FRICO Elztrip EZ100 Electric Radiant Heater Instruction Manual
- June 6, 2024
- FRICO
Table of Contents
Original instructions
Elztrip EZ100
600 – 1500 W
Get In Touch
Call: 0845 6880112
Email : info@adremit.co.uk
Our Address
Prevent, Adremit Limited, Unit 5a, Commercial Yard,
Settle, North Yorkshire, BD24 9RH
Elztrip EZ100
Ecodesign Regulation (EU) 2015/1188 concerning local space heaters does not
apply to all application areas.
The Regulation applies when an installation is intended to provide thermal
comfort for people on the premises. The Regulation does not apply to heating
installations of a more technical nature e.g. in engineering/utility rooms, in
production processes, frost protection, etc. The Regulation also does not
apply to installations in vehicles, offshore or outdoors.
Many of Frisco’s products can be used as both local space heaters (as defined
in (EU) 2015/1188) and for technical heating purposes. It is up to the
installer responsible for the installation to assess whether the Ecodesign
Regulation is applicable or not. Control solutions for installations not
covered by the Ecodesign Regulation are listed in a separate table.
| L[mm]|
A[mm]
---|---|---
EZ106N| 870| 655
EZ111N| 1470| 1252
EZ115N| 1950| 1731
|
EZ10[mm]
---|---
A| 50
B| 50
C| 50
D| 500
E| 1800
Technical specifications
Type
| Heat output
[W]| Voltage
[V]| Amperage
[A]| Max.surface
temperature[°C]| DimensionsLxHxW
[mm]|
Weight
[kg]
---|---|---|---|---|---|---
EZ106N| 600| 230V~| 2,6| 320| 870x50x150| 3,2
EZ111N| 1100| 230V~| 4,6| 320| 1470x50x150| 5,4
EZ115N| 15400| 230V~| 6,5| 320| 1950x50x150| 7, 0
Protection class: IP44
CE is compliant.
Type | HxWxD[mm] |
---|---|
TAP16R | 87x87x53 |
TEP44 | 87x87x55 |
RTX54 | 82x88x25 |
SKG30 | 115x85x40 |
PDK65 | 102x70x50 |
Controls for installations not covered by the Ecodesign regulation (EU)
2015/1188
Type | HxWxD[mm] |
---|---|
KRT1900 | 165x57x60 |
KRTV19 | 165x57x60 |
Wiring diagrams
Internal wiring diagram
C ontrol by thermostat
Control by a
thermostat – for installations not covered by the Ecodesign regulation (EU)
2015/1188
Installation and operating instructions
General Instructions
Read these instructions carefully before installation and use. Keep this
manual for future reference.
The product may only be used as set out in the assembly and operating
instructions. The guarantee is only valid if the product is used in the manner
intended and in accordance
with the instructions.
Application area
Elztrip EZ100 has a single heating panel and is designed for ceiling heights
between 2.5 and 4 meters. EZ100 is used in shops, schools, exhibition halls,
workshops and hospitals. Private homes and offices are also common areas of
use.
EZ100 is suitable both for total and supplementary heating, as well as for
protection against cold draughts from large glass surfaces. Protection class:
IP44.
Operation
The panels have an operating temperature of up to 320 °C and the heat is
radiated to cold surfaces. Heating with radiant heaters is very energy
effecient and a high comfort level is obtained. Max. The surrounding
temperature is +30 °C.
Mounting
Elztrip EZ100 is mounted on the ceiling, on armature rails or suspended from
the ceiling by means of rods or chains. EZ100 is intended for permanent
installation and should always be mounted horizontally.
In rooms frequently used, the heater should be mounted 1.5 to 2 meters above
head height, see Fig. 3. The distance between the panels should not be more
than the height
between panel and floor, i.e ”a” should be less than ”H”, see Fig.3. For
minimum mounting distance, see Fig.4. Ceiling fixtures and screws are found
inside the connection box.
Mounting on the ceiling
- Mount the ceiling fixtures on the ceiling.
- Open the folded mounting hinges on the top side of the heater and hang the heater on the ceiling fixtures. See Fig. 1. Make sure that the guide pegs are fitted into the holes, o ensure that the heater is fixed in a horizontal position. Fasten the screws.
Mounting on the wall (only horizontal) Brackets for wall mounting (EZMVK) are extra.
- Mount the bracket on the wall.
