REDARC BCDC124D DC Battery Charger Instructions

June 6, 2024
REDARC

REDARC BCDC124D DC Battery Charger

WIRING DIAGRAM FOR DC-DC CHARGERS

REDARC-BCDC124D-DC-Battery-Charger-fig2

  • High current equipment such as compressor. Max 80-amp.
  • Fix a fuse here rated to the max output charge current of the charger. See charger user manual for details. Max 60 amps!
  • Match these cables from your DC-DC charger.
  • Solar panel or solar array directly here. Max voltage of your rated DC-charger solar inputmustnolbe exceeded.
  • Negative ground only is not sufficient.We recommend a dedicated negative ground cable directly from the battery.
  • A shunt is used with battery monitoring systems. Make sure it is connected correctly.
  • Connect lights, fridge, small compressor and all your equipment that draws a maximum of 25 amps (each). Make sure the polarity ( + – ) is correct.
  • Negative ground only is not sufficient. We recommend a dedicated negative ground cable directly from the battery.
  • Power output for equipment that uses more than 25 amps. Max 50-amps.
  • Power output for equipment that uses mo than 25 amp Also good fo such as regular and AC chargers.

WIRING AN INVERTER WITH A SHUNT

Inverters larger than 350W draw too much current (A) to be able to be wired through the DC-HUB. Therefore, wire the positive + cable directly from Aux- battery+ via a fuse, and then the negative – cable to the LOAD side of the shunt.

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals