THE MONOCRYSTALLINE SOLAR PANEL
REDARC Monocrystalline Solar Panels are highly efficient with a robust design.
A tempered glass coating combined with an anodized aluminium frame ensure that
our panels will withstand harsh road conditions and extreme weather
conditions.
WARNING & SAFETY INSTRUCTIONS
SAVE THESE INSTRUCTIONS — THIS MANUAL CONTAINS IMPORTANT SAFETY INSTRUCTIONS
FOR REDARC MONOCRYSTALLINE SOLAR PANELS.
DO NOT operate Monocrystalline Solar Panels UNLESS YOU
HAVE READ AND UNDERSTOOD THIS MANUAL and the Panel is installed as per these
installation instructions. REDARC recommends that the Panel be installed by a
suitably qualified person.
WARNING
RISK OF EXPLOSIVE GASES:
Working in vicinity of a Lead-Acid battery is dangerous. Batteries generate
explosive gases during normal operation. For this reason, it is of utmost
importance that you follow the instructions when installing and using the
Solar Panel.
WARNING: Check the manufacturers data for your battery and ensure that the
‘Absorption’ voltage of the regulator you select does not exceed the
manufacturers recommended maximum charging voltage. If the ‘Absorption’
voltage for your battery type is too high, please select another charging
profile or regulator (regulator not included).
RISK OF DAMAGE AND INJURY FROM IMPROPERLY SECURED PANELS:
Solar panels mounted to all types of vehicles, including but not limited to,
4×4 Vehicles, RVs, Caravans, etc. are subject to high wind and vibration
forces when driving. The instructions provided in this manual are just
intended as a guide. Solar panels must be securely attached to the vehicle in
accordance with all local and national safety standards. In addition, the
solar mount manufactures’ instructions must be adhered to or may be required
to be exceeded to comply with local and national standards. It is recommended
that a suitably qualified installer be used.
CAUTION
-
This appliance is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities, or lack of experience and knowledge, unless they are supervised or have been instructed on how to use the appliance by a person responsible for their safety. Children should be supervised to ensure that they do not play with the appliance.
-
Do NOT connect the Solar Panel directly to a Battery. A Solar Regulator must be used between the Solar Panel and the Battery.
-
Only use the Solar Panel for charging Lead Acid, Gel, Calcium content, AGM or Lithium Iron Phosphate 12 V batteries using a Solar Regulator suitable for the Battery’s chemistry.
Check the manufacturer’s data for your battery and ensure that the ‘Maximum’ voltage of the profile you select does not exceed the manufacturer’s recommended maximum charging voltage. If the ‘Maximum’ voltage is too high for your battery type, please select another charging profile. -
The Battery should be mounted in a well ventilated area, as far as possible from any ignition sources. NEVER smoke or allow a spark or flame in the vicinity of battery or engine. This may cause the battery to explode.
-
An unconnected panel exposed to light may generate voltages greater than 20 V on their leads. Completely cover all panels with an opaque material during installation, and when connecting or disconnecting conductors to reduce the chance of an electrical spark.
-
The Solar Panel will achieve best results when proper battery maintenance is regularly performed. This includes but is not limited to checking water and specific gravity levels of the battery.
-
Do not use mirrors or other devices to artificially concentrate sunlight on the panel.
-
All panels used in series, parallel, or series-parallel should be positioned to receive identical amounts of light to reduce risk of panel damage.
-
Partially shaded or partially obscured solar panels will have reduced output, and can potentially damage the solar panel.
PERSONAL SAFETY PRECAUTIONS -
To assist with the safe operation and use of the Solar Panel when connected (via a Regulator) to the battery:
- Wear complete eye protection and clothing protection. Avoid touching eyes while working near a battery.
- If battery acid contacts your skin or clothing, remove the affected clothing and wash the affected area of your skin immediately with soap and water. If battery acid enters your eye, immediately flood the eye with running cold water for at least 10 minutes and seek medical assistance immediately.
