BRINK 614687-F Evap Controller Instruction Manual

June 6, 2024
BRINK

BRINK 614687-F Evap Controller

brink-air-control-module-white

This product may be used by children aged 8 years and over, persons with reduced mental capacity, physical limitations or lack or experience and knowledge if they are supervised or have been instructed in the use the product safely and are aware of the possible hazards. Children should not play with the product.
Cleaning and maintenance by the user may not be carried out by children without supervision.

All rights reserved.
The information applies for the standard product design. Brink Climate systems BV cannot therefore be held liable for any damage arising from product specifications deviating from the standard design. The available information has been compiled with every possible care, but Brink Climate systems BV cannot be held liable for any errors in the information or for the consequences of this. Brink Climate systems BV cannot be held liable for damage arising from work carried out by third parties.
Subject to modifications

Operation

The Evap controller controls the Evap system module based on the relative humidity (RH) and temperature measured in the room, therefore the controller must present in the room where you want the RH to be controlled.
The following are shown on the display of the Evap controller:

  • Functions
    Humidify (HUMIDIFY). Cool (Cool) or both (AUT) is not applicable for the Brink Evap

  • Status
    batteries, RF connection and control.

BRINK 614687-F Evap Controller fig1

Operation

The Evap controller communicates with the Evap system module via a wireless RF signal (868MHz). Based on the (pre-)set values (setpoints) the controller sends a signal to the Evap that responds to this. The (pre-)set values (setpoints) can be adjusted by the user.
N.B.! The display switches off automatically after 8 seconds to optimise the battery life. The controller connects 3 times per hour to the Evap system module to update the measured values and to adjust the humidification control to this.

Connect the Evap

To connect the Evap controller to the Evap system module the following steps must be followed::

  • Evap controller
1. Remove the back of the Evap controller by unscrewing the small screw on the bottom and carefully removing the back from the front.
2. You can now see the back of the PCB. There is a pushbutton on this, see blue arrow.![BRINK 614687-F Evap Controller fig2](https://manuals.plus/wp-content/uploads/2022/02/BRINK-614687-F-Evap-Controller-fig2.jpg) **Evap system module**
3. On the bottom of the Evap system module is a small opening level with the lock symbol on the sticker on the bottom.
4. Push in the button in this opening (using a paperclip) for 1 second.
5. The Power LED will flash (1 seconde on/1 second of).  

BRINK 614687-F Evap Controller fig3
Evap controller

6. Then push in the button on the back of the Evap controller (blue arrow). A green light will briefly flash.
7. Check that the connection between the controller and the system module has been made by pressing on ‘MODE’ button
8. In the top left of the display the RF symbol should now be visible.

Activate the controller display

  • Activate the Evap controller display:
    • Press mode
  • Seting the controller on RH (relative humidity)-mode:
    • Press after activating, with the arrow button to setting HUM101.
    • Press mode to confirm.
    • On the screen a faucet is visible, the Evap is now in the humidity-setting.
  • Change RH setpoint:
    • Activate the controller by pressing mode.
    • Ensure that the RH value is visible by pressing
    • Then press the arrow button to change the RH setpoint.
    • Press mode to confirm the new value.

Change temperature setpoint is not applicable for the Brink Evap

Controller menu

Technical menu

In the technical menu you can view the integrated temperature and relative humidity (RH) measurements. In this menu you can also reset the alarm and change the setpoint of the air flow sensor (SHC80). This menu can be accessed by holding down the mode button for 2 sec.

Main menu| Submenu| Description|
---|---|---|---
SETPNT| SP01| Setpoint temperature in the duct|
 | SP02| Setpoint RH duct|
TEMP| TS01| Measured duct temperature| Measured with the T1 sensor (SHC080)
 | TS02| Measured temperature after HRV| Measured with the T2 sensor
 | TS03| Measured outside temperature T3| If not connected, then standard 50°C
 | TS04| Setpoint temperature humidifier| Standard set on 12°C
 | TS05| Setpoint temperature indirect cooler| Not applicable for the Brink Evap
 | TS06| Setpoint temperature direct cooler| Not applicable for the Brink Evap
 | TS07| Minimal supply-air temperature| Not applicable for the Brink Evap
 | TS 08| Measured temperature return duct| Not applicable for the Brink Evap
HUM| RH01| Measured humidity in duct after Evap|
 | RH02| Measured humidity in return duct| Not applicable for the Brink Evap
COUNTR| CT01| Count valve humidifier|
 | CT02| Count valve cooler|
ALARM| AL01| Turn off service alarm|
 | AL02| Turn off alarm|
Menu navigation

1. Use the arrow buttons to change to the main menu
2. Press mode to select the menu
3. Use the arrow buttons to scroll between the submenus
4. Press mode to select a submenu
5. Use the arrow buttons to change the values
6. Press mode to confirm the change
7.   Press to go back one step

Example of changing setpoint RH and temperature duct

  • Press the mode button for 2 seconds.
  • Scroll with the arrow keys to SETPNT.
  • Press mode to select menu.
  • Scroll with the arrow keys to SP001 for temperature and SP002 for RH.
  • Press mode to select submenu SP001/SP002.
  • Use the arrow buttons to change the values
  • Press mode to confirm value.
  • Use to confirm value.

