BITMAIN Antminer S19a Server Bitcoin Miner Installation Guide
- June 6, 2024
- BITMAIN
Table of Contents
BITMAIN Antminer S19a Server Bitcoin Miner Installation Guide
Overview
The S19a server is Bitmain’s newest version in the 19 server series. Power supply APW12 Series is part of S19a server. All S19a servers are tested and configured prior to shipping to ensure easy set up.
Front View
Back View
Caution
- Please refer to the layout above to place your goods in usage in case of any damage.
- The equipment must be connected to an earthed mains socket-outlet. The socket-outlet shall be installed near the equipment and shall be easily accessible.
- The equipment has two power inputs, only by connecting those two power supply sockets simultaneously can the equipment run. When the equipment is powered off, be sure to power off all power inputs.
- DO NOT remove any screws and cables tied on the product.
- DO NOT PRESS the metal button on the cover.
S19a Server Components
The main components and controller front panel of S19a servers are shown in the following figure:
PW12 Series Power Supply:
Note
- Power supply APW12 Series is part of S19a server. For detailed parameters, please refer to the specifications below.
- Additional two power cords are needed
Specifications
Ve r sion: S19a 96T
Model No.: 240-Ce
Product Glance | Value |
---|---|
Version | S19a |
Crypto Algorithm/Coins | SHA256/BTC/BCH |
Hashrate, TH/s | 96 |
power on wall@25℃, Watt | 3312 |
power efficiency on wall @ 25°C , J/TH | 34.5 |
Server Size (LengthWidthHeight, with package), mm | 400195.5290 mm |
Net weight, kg | 13.2 |
Setting up the Server
To set up the server:
The file IPReporter.zip is supported by Microsoft Windows only.
-
Go to the following site:
https://shop.bitmain.com/support.htmpid=00720160906053730999PVD2K0vz0693 -
Download the following file: IPReporter.zip.
-
Extract the file.
The default DHCP network protocol distributes IP addresses automatically. -
Right-click IPReporter.exe and run it as Administrator.
-
Select one of the following options:
- Shelf, Step, Position – suitable for farm servers to mark the location of the servers.
- Default – suitable for home servers.
-
Click Start.
-
In your web browser, enter the IP address provided.
-
Proceed to login using root for both the username and password.
-
In the Protocol section, you can assign a Static IP address (optional).
-
Enter the IP address, Subnet mask, gateway and DNS Server.
-
Click “Save”.
-
Click https://support.bitmain.com/hc/en-us/articles/360018950053 to learn more about gateway and DNS Server.
Configuring the Server
Setting up the Pool
To configure the server:
-
Click Settings marked below.
Note: -
Fan speed percentage can be adjusted, but we recommend to keep the default setting. The server will adjust the fan speed automatically if the fan speed percentage has yet been selected;
-
There are two working modes of S19 server: Normal mode and Sleep mode. The server enters the sleep mode under the condition that the control board is powered while hashboards are not powered.
-
Set the options according to the following table:
Option| Description
---|---
Mining address| Enter the address of your desired pool.
The S19a servers can be set up with three mining pools, with decreasing priority from the first pool (pool 1) to the third pool (pool 3). The pools with low priority will only be used if all higher priority pools are offline.
Name| Your worker ID on the selected pool.
Password (optional)| The password for your selected worker. -
Click Save after the configuration.
Monitoring Your server
To check the operating status of your server:
-
Click dashboard marked below to check the server status (taking S19a 96T as an example).
Note: The S19a server (96T) is with fixed frequency 720 MHz. Firmware will stop running when the Temp (Outlet) reaches to 81℃,there will be an error message “over max temp, pcb temp (real-time temp)” shown on the bottom of kernel log page. Meanwhile, the server temperature on the dashboard interface turns to abnormal and shows “Temp is too high” -
Monitor your server according to the descriptions in the following table:
Option| Description
---|---
Number of chips| Number of chips detected in the chain.
Frequency| ASIC frequency setting.
Real Hashrate| Real-time Hashrate of each hash board (GH/s).
Inlet Temp| Temperature of the inlet (°C).
Outlet Temp| Temperature of the outlet (°C).