PANEL FEATURES
50 WATT MONOCRYSTALLINE SOLAR PANEL
SPECIFICATIONS
Model| SMSP1050| ****
Operating temperature
| −40°C to +85°C /
−40°F to +185°F
---|---|---|---
Peak power| 50 W
Cell construction| Monocrystalline| Max power voltage| 20.0 V
Cable length| 900 mm / 3 ft| Max power current| 2.5 A
Frame| Anodized aluminium| Open circuit voltage| 22.3 V
Front material| Tempered glass| Short circuit current| 2.7 A
Dimensions| 590 × 505 × 35 mm /
23.2″ × 19.9″ × 1.4″
| Power to temperature coefficient| −0.41%/°C / −0.23%/°F
Net weight| 3.6 kg / 7.9 lb| Power tolerance| ±3%
Conversion efficiency| 20.6%| Standard test conditions| AM1.5 1000
W/m2 25°C / 77°F
80 WATT MONOCRYSTALLINE SOLAR PANEL
SPECIFICATIONS
Model| SMSP1080| ****
Operating temperature
| −40°C to +85°C /
−40°F to +185°F
---|---|---|---
Peak power| 80 W
Cell construction| Monocrystalline| Max power voltage| 20.0 V
Cable length| 900 mm / 3 ft| Max power current| 4.0 A
Frame| Anodized aluminium| Open circuit voltage| 22.3 V
Front material| Tempered glass| Short circuit current| 4.32 A
Dimensions| 700 × 670 × 35 mm /
27.6 × 26.4″ × 1.4″
| Power to temperature coefficient| −0.41%/°C / −0.23%/°F
Net weight| 5.5 kg / 12.0 lb| Power tolerance| ±3%
Conversion efficiency| 20.6%| Standard test conditions| AM1.5 1000
W/m2 25°C / 77°F
120 WATT MONOCRYSTALLINE SOLAR PANEL
SPECIFICATIONS
Model| SMSP1120| ****
Operating temperature
| −40°C to +85°C /
−40°F to +185°F
---|---|---|---
Peak power| 120 W
Cell construction| Monocrystalline| Max power voltage| 20.0 V
Cable length| 900 mm / 3 ft| Max power current| 6.0 A
Frame| Anodized aluminium| Open circuit voltage| 22.3 V
Front material| Tempered glass| Short circuit current| 6.48 A
Dimensions| 1005 × 670 × 35 mm /
39.6″ × 26.4″ × 1.4″
| Power to temperature coefficient| −0.41%/°C / −0.23%/°F
Net weight| 7.5 kg / 16.5 lb| Power tolerance| ±3%
Conversion efficiency| 20.6%| Standard test conditions| AM1.5 1000
W/m2 25°C / 77°F
180 WATT MONOCRYSTALLINE SOLAR PANEL
SPECIFICATIONS
Model| SMSP1180| ****
Operating temperature
| −40°C to +85°C /
−40°F to +185°F
---|---|---|---
Peak power| 180 W
Cell construction| Monocrystalline| Max power voltage| 20.0 V
Cable length| 900 mm / 3 ft| Max power current| 9.0 A
Frame| Anodized aluminium| Open circuit voltage| 22.3 V
Front material| Tempered glass| Short circuit current| 9.72 A
Dimensions| 1475 × 670 × 35 mm /
58.1″ × 26.4″ × 1.4″
| Power to temperature coefficient| −0.41%/°C / −0.23%/°F
Net weight| 10.7 kg / 23.6 lb| Power tolerance| ±3%
Conversion efficiency| 20.6%| Standard test conditions| AM1.5 1000
W/m2 25°C / 77°F
200 WATT MONOCRYSTALLINE SOLAR PANEL
Model| SMSP1200| ****
Operating temperature
| −40°C to +85°C /
−40°F to +185°F
---|---|---|---
Peak power| 200 W
Cell construction| Monocrystalline| Max power voltage| 20.0 V
Cable length| 900 mm / 3 ft| Max power current| 10.0 A
Frame| Anodized aluminium| Open circuit voltage| 22.3 V
Front material| Tempered glass| Short circuit current| 10.8 A
Dimensions| 1110 × 992 × 35 mm /
43.7″ × 39.1″ × 1.4″
| Power to temperature coefficient| −0.41%/°C / −0.23%/°F
Net weight| 12.1 kg / 26.7 lb| Power tolerance| ±3%
Conversion efficiency| 20.6%| Standard test conditions| AM1.5 1000
W/m2 25°C / 77°F
SOLAR OPTIMISATION
ANGLE TO THE SUN
REDARC solar panels will perform at their peak with the panel face angled
directly towards the sun. However, in practice this is not always achievable.
REDARC recommends having your panels angled between 20° and 40° from the
ground. This will ensure the best total output from your panel across the
course of the day, no matter what season.
In the southern hemisphere, the sun is always in the NORTHERN half of the sky. As such facing your panel NORTH ensures the best angle to the sun for a solar panel across the course of the day. In the northern hemisphere, the sun is always in the SOUTHERN half of the sky. As such facing your panel SOUTH ensures the best angle to the sun for a solar panel across the course of the day.
