ETS 3158 High Power Biconical Antenna User Manual
- June 6, 2024
- ETS
Table of Contents
Model 3158
High Power Biconical Antenna
User Manual
Model 3158 shown with optional pedestal Model 113870 (sold separately)
ETS-Lindgren Inc. reserves the right to make changes to any products herein to improve functioning or design. Although the information in this document has been carefully reviewed and is believed to be reliable, ETS-Lindgren does not assume any liability arising out of the application or use of any product or circuit described herein; nor does it convey any license under its patent rights nor the rights of others. All trademarks are the property of their respective owners.
© Copyright 20002021 by ETS-Lindgren Inc. All Rights Reserved. No part of this document may be copied by any means without written permission from ETS- Lindgren Inc.
Trademarks used in this document: The ETS-Lindgren logo and FACT are trademarks of ETS-Lindgren Inc.
Revision Record MANUAL, MODEL 3158 HIGH POWER BICON | Part #399262, Rev. H
Revision | Description | Date |
---|---|---|
A | Initial Release | December, 2000 |
B | Updates / edits | March, 2002 |
C | Updated Assembly and Mounting | |
Instructions; Rebrand | February, 2009 | |
D | Updated data; updated photos | May, 2009 |
E | Updated pedestal information | March, 2016 |
F | Added weight to specifications | August, 2016 |
G | Corrected list of supplied items | June, 2021 |
H | Clarified items sold separately | October, 2021 |
Notes, Cautions, and Warnings
Note: Denotes helpful information intended to provide tips for better use
of the product.
Caution: Denotes a hazard. Failure to follow instructions could result
in minor personal injury and/or property damage. Included text gives proper
procedures.
Warning: Denotes a hazard. Failure to follow instructions could result
in SEVERE personal injury and/or property damage. Included text gives proper
procedures.
**** See the ETS-Lindgren Product Information Bulletin for safety, regulatory, and other product marking information.
Safety Information
Refer to Manual: When product is marked with this symbol, see the instruction manual for additional information. If the instruction manual has been misplaced, download it fromwww.ets-lindgren.com, or contact ETS-Lindgren Customer Service.
High Voltage: Indicates presence of hazardous voltage. Unsafe practice could result in severe personal injury or death.
Introduction
The ETS-Lindgren Model 3158 High Field Biconical Antenna is specifically
designed for Immunity testing.
This linearly-polarized transmit antenna is optimized to generate high levels
of electromagnetic fields in the range of 20 MHz to 120 MHz.
Model 3158 shown with optional pedestal Model 113870 (sold separately)
The ability of the Model 3158 to handle high power levels over a broadband
makes it excellent for use in Radiated Susceptibility testing.
The biconical elements are made from welded aluminum tubing. The 4-to-1 ratio
balun network is fabricated from G10 fiberglass and specially machined brass
and aluminum support and contact parts. The bifilar inductors of the balun are
wound in precision-machined cuts to provide high barrier insulation between
windings while simultaneously giving good coupling between bifilar windings.
During manufacturing each Model 3158 is individually calibrated using the
three antenna method of calibration. The results of the calibration are
tabulated and included with the antenna.
ETS-Lindgren Product Information Bulletin
See the ETS-Lindgren Product Information Bulletin included with your shipment
for the following:
- Safety, regulatory, and other product marking information
- Steps to receive your shipment
- Steps to return a component for service
- ETS-Lindgren calibration service
- ETS-Lindgren contact information
Maintenance
Before performing any maintenance, follow the safety information in the
ETS-Lindgren Product Information Bulletin included with your shipment.
Maintenance of the Model 3158 is limited to external components such as
cables or connectors.
If you have any questions concerning maintenance, contact ETS-Lindgren
Customer Service.
Annual Calibration
See the Product Information Bulletin included with your shipment for
information on ETS-Lindgren calibration services.
Maintenance of Fiber Optics
Fiber optic connectors and cables can be damaged from airborne particles,
humidity and moisture, oils from the human body, and debris from the
connectors they plug into. Always handle connectors and cables with care,
using the following guidelines.
Before performing any maintenance, disconnect the fiber optic cables from
the unit and turn off power.
When disconnecting fiber optic cables, apply dust caps to the ends to
maintain their integrity.
Before connecting fiber optic cables, clean the connector tips.
Before attaching connectors, clean them with moisture-free compressed
air.
Failure to perform these tasks may result in damage to the fiber optic
connectors or cables.
Service Procedures
For the steps to return a system or system component to ETS-Lindgren for
service, see the Product Information Bulletin included with your shipment.
Specifications
Electrical Specifications
Frequency Range: | 20 MHz to 120 MHz |
---|---|
VSWR Ratio: | • Typical—2:1 |
• Maximum—5:1
Maximum Input Power:| 5 kW
Input Impedance:| 50 Ω
Connector:| 7/16 DIN female
Physical Specifications – Antenna Only
Length: | 1.14 m (3.74 ft) |
---|---|
Width: | 3.00 m (9.84 ft) |
Height: | 1.14 m (3.74 ft) |
Weight: | 16.33 kg (36 lbs) |
Physical Specifications – Pedestal (sold separately)
Length: | 1.73 m (5.68 ft) |
---|---|
Width: | 1.52 m (5.00 ft) |
Height: | 2.51 m (8.23 ft) |
Tilt Range: | 0° to 45° |
Assembly and Mounting Instructions
Before connecting any components, follow the safety information in the ETS- Lindgren Product Information Bulletin included with your shipment.
Illustration features optional components (sold separately).
The Model 3158 High Power Biconical Antenna is shipped unassembled, and
includes these parts:
- Balun
- Biconical element (2)
- Belleville washer (2)
An optional pedestal, Model 113870, is sold separately
Due to the size of the antenna, you must mount the balun onto the pedestal
before you attach the elements.
-
Run your antenna cable through the polarization tube and attach it to the connector on the bottom of the balun.
Illustration features optional components (sold separately). -
Place the bottom of the balun in the mount plate. Insert two washers and two hex bolts on both sides of the mount plate to firmly secure the
balun in place.
Do not cross thread any connections or permanent damage could occur. -
Slide a belleville washer onto the threaded screw end of one of the biconical elements.
-
Line up the screw threads on the element with the receptacle hole on the balun and turn the element until it is firmly secured in the balun.
-
Repeat step 3 and step 4 for the remaining biconical element.
Damage to the pneumatic system may occur if the air supply exceeds the maximum 50 psi–70 psi.
-
Connect the air solenoid tube to the air solenoid located on the back of the pedestal. Connect the other end to your air supply.
The Model 2090 (or next generation ETS-Lindgren controller, if applicable) is a separate component required for operation. -
Connect the fiber optic polarization cable to the polarization unit located on the back of the pedestal. Connect the other end to the Model 2090 Multi-Device Controller.
Typical Data
All data was measured in an ETS-Lindgren FACT™ 3 chamber; field for a 5-kW input.
Data from MIL-STD-461F/RTCA DO-160 Setup (No Bench)
MIL-STD-461F/RTCA DO-160 SETUP (NO BENCH)
Shown with optional pedestal Model 113870 (sold separately).
Data from ISO 11451-2 Setup
ISO 11451-2 SETUP
Shown with optional pedestal Model 113870 (sold separately).
Data from ECE Regulation 10 Setup
Power input for 30V/m at 2 meters from the antenna and 1 meter over the
ground.
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>