Chip state| One of the following statuses will appear:- The Green Icon – indicates normal
- The Red Icon – indicates abnormal
Administering Your Server
Checking Your Firmware Version
To check your firmware version:
- Enter the backstage of your server, find the firmware version on the bottom.
- Firmware Version displays the date of the firmware your server uses. In the examples below, the server is using firmware version 20210615.
Upgrading Your System
Make sure that the S19a server remains powered during the upgrade process. If power fails before the upgrade is completed, you will need to return it to Bitmain for repair.
To upgrade the server’s firmware:
-
In System, click Firmware Upgrade.
-
For Keep Settings:
- Select “keep settings” to keep your current settings (default).
- Unselect “keep settings” to reset the server to default settings.
-
When the upgrade is completed, restart the server and it will turn to the setting page
Modifying Your Password
To change your login password:
- In System, click the Password tab.
- Set your new password, then click Save.
Restoring Initial Settings
To restore your initial settings
- Turn on the server and let it run for 5 minutes.
- On the controller front panel, press and hold the Reset button for 10 seconds.
Resetting your server will reboot it and restore its default settings. The red LED will automatically flash once every 15 seconds if the reset is operated successfully.
Environmental Requirements
Please run your server in accordance with the following requirements
Basic Environmental Requirements:
Climatic Conditions
Description | Requirement |
---|---|
Operating Temperature | 0-40℃ |
Operating Humidity | 10-90%RH (non-condensing) |
Storage Temperature | -20-70℃ |
Storage Humidity | 5-95%RH(non-condensing) |
Altitude | <2000m |
Site Requirements of the Server Running Room:
Please keep the server running room away from industrial pollution sources:
For heavy pollution sources such as smelters and coal mines, the distance
should be more than 5km.
For moderate pollution sources such as chemical industries, rubber and
electroplating industries, the distance should be more than 3.7km.
For light pollution sources such as food factories and leather processing
factories, the distance should be more than 2km.
If unavoidable, the site should be chosen in the perennial upwind direction of
the pollution source.
Please do not set your location within 3.7km from the seaside or the salt
lake. If unavoidable, it should be built as airtight as possible, equipped
with air conditioning for cooling.
Electromagnetic Environmental Conditions:
Please keep your site away from transformers, high-voltage cables,
transmission lines and high-current equipment, for example, there should be no
high-power AC transformers (>10KA) within 20 meters, and no high-voltage power
lines within 50 meters.
Please keep your site away from high-power radio transmitters, for example,
there should be no high-power radio transmitters (>1500W) within 100 meters
Other Environmental Requirements:
The server running room shall be free of explosive, conductive, magnetically conductive and corrosive dust. The requirements of mechanical active substances are shown below:
Requirements of Mechanical Active Substances
Mechanical Active Substance | Requirement |
---|---|
Sand | <= 30mg/m3 |
Dust (suspended) | <= 0.2mg/m3 |
Dust (deposited) | <=1.5mg/m2h |
Requirements of Corrosive Gas
Corrosive Gas | Unit | Concentration |
---|---|---|
H2S | ppb | < 3 |
SO2 | ppb | < 10 |
Cl2 | ppb | < 1 |
NO2 | ppb | < 50 |
HF | ppb | < 1 |
NH3 | ppb | < 500 |
O3 | ppb | < 2 |
Note: ppb (part per billion) refers to the unit of concentration,1ppb stands for the volume ratio of part per billion.
Regulations
FCC Notice (FOR FCC CERTIFIED MODELS):
This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
Note
This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense.
EU WEEE: Disposal of Waste Equipment by Users in Private Household in the European Union
This symbol on the product or on its packaging indicates that this product must not be disposed of with your other household waste. Instead, it is your responsibility to dispose of your waste equipment by handling it over to a designated collection point for the recycling of waste electrical and electronic equipment. The separate collection and recycling of your waste equipment at the time of disposal will help to conserve natural resources and ensure that it is recycled in a manner that protects human health and the environment. For more information about where you can drop off your waste equipment for recycling, please contact your local city office, your household waste disposal service or the shop where your purchased the product.
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>