIONS
- Enclosure Size: H27cm x W15cm x 010cm
- Enclosure Type: UL Listed Polycarbonate [black]
- Primary Conduit Entry: [2] ½” -¾” ports, [2] ¾” ports
- Secondary Conduit Entry: [2] ½” -¾” ports, [2] ¾” ports
- Overload Protection: Replaceable 1 OA blade fuse.
TECHNICAL SPECIFICATION
RECEIVER RATING
- Input: 110VAC ~ 60Hz
- Output: 11 0VAC ~ 60Hz switched
- Max. Load: 1 00W MAX. TOTAL
REMOTE
- Battery: 2 x ‘AAA’
- Range: Up to 50m – line of sight
- Freq: 916MHz ISM Band