i Safe MOBILE M53A01 IS530.M1 Mining Smartphone Instructions
- June 6, 2024
- i safe MOBILE
Table of Contents
SAFETY INSTRUCTIONS
IS530.M1
EX MARKINGS
ATEX:
I M1 Ex ia I Ma IP64
II 2G Ex ib IIC T4 Gb
II 2D Ex ib IIIC T135°C Db IP6X
EU Type Examination Certificate:
EPS 19 ATEX 1 126 X
CE-designation: 2004
IECEx:
Ex ia I Ma IP64
Ex ib IIC T4 Gb
Ex ib IIIC T135°C Db IP6X
IECEx Certificate: IECEx EPS 19 .0062X
ANZEx:
Ex ia I Ma IP64
Ex ib IIC T4 Gb
Ex ib IIIC T135°C Db IP6X
ANZEx Certificate: ANZEx 20 .2002X
Temperature range:
-20°C … +60°C
Manufactured by:
i.safe MOBILE GmbH
i_Park Tauberfranken 10
97922 Lauda-Koenigshofen
Germany
EX-RELEVANT SAFETY REGULATIONS
Use of this device assumes that the operator observes the conventional
safety regulations and has read and understood the manual, safety
instructions, and certificate.
The following safety regulations must also be complied with:
-
Inside ex-hazardous areas, the covers of all interfaces must be closed.
To ensure the IP-protection, it has to be ensured that all gaskets are present and functional. There must be no large gap between the two halves of the housing. -
The device may only be charged outside ex-hazardous areas using the i.safe PROTECTOR 2.0 or i.safe PROTECTOR 3.0 USB-cable or other equipment approved by i.safe MOBILE GmbH.
-
The device may only be used in zones 1, 21, 2, 22, M1, or M2.
The device may only be charged at ambient temperatures between +5°C … +35°C. The device may not be exposed to any aggressive acids or alkalis.
The device shall be protected against the effects of oils, greases, and hydraulic fluids. -
The device must be protected from impacts with high impact energy, against excessive UV light emission and high electrostatic processes.
The ISM interface of the 15530.M1 can be used within hazardous areas with approved accessories. For ISM interface use, the i.safe MOBILE headset IS- HS1.1 and the trigger handle IS-TH1xx.M1 is approved. If the ISM interface is not used, it must be securely closed by the cover provided for this purpose.
The SD cards type IS-SD164.1 and IS-5D1128.1 may be used in the corresponding slot in the hazardous area. -
SIM cards that comply with the intrinsic safety entity parameters may be used in the corresponding slots in the hazardous area.
INFORMATION CONCERNING SAR CERTIFICATION (SPECIFIC ABSORBATION RATE)
Maximum SAR values for this model and the conditions under which these were
determined:
SAR (head) | 0 .81 W/kg |
---|---|
SAR (body – worn) | 1 .54 W/kg |
This device was tested for typical body-worn operations with the back of the handset kept 5 mm from the body. The device complies with RF specifications when the device is used at 5 mm from your body.
- The product shall only be connected to a USB interface of version USB2 .0.
- Adapter shall be installed near the equipment and shall be easily accessible.
Restrictions in the 5 GHz band:
According to Article 10 (10) of Directive 2014/53/EU, the packaging shows that
this radio equipment will be subject to some restrictions when placed on the
market in Kingdom
The WLAN function for this device is restricted to indoor use only when
operating in the 5150 to 5350 MHz frequency range.
