Go Power GP-ISW-200 Pure Sine Wave Inverter User Guide

June 6, 2024
Go Power

Go Power Logo

Go Power GP-ISW-200 Pure Sine Wave Inverter

Quick Start Guide

Go Power GP-ISW-200 Pure Sine Wave Inverter Parts 01

Go Power GP-ISW-200 Pure Sine Wave Inverter Parts 02

  1. ON / OFF / Remote Main Switch
  2. LED Indicator
  3. AC Output
  4. Function Switch
  5. DC Input Terminal
  6. Green Terminal
  7. Remote Port (RJ-11)
  8. Chassis Ground

Installation and Wiring – Overview

The GP-ISW should be located as close to the batteries as possible but not within the same compartment. The length and size of the DC Cables will affect performance. Long DC wires tend to lose efficiency and reduce the overall performance of the Inverter/Charger.
For optimum Inverter performance the GP-ISW must be installed so the front and rear air vents are not blocked or obstructed in any way. Do not install the GP-ISW in an area with limited air flow. Allow as much space around the Inverter as possible, leaving at least 4 inches of airspace clearance around all ventilation areas.

Tools and Materials Needed
  • Flathead Screwdriver (for wire terminals)
  • Philips Screwdriver (for mounting screws)

Tools and Materials Needed

Mounting Orientations
  • HORIZONTAL WALL MOUNT, BASE DOWN
    HORIZONTAL WALL MOUNT, BASE DOWN

  • HORIZONTAL MOUNT, BASE UP
    HORIZONTAL MOUNT, BASE UP

  • HORIZONTAL MOUNT, BASE DOWN
    HORIZONTAL MOUNT, BASE DOWN

  • VERTICAL MOUNT, DO NOT MOUNT THE GP-ISW IN THIS CONFIGURATION
    VERTICAL MOUNT, DO NOT MOUNT

LED Indicators

LED Indicators

Input Voltage Level
LED Status DC 12V DC 24V
Red < 11.0V < 22.0V
Orange 11.0 ~ 11.5V 22.0 ~ 23.0V
Green 11.5 ~ 15.0V 23.0 ~ 30.0V
Orange 15.0 ~ 15.5V 30.0 ~ 31.0V
Red < 15.5V > 31.0V
Input Voltage Level
LED Status Status Recovery Point
Green Normal
Red Over Current Protection/ Over Load Protection (AC output short-circuit
and over load)
Red Blink Under Voltage Protection/ (Input DC voltage under spec) 12.5V @

DC12V System 25V @ DC24V System
Red Fast Blink| Over Voltage Protection (Input DC voltage over spec)| 14.5V @ DC12V System 29V @ DC24V System
Orange| Device startup process abnormal| –
Orange Fast Blink| Under Temperature Protection/ (Heat sink temp. under -20°C)| > 0°C
(Heat sink temperature)
Orange Slow Blink| Over Temperature Protection (Heat sink temp. over 80°C)| < 60°C
(Heat sink temperature)

Specifications

Note: Both 12V and 24V inverter specifications are listed below.

| GP-ISW200| GP-ISW400
Continuous Output Power| 200 W (VA)| 400 W (VA)
Maximum Surge Rating| 250 W (VA)| 800 W (VA)
Output Waveform| Pure Sine Wave
Output Voltage Range ± 3%| 100 – 120 VAC (Dip Switch Selectable)
Input Voltage| 12 V: 10 – 16 VDC
Efficiency| 12 V: 89%
24 V: 91%| 12 V:88%
24 V: 89%
No Load Current Draw / Powersave| 12 V: <0.5A
24 V: <0.4A| 12 V: <1A @ 12VDC
24 V: <0.5 @ 24VDC
Input Protection| Reverse Polarity (Fuse) / Under Voltage / Over Voltage
Output Protection| Short Circuit / Overload / Over Temperature
Low Battery Alarm ± 0.3 V
(± 0.5 V for 24 V inverters)| 12 V: 10 V
24 V: 21 V
Low Battery Shutdown ± 0.3 V
(± 0.5 V for 24 V inverters)| 12 V: 10 V
24 V: 20 V
Operating Temperature Range| -4°F – 140°F (-20°C – 60°C)
Storage Temperature Range| -22°F – 158°F (-30°C – 70°C)
Cooling| Temperature and Load Controller Cooling Fan
AC Output Connections| Dual GFCI Outlet
Dimensions (W x H x L)| 5.91 x 2.68 x 7.36 inch
(150 x 68 x 187 mm)| 5.91 x 2.68 x 7.36 inch
(150 x 68 x 187 mm)
Weight| 3.5 lbs (1.6 kg)| 3.5 lbs (1.6 kg)
Warranty| 2 Years
Inverter Install Kits| | GP-DC-KIT1
Remotes (Optional)| | GP-ISW-R / GP-SWR-A
Regulations and Safety| EMC / Certified FCC Class B| EMC / Certified FCC Class B / Certified UL 458

See user manual for complete instructions at gpelectric.com

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>