FRICO IR3000 Infrared Heater Instruction Manual
- October 30, 2023
- FRICO
Table of Contents
Original instructions
IR3000, IR4500, IR6000
IR3000 Infrared Heater
Ecodesign Regulation (EU) 2015/1188 concerning local space heaters does not
apply to all application areas.
The Regulation applies when an installation is intended to provide thermal
comfort for people in the premises. The Regulation does not apply to heating
installations of a more technical nature e.g. in engineering/utility rooms, in
production processes, frost protection, etc. The Regulation also does not