| AT| BE| BG| CH| CY| CZ| DE
---|---|---|---|---|---|---|---
DK| EE| EL| ES| Fl| FR| HR
HU| IE| IS| IT| LI| LT| LU
LV| MT| NL| PL| PT| RO| SE
SI| SK| TR| UK| | |
EU DECLARATION OF CONFORMITY
EU – Declaration of Conformity according to directive 2014/34/EU,
2014/53/EU, and 2011/65/EU (2015/863/EU)
The company i.safe MOBILE GmbH declares under its sole responsibility that the
product to which this declaration relates is in accordance with the provisions
of the following data, directives, and standards:
Name & address of the manufacturer in the EU| i.safe MOBILE GmbH
i_Park Tauberfranken 10 97922 Lauda — Koenigshofen Germany
---|---
Description of the devices| Explosion protected smartphone
type / : IS530.M1 & 15-1151.1
model / : M53A01
Ex—marking| I M1 Ex is I Ma IP64
II 26 Ex ib IIC T4 Gb
II 2D Ex ib IOC T135°C Db IP6x
Type examination certificate 2014/34/EU issued by Applied harmonized
standards| EPS 19 ATEX 1 126 X
Bureau Veritas E&E Product Services GmbH Businesspark A96
86842 Tuerkheim, Germany
identification number / : 2004
EN IEC 60079-0:2018; EN60079-11:2012
Conformity statement 2014/53/EU issued by Applied harmonized standards|
PHOENIX TESTLAB GmbH
Koenigswinkel 10
32825 Blomberg
Germany
identification number / : 0700
EN 62368-1:2014+A11:2017;
EN 50332-1:2013; EN 50332-2:2013; EN 50360:2017; EN 50566:2017;
EN IEC 62311:2020; EN 62479:2010;
EN 50663:2017; EN 62209-1:2016;
| EN 62209-2:2010+A1:2019;
---|---
| ETSI EN 301 489-1 V2.2.3;
| ETSI EN 301 489-3 V2.1.1;
| ETSI EN 301 489-17 V3.2.4;
| ETSI EN 301 489-19 V2.1.1;
| Draft ETSI EN 301 489-52 V1.1.0;
| EN 55032:2015+A11:2020;
| EN 55035:2017+A11:2020;
| ETSI EN 301 511 V12.5.1;
| ETSI EN 301 908-1 V13.1.1;
| ETSI EN 301 908-2 V13.1.1;
| ETSI EN 300 328 V2.2.2;
| ETSI EN 301 893 V2.1.1;
| ETSI EN 300 440 V2.2.1;
| ETSI EN 300 330 V2.1.1;
| ETSI EN 303 413 V1.1.1
Conformity statement 2015/863/EU amending| SGS-CsTC Standards
Technical Services Co.,
2011/65/EU issued by| Ltd.
| 198 Kezhu Road,
Scientech Park Guangzhou Economic &
| Technology Development District, Guangzhou, China
510663
Applied harmonized standards| IEC 62321-2: 2013; IEC
62321-1:2013;
| IEC 62321-3-1: 2013; IEC 62321-5: 2013;
| IEC 62321-4: 2013 + Al: 2017;
| IEC 62321-7-1: 2015;
| IEC 62321-7-2: 2017 & ISO 17075-1: 2017;
| IEC 62321-6: 2015;
| IEC 62321-8: 2017
CE Marking|
****Lauda – Koenigshofen 06.12.2021
Dirk Amann
Managing Director
1029CC08REV01_cmu All rights reserved, i.safe MOBILE GmbH
References
- AT&T Official Site | Our Best Wireless & Internet Service
- Zertifizierte Smartphones, Tablets und Mobiltelefone für IECEx und ATEX Zonen
- Wir beraten Sie weltweit
- Ex-geschützte Kommunikationsgeräte ATEX/IECEx-zertifiziert
- Betriebsanleitungen, Produktflyer, Datenblätter uvm.
- Service & Support
- We advise you worldwide
- Ex devices for ATEX IECEx Zone 1/21
- Service and Support – i.safe MOBILE
- Datasheets, Manuals, Certificates and Product Folders
- Our service team will be happy to assist you
- I.SAFE MOBILE À L'ÉCHELLE MONDIALE
- Appareils ATEX i.safe MOBILE pour zones de protection antidéflagrante
- Service chez
- Support - Official i.safe MOBILE Support
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>