User Manual Thank you for choosing Melodysusie! Please read this user guide carefully and keep it in an accessible location as you may refer to it later.
IMPORTANT SAFEGUARDS
READ ALL INSTRUCTIONS BEFORE USING.
To reduce the risk of burns, electrocution, fire, or injury to persons.
Please be sure to read the safety instruction as follow to avoid potential hazards that could result in personal injuries or damage to the device.
Check before Using
-
Check the power supply cord before the first use and during the life of the device. Do not use this device if it has a damaged cord or plug or it is not working properly or
damaged. -
Do not plug this device into a voltage system that is different from the voltage system specified on the device or charger.
Use with improper voltage will damage the device and VOID warranty. -
Please use the original charger only.
-
The handpiece of this device is not compatible with other models of nail drill machines from MelodySusie and other brands. Please don’t connect the handpiece with other nail drill machines
Note for Using
- Make sure your outlet supplies the correct power voltage to avoid damage to the lamp.
- Please do not unplug the power cord when the machine is working to avoid potential damage to the lamp.
- Do not place heavy objects on the lamp housing.
- Do not disassemble the device. Doing so could be dangerous and constitutes voiding warranty conditions.
- Do not draw out the connecting wires during use or touch the plug with the wet hand to prevent electric leakage and shock or fire. Please turn the power off after use.
- Do not use the crooked or damaged nail drill bit or replace the bit when the power is on.
- Adjust the speed gradually, not abruptly. Please stop using once the unusual movement and noise happen from the handpiece.
- Do not cover the ventilation of the handpiece avoiding burning your hand or touching any rotating part while the device is working.
- Misuse, dropping or excessive force may cause device damage.
- Please turn off the device and unplug the power cord before cleaning. Use a cloth with neutral detergent to clean the surface of the machine.
- Children under 18 years of age should not use this device without parental consent and supervision.
- If the device or the power cord is damaged, it should be repaired or replaced by MelodySusie or another authorized professional.
Maintenance Work
- Do not disassemble the device. Doing so could be dangerous and constitutes voiding warranty conditions.
- Do not keep the device in a place that is about or more than 50℃(in a metal box, car, or other places at high temperature). Keep the handpiece dry and keep it away from the oil and grease.
- Store the device in a cool and dry place. Do not store it in a hot or humid environment.
- Keep the electrical cord away from heated surfaces.
- Do not dispose of the device in heat or fire.
- Do not clean the device with harmful chemicals or detergents.
Note for Injury
- Having manicures done frequently can cause injuries to the nails as well.
- If you need to remove the gel polish of natural nails, try to use the nail polish remover pads to avoid damage to the nail bed with improper operation.
- Do not use the device if you have an open wound on your nail or hand.
- If you have any skin diseases, heat-sensitive, allergic reactions, onychomycosis, or any other disorder, you should consult your doctor and medical professional before using the device.
The operator shall be responsible for any consequences including product
damage or accidents if not strictly complies with the instructions. If you
require any technical support, contact us at
service@melodysusie.com
SAVE THESE INSTRUCTIONS
How to Use
Step 1 :Connect the handpiece to the handpiece jack.
Step 2 :Connect the power adapter with the DC socket.
Step 3: Choose the required time (15s/the 30s/60s/90s) to start working,
the default time is 15s.
Step 4: Choose a drill bit, release the handpiece, insert the drill bit
into the handpiece, and lock it in place.
Step 5 :Press the ON/OFF button to turn on the device
Step 6: Rotate the speed control knob to accelerate or decelerate the
rotation speed.
Step 7: Change the rotation direction of the grinding drill bit on the
F/R button if needed.
Step 8 : Press the ON/OFF button to turn off the device, unplug the power
adapter when you do not use it for a long time.
NOTE:
- Please turn off the power when you do not use the device.
- There has a protective film on the touch screen, please take it off to get a smooth and bright panel.
How to Replace Drill Bit
Please make sure that the desired bits are suitable for the collet.
Do not move the central barrel during operation.
Do not cover the ventilation holes on the handpiece, when using the device.
- Turn the central barrel clockwise until hearing a “click” sound to release the drill bit. Put the desired bit into the handpiece.
- Turn the central barrel counterclockwise until hearing a “click” sound to lock the drill bit in place.
- Be sure to confirm the rotation of the bit and collet. Please take care of your fingers not to be hurt by bit edge.
Problem and Terms of Settlement
Part 1 : Nail Lamp
Malfunctions
| Reasons|
Terms of settlement
The nail lamp does not work well. / The beads do not turn on.| The power
cord’s AC plug is loose or poorly connected.| Reconnect the power cord and
make sure it is properly connected or contact the MelodySusie customer service
team to change the power supply.
The nail lamp does not work well. / The beads do not turn on.|
The power cord’s AC output is not properly connected to the lamp’s AC
outlet.| Please make the power cord’s AC output is
properly connected to the lamp’s AC outlet.
Malfunctions | Reasons | Terms of settlement |
---|---|---|
The nail lamp does not work well. / The beads do not turn on. | The LCD screen | |
and the countdown are normal. But the LED light beads don’t turn on. | The LED |
light beads are defective or the lamp’s internal circuits are damaged. Please
contact our customer service team for help.
The LED light beads are defective or the lamp’s internal circuits are damaged.
Please contact our customer service team for help.| The light bead is damaged.
Please contact the MelodySusie customer service team to change the new light
beads.
The power cord’s AC plug is not compatible with the outlet.| Please kindly
note the plug is a US plug. If you want to use the nail lamp in other
countries or areas, please use it with a universal adaptor.
When pressing the button, the lamp doesn’t work.| Please check whether there
is water or dust on the button surface. Clean the nail lamp with a dry cloth.
The gel nail polish cannot be cured or dried| Insufficient curing time may
result in incomplete curing of your gel nail polish. The curing time
requirements vary from different gel polish brands and colors.| Please try to
extend the curing time appropriately until the nail surface is completely
cured. For best results, avoid moving your hand too much until curing is
complete.
The gel nail polish cannot be cured or dried| The light to your nail surface
is not enough.| Please adjust the angle of your nail surface until it faces
the light straight to ensure sufficient illumination.
Malfunctions| Reasons| Terms of settlement
---|---|---
The gel nail polish cannot be cured or dried| Please check whether the light
beads have been aged.| Please contactMelodySusie customer
service team to change the new light beads.
Use incompatible polish, such as regular nail polish, nail lacquer.| Please
use LED, UV gel nail polish, or a compatible nail lamp.
The gel polish is a bit tacky after drying.| Please wipe your nail surface
with a gentle cleanser or alcohol prep pads.
Part 2: Nail
Drill
Malfunctions| Causing| Terms of settlement
Changing the nail drill bit when the power is on| 1. motor burns out
2. Bearing damages (Loud Noise)
| Turn off the power when
changing the nail drill bit
The power is on when not in use| Turn off the power when not in use
Long time, Large load work| 1. Motor burns out
2. Device lifespan shortens
3. Bearing damages (Loud Noise)
4. Handpiece damages| The continuous working time should not be too long when
the working condition is in heavy load. When the device is overheating, it
should be stopped immediately to make it return to normal temperature.
Insert into a mismatched power supply| 1. Motor burns out| According to the
device voltage requirements, insert the matching power supply
Put the power cord at random/ Pull the power cord| 1. Device lifespan
shortens
2. Power cord brokes
3. Poor connection
4. Easy to cause a short circuit| Do not pull the power cord
Malfunctions| Causing| Terms of settlement
---|---|---
Replace the original charger randomly| 1. Device damages
2. Easy to cause a short circuit| Use the original specification charger
Dust into the handpiece| 1. Bearing damages (Loud Noise)
2. Handpiece damages| Clean dust, add the dust-proof protection of the
dustproof hood
The device drops to the ground or by other impacts| 1. Device damages
2. Handpiece damages| Avoid device drops or other impacts ( If the handpiece
was damaged, it can be purchased separately. )
Insert the nail drill bit into the handpiece incorrectly /Rotate the central
barrel into the place incorrectly /Take the drill bit out when the central
barrel is locked| 1. Drill bit falls out
2. High vibration
3. Drill bit stocks
4. The handpiece stocks and cannot be turned on 5. Handpiece damages| Insert
the nail drill bit into the device correctly/If the drill bit sticks, please
release the handpiece and try to take out it hard/Rotate the central barrel
correctly
Replace drill bit when the handpiece is not completely stopped| 1. The
handpiece stocks and cannot be turned on 2. Handpiece damages| Do not replace
the drill bit when the handpiece is not completely stopped
Cover the ventilation holes on the handpiece, when using the device| 1.
Handpiece overheats
2. Hand burns
Do not cover the| ventilation holes on the handpiece, when using the device
The size of the drill bit is not suitable| 1. Can not insert the drill bit
into the device| Use a standard drill bit
Water into the device/Operate in wet or moist conditions/Use a wet cloth to
clean the device| 1. Motor burns out
2. Device lifespan shortens| Do not operate in wet or moist conditions/Only a
dry cloth is allowed for cleaning
Specifications
Input voltage range: AC 100-240V/50-60Hz
Output Voltage: DC 24V/2A
Email: service@melodysusie.com
Website: http://www.melodysusie.com
Warranty and Customer Service
MelodySusie offers a 6-month limited warranty on quality-related issues. Please apply for your extra 6-month warranty extension and download the user manual in other languages by registering on www.melodysusie.com if needed.
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>