PROSPORT GAUGE Laser Fuel Level Sensor Instruction Manual

June 9, 2024
PROSPORT GAUGE

PROSPORT GAUGE Laser Fuel Level Sensor

PROSPORT-GAUGE-Laser-Fuel-Level Sensor-product-image

Sender Wiring

  1. Connect a good ground to the stud on the sender labeled “GND”.
  2. Connect a switched +12V power to the stud on the sender labeled “+12V”.
  3. Connect the fuel gauge’s signal wire/stud to the stud on the sender labeled “Gauge”.

Sender / Gauge Calibration

Averaging Switch Settings

  • ON – ON: Minimum averaging with fastest response.
  • ON – OFF: Short averaging.
  • OFF – ON: Medium averaging.
  • OFF – OFF: Long / normal averaging with longest response.

The correct averaging setting depends on the fuel tank size and volume. Normally, using a long average setting will make readings smooth but may update slowly when fuel level changes. In reality, fuel level change is very slow, so the long / normal averaging setting is recommended.

Calibration Steps

You don’t have to calibrate all settings; each calibration setting can be set independently. For example, if you change to a new gauge, you only need to calibrate the gauge settings, the tank low and full settings are still good. You can also calibrate the gauge without the fuel tank and calibrate the fuel level without the gauge.

  1. Gauge Empty Position:

    • The LED should be solid blue. Press P2 or P3 to move the gauge pointer to empty. If the pointer is initially above full or below empty, you may need to keep holding P2 or P3 for up to 8 seconds before you see the pointer move.
    • You may want to position the pointer a little below empty to make sure you don’t accidentally run out of fuel.
    • When the pointer is positioned to empty, press and hold P1 for 3 seconds until the LED turns off. Then release the button. The LED will flash red 3 times to confirm the new setting is saved. If the LED doesn’t flash red 3 times, the new setting is NOT saved.
      Note: If you only momentarily press P1, the current setting won’t be saved, and you will skip to the next setting.
  2. Gauge ½ Position:

    • The LED should be solid green. Press P2 or P3 to move the gauge pointer to ½. If the pointer is initially above or full or below empty, you may need to keep holding P2 or P3 for up to 8 seconds before you see the pointer move.
    • When the pointer is positioned to 1/2, press and hold P1 for 3 seconds until the LED turns off. Then release the button. The LED will flash red 3 times to confirm the new setting is saved. If the LED doesn’t flash red 3 times, the new setting is NOT saved.
      Note: If you only momentarily press P1, the current setting won’t be saved, and you will skip to the next setting.
  3. Gauge Full Position:

    • The LED should be solid red. Press P2 or P3 to move the gauge pointer to full. If the pointer is initially above or full or below empty, you may need to keep holding P2 or P3 for up to 8 seconds before you see the pointer move.
    • When the pointer is positioned to full, press and hold P1 for 3 seconds until the LED turns off. Then release the button. The LED will flash red 3 times to confirm the new setting is saved. If the LED doesn’t flash red 3 times, the new setting is NOT saved.
      Note: If you only momentarily press P1, the current setting won’t be saved, and you will skip to the next setting.
      Tank Calibration
  4. Tank Empty Position:

    • This calibration is to set the tank empty (away from sender) level. The LED should be flashing green.
    • Set up a flat target and sensor parallel to each other on a table. Set the distance between them equal to the depth of your tank minus a small reserve distance (1/2” reserve is typical). The LED will flash faster the closer the target is to the sender.
    • Once the correct distance is set, wait at least 10 seconds to make sure the sender’s reading is stable.
    • Press and hold P1 for 3 seconds until the LED turns off. Then release the button. The LED will flash red 3 times to confirm the new setting is saved. If the LED doesn’t flash red 3 times, the new setting is NOT saved.
      Note: If you only momentarily press P1, the current setting won’t be saved, and you will skip to the next setting.
  5. Tank Full Position:

    • This calibration is to set the tank full (near sender) level. The LED should be flashing blue.
    • Set up a flat target and sensor parallel to each other on a table. Set the distance between them equal to the distance between the bottom of the sender and the full fuel level + ¼”. The LED will flash faster the closer the target is to the sender.
    • Once the correct distance is set, wait at least 10 seconds to make sure the sender’s reading is stable.
    • Press and hold P1 for 3 seconds until the LED turns off. Then release the button. The LED will flash red 3 times to confirm the new setting is saved. If the LED doesn’t flash red 3 times, the new setting is NOT saved.
      Note: If you only momentarily press P1, the current setting won’t be saved, and you will exit the calibration.

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals