TVMSDBWK-001
TVMSDBWK-002
WIRING KITS FOR TVMS
The TVMSDBWK range allows the RedVision Total Vehicle Management System (TVMS) distribution box to measure the water level in an RV/motor home clean water tank. If installing this kit for a gray or black water tank, refer to the TVMS1280 Instruction Manual for further information.
The TVMS can report five states: empty, one-quarter, one-half, three-quarters, and full. The TVMS can measure the level of up to six tanks. A separate TVMSDBWK-001 is required for each tank. For more information, refer to the RedVision Instruction Manual available on the REDARC website.
TVMSDBWK-001 includes all parts. TVMSDBWK-002 contains only the Wiring Loom.
TVMSDBWK‑001
Water Tank Sensor Kit
5 m (16’5″) Wiring Loom
|
Crimp Lugs
---|---
Screw-in Water Level
Sensor Probes
TVMSDBWK‑002
Water Tank Sensor Wiring Loom
5 m (16’5″) Wiring Loom
WIRING & INSTALLATION DIAGRAM
INSTALLATION
MEASURE AND MARK (TVMSDBWK-001 Only)
CAUTION
Any Sensors positioned close to corners of the tank must be at least ½” (12.5
mm) away from the curvature of the tank, i.e. The centre of the probe must
have a radius of at least at ½” (12.5 mm) of flat surface to mount on.
On the side of the tank, measure out the Sensor positions, starting with the top Sensor at the 80% mark, then 60%, 40%, and 20%. Position the bottom Sensor as close to the bottom of the tanks as possible — Note that this means that the spacing between the Sensors may not all be equal.
Note: the Sensors do not have to be mounted in-line.
The example shown (‘Front’ view) is acceptable.
Before drilling, check each marked location for good access and confirm face
is flat both outside and inside at least 1″ (25 mm) around each position.
DRILL (TVMSDBWK-001 Only)
Ensure tank is empty of liquid before drilling holes.
Using a sharp 3⁄8″ (or 9.5 mm) drill bit, drill each marked location at slow
speed. Ensure the cut is clean (de-burr inside and out) as any irregularities
will prevent a good seal.
Note: Using a drill bit greater than 3⁄8″ (or 9.5 mm) in diameter may prevent
the Sensors from sealing properly, resulting in leaking.
INSERT SENSORS (TVMSDBWK-001 Only)
-
For each Sensor, remove the top nut.
-
At each location, gently push the Sensor through the drilled hole until the rubber stopper is flush with the outer tank surface.
-
Tighten the nut to form a waterproof seal (the rubber is squeezed against the inner wall). Torque to 0.5 lbf-ft (0.7 Nm)
WIRING
Connect the supplied Wiring Loom to your TVMS system (as detailed in the product user manual), and run the cable to the tank.
Optionally, the cable length can be reduced if required. Terminate each wire
using the supplied Crimp Lugs. Crimps can be soldered after crimping for a
more reliable connection but is not required.
To reduce strain from vibration on the wires and to avoid acciental shorting, we recommend applying heatshrink (not supplied) to the crimped wires/lugs.
For each Sensor, slide on the crimped Lug and secure with the second nut.
Torque to 0.5 lbf-ft (0.7 Nm) while preventing the nut closest to the tank
from rotating.
Wire colours:
- 80% (top) — BLUE wire
- 60% — WHITE wire
- 40% — GREEN wire
- 20% — YELLOW wire
- Empty (bottom) — RED wire
SECURE THE LOOM
Secure the Wiring Loom to the TVMS mounting surface approximately 3″ (100 mm)
from the connector. Suitable options include a P-clip or cable tie fastened to
the mounting surface.
This is to reduce vibration on the connector to prevent damage to the
connector and unit.
CLEAN WATER LEVEL REPORTING
The approximate tank level is reported by the RedVision App (Smartphone app or TVMS Display).
Reported Level | RedVision Indicator | Range (approximate) |
---|---|---|
Full | 100 to 80% | |
3/4 | 80 to 60% | |
1/2 | 60 to 40% | |
1/4 | 40 to 20% | |
Empty | 20 to 0% |
LIMITED WARRANTY
For full warranty terms and conditions, visit the Warranty page of the REDARC
website.
Refer to the web address and contact details applicable to your region.
Australia, New Zealand & Europe
www.redarc.com.au
REDARC Electronics Pty Ltd
23 Brodie Road (North),
Lonsdale SA 5160
Australia
North America
www.redarcelectronics.com
REDARC Corporation
c/o Shallco, Inc.
308 Component Dr.
Smithfield, NC 27577
USA
Australia +61 8 8322 4848
New Zealand +64-9-222-1024
UK & Europe +44 (0)20 3930 8109
USA +1 704-247-5150
Canada +1 604-260-5512
Mexico +52 558-526-2898
Design and specifications are subject to change without notice. | Copyright © 2021 REDARC Electronics Pty Ltd. All rights reserved. | REDARC®, THE POWER OF REDARC® and REDVISION® are trademarks of Redarc Electronics Pty Ltd.
CONTACT US
redarc.com.au |
redarcelectronics.com
Australia 1300 REDARC (1300-733-272)
New Zealand +64 9 222 1024
UK/Europe +44 (0)20 3930 8109
USA +1
704-247-5150
Canada +1 604-260-5512
Mexico +52
558-526-2898
References
- REDARC : Automotive Electronics, DC Charging & Brake Control
- REDARC : Automotive Electronics, DC Charging & Brake Control
- REDARC : Automotive Electronics, DC Charging & Brake Control
- REDARC : Automotive Electronics, DC Charging & Brake Control
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>