- Open the folded mounting hinges on the top side of the heater and hang the heater on the brackets. See Fig. 2. Make sure that the guide pegs are fitted into the holes, to ensure that the heater is fixed in a horizontal position. Fasten the screws.
Connection
The terminal box cover has self-tapping screws. The screw should only be
unthreaded 1,5 turns, after which the cover can be removed. NB While the screw
is self-tapping, the hread is vulnerable to damage if the screw is fully
removed and replaced several times. EZ100 is intended for 230V~ and permanent
installation. The heater(s) should only be wired by a competent electrician
and in accordance with existing national regulations. The appliance should be
preceded by a double pole switch with at least 3 mm breaking gap. There are
two holes with cable glands Ø 21mm on the top of the connection box.
Connection and serial connection of EZ100 is done with a maximum cable size of
4×2.5 mm 2 + earth.
Control
When using this product as a local space heater according to Eco-design
Regulation (EU) 2015/1188, it must be supplemented with one of the following
approved controls.
-
TAP16R, an electronic thermostat that includes:
– Electronic room temperature control plus week timer
– Room temperature control with open window detection -
TAP16R and SKG30, black bulb sensor that includes:
– Electronic room temperature control plus week timer
– Room temperature control with open window detection
– Black bulb sensor -
TAP16R and PDK65, presence detector that includes:
– Electronic room temperature control plus week timer
– Room temperature control with open window detection
– Room temperature control with presence detection
The product can be controlled in a different way, e.g. by an overall control system (BMS), but in that case the responsibility lies with the installer to ensure that the control system is programmed to make the installation meet the requirements of Ecodesign Regulation (EU) 2015/1188.
Start-up
When the unit is used for the first time or after a long period of disuse,
smoke or odour may result from dust or dirt that has collected on the element.
This is completely normal and disappears after a short time.
Maintenance
There might be a rattling noise the first time of use when the surface coating
of the panels is settling.
If the heater is used in rooms where there are aerosols, lacquer, solvents and
similar, this can cause a coating on the panels and discolor them. The output
is not affected.
In all electrical heating appliances, small clicks can occur due to movement
when the material expands and contracts with changes in temperature.
Residual current circuit breaker
When the installation is protected by means of a residual current circuit
breaker, which trips when the appliance is connected, this may be due to
moisture in the heating element. When an appliance containing a heater element
has not been used for a long period or stored in a damp environment, moisture
can enter the element. This should not be seen as a fault, but is simply
rectified by connecting the appliance to the main supply via a socket without
a safety cut-out, so that the moisture can be eliminated from the element. The
drying time can vary from a few hours to a few days. As a preventive measure,
the unit should occasionally be run for a short time when it is not being used
for extended periods of time.
Packaging
Packaging materials are chosen with consideration to the environment and are
therefore recyclable.
Handling of product at end of working life
This product may contain substances necessary for the functionality of the
product but potentially dangerous for the environment. The product should not
be disposed mixed with general household waste but delivered to a designated
collection point for environmental recycling. Please contact the local
authority for further details of your nearest designated collection point.
Recycling of used products saves earth’s resources and reduces global
footprint.
Safety
-
For all installations of electrically heated products should a residual current circuit breaker 300 mA for fire protection be used.
-
The unit must not be fully or partially covered with clothing, or similar materials, as overheating can result in a fire risk! (E)
-
This appliance can be used by children aged from 8 years and above and persons with reduced physical, sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning use of the appliance in a safe way and understand the hazards involved. Children shall not play with the appliance. Cleaning and user maintenance shall not be made by children without supervision.
-
Children of less than 3 years should be kept away unless continuously supervised.
-
Children aged from 3 years and less than 8 years shall only switch on/off the appliance provided that it has been placed or installed in its intended normal operating
position and they have been given supervision or instruction concerning use of the appliance in a safe way and understand the hazards involved. -
Children aged from 3 years and less than 8 years shall not plug in, regulate and clean the appliance or perform user maintenance.
CAUTION — Some parts of this product can become very hot and cause burns. Particular attention has to be given where children and vulnerable people are present.
Main office
Frico AB Tel: +46 31 336 86 00
Box 102
SE-433 22 Partille: mailbox@frico.se
Sweden : www.frico.se
For latest updated information and information about your local
contact:www.frico.se
Art.no 208956, 2018-09-19 HH