SYSTEM INSTALLATION
ABS PLASTIC MOUNTS
ABS Plastic Corner, Side and Spoiler mounts are designed to mount single or
multiple panels to your RV or Caravan roof. The ABS plastic can be mounted
using silicon adhesive, specifically designed adhesive tape or screws. The
panels are then mounted to the ABS plastic mounts using standard metal screws.
ABS Plastic spoiler mounts are designed to keep the wind resistance and
resulting noise of your solar installation to a minimum.
WARNING
RISK OF DAMAGE AND INJURY FROM IMPROPERLY SECURED PANELS:
WARNING: Solar panels mounted to all types of vehicles, including but not
limited to, 4×4 Vehicles, RVs, Caravans, etc. are subject to high wind and
vibration forces when driving. The instructions provided in this section are
just intended as a guide. Solar panels must be securely attached to the
vehicle in accordance with all local and national safety standards. In
addition, the solar mount manufactures’ instructions must be adhered to or may
be required to be exceeded to comply with local and national standards. It is
recommended that a suitably qualified installer be used.
INSTALLATION DIAGRAM
SYSTEM INSTALLATION
ABS PLASTIC MOUNTS
CAUTION
Be aware of shading that can occur as a result of roof mounted accessories on
your caravan or motor home. Shading sections of your solar panels will
significantly reduce your solar panels performance.
Care must be taken to avoid the possibility of shading in the final
installation position. During the installation process, ensure that the panels
are covered with an opaque material to prevent potentially dangerous voltages
from inadvertently being generated.
SYSTEM WIRING
PARALLEL AND SERIES CONNECTIONS
Solar arrays can be connected in Parallel or Series as per the diagrams below,
or a combination of the two. Connecting two identical panels (of the same
wattage) in parallel will multiply the total output current by 2 and keep the
system voltage at the same level. Conversely, connecting two identical panels
(of the same wattage) in series will multiply the system voltage by 2 and keep
the output current at the same level. Parallel connections should be made
using ‘Y’ connectors available through REDARC Solar suppliers. Series
connections should be made by connecting the negative connector of one panel
to the positive of the next.
WIRING MULTIPLE IDENTICAL PANELS
STANDARD BMS INSTALLATION
TYPICAL MANAGER SETUP
- The size of this fuse relates to the total current draw of all the loads connected to the House Battery, and should be rated slightly higher than this. REDARC recommends the use of MIDI Style Fuses.
- Essential loads are loads which must be left on at all times, until the battery is flat. Non‑essential loads are those switched off when the battery reaches a particular low‑charge level,which can be set in the ‘Advanced Settings’ menu.
- Both CANBus connections can be used for either the Display or Battery Sensor.
- Ensure the RED terminal on the Battery Sensor is connected to the Battery Positive Terminal.
BMS INSTALLATION DIAGRAM
WIRING PRECAUTIONS
- Ensure that all connections are made using REDARC recommended connectors and cables or other suitably rated connectors and cables.
- Ensure that total system current does not exceed the maximum current rating for either the cables or any connectors that are subject to the total current of the system.
- Ensure that grounding and fusing is adequate for the system as per wiring diagrams on pages 12 and 14.
- Ensure that all MC4 connections are crimped with the correct MC4 crimping tool. Contact REDARC for more information on purchasing this tool.
- All cable entries into the vehicle must be suitably sealed, REDARC Single or Double Cable Glands are recommended.
- If your regulator has a dedicated solar input ground (negative) terminal ensure that the negative ground from your solar panels is connected here.
ACCESSORIES
-
SRC0001-CK – MC4 CONNECTOR KIT
Comes with 1 × Male MC4 connector and crimp and 1 × Female MC4 connector and crimp. -
SRC0006 – MC4 ‘Y’ ADAPTOR KIT
For connecting 2 positive and 2 negative MC4 connectors in parallel.
Reduces the 2 outputs to 1 output. -
SMC0001 – SINGLE CABLE GLAND
For routing a single cable into your Caravan or RV. Use a suitable adhesive to seal the gland to the Caravan or RV and route the cable through the cable entry.
REDARC SOLAR PRODUCT WARRANTY
Limited Warranty
For full warranty terms and conditions, visit the link below or refer to the
contact details applicable to your region.
https://redarc.com.au/warranty
https://redarcelectronics.com/warranty
North America
www.redarcelectronics.com
REDARC Corporation
c/o Shallco, Inc. 308 Component Dr. Smithfield, NC 27577 USA
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>