Display symbols

BRINK 614687-F Evap Controller fig6

Symbols general:

  • Wireless Communication: displays the signal strength.
  • Battery: remaining life of the batteries (4 x AAA).
  • Alarm: the text indicates signal. Look under Faults for explanation.
  • Demand: the level of operation, the higher the demand the more bars.

Symbols relevant for the Brink Evap:

  • Humidify: humidify function
  • Heat: heat function. This does not mean that this is actually on or that it is present

Faults and alarms

From serial number BR2018-H-00025

Alarm LED| Display

Tekst

| Meaning| Action| Reset
---|---|---|---|---
 | OFF| Measured outside temperature above set point

TS04

|  |
Alarm LED on| M OFF| Contact main enable broken, unit switches off| Restore contact main enable, see wiring diagram| Automatically
Alarm LED blinks

3 times

| SENSUP| Contact with SHC80 sensor broken| Check SHC80 wiring and if necessary repair, check that the light on SCH80 sensor flashes regularly, if not replace faulty

sensor.

| Automatically
Alarm LED blinks

5 times

| OUTDEF| T3 sensor outside air faulty| Check wiring for break or wear, in case of doubt replace sensor.| Automatically
Alarm LED blinks

9 times

| WATER| No rise of RH in duct| –  Check that the water tap is open.

If the valve is open and there is a demand (outside temperature below 12°C), check the screen in the connection coupling, which must be clean.

–  Check the operation of the water valve. Disconnect the black supply hose from the knee on the unit, and reset the unit by unplugging and re-inserting the unit; if water comes out and the water valve stops after 90 seconds, the valve is fine, the water continues to flow or no water comes out of the hose, the water valve is defective, replace the water valve. If the water valve works and the matrix does not get wet after the valve has been switched, the Legionella filter is clogged; replace the cassette.

If the matrix gets wet and still an alarm, then the matrix is dirty and the cassette needs to be replaced.

No.: 351025

| Automatically
Alarm LED blinks

15 times

| HEATER| Heating faulty| Check air temperature after the humidifier, this must be >8ºC, if not air heater is faulty. Call

installer for replacement.

| Automatically
Alarm LED blinks

17 times

| AIRFLW| No airflow| Check if HRV is working.| Automatically
Alarm LED blinks 19 times| T2DEF| T2 sensor outside air faulty| Check wiring for break or wear, in case of doubt replace sensor.| Automatically
---|---|---|---|---
Service LED continuously on| Service| The cassette must be replaced| To ensure safe humidification, it is necessary to replace the complete cassette; Order article 351025 from your dealer.


In the meantime, you can reset the service alarm by pressing the reset button for 30 seconds at the bottom. The opening is located next to the service LED.


ATTENTION the LegioSafe filter will soon be blocked and therefore a correct and safe operation is not

guaranteed !!

| You can reset the service alarm by pressing the reset button for 30 seconds at the bottom. The opening is located next to the service LED.



****BRINK 614687-F Evap Controller fig7

To serial number BR2018-H-00025

BRINK 614687-F Evap Controller fig8

EXAMPLE

The display shows: “WATER” and an “alarm” triangle.

Use of Humidifier: cause no water supply, or no increase in RH% measurement by SHC80. Actions: check that the tap is open, check that the valve is working by turning off power to the Evap system module and switching it on again. Listen to see whether water is flowing for min 20 seconds.

RESET procedure:

  • Activate LCD by pressing mode , wait 2 seconds, press mode again for 2 sec to go to the reset menu.
  • Display shows STPT.
  • Use the arrow buttons to scroll through the menu
  • If the display shows ALARM , press mode . Display indicates AL01 , press the arrow buttons until the display shows AL02. Press mode – the display shows NO
  • Press arrow buttons until display shows Rst.
  • Confirm reset by pressing mode and then the    button
  • Check reset by pressing mode
  • The ‘water’ and ‘alarm’ triangle should now have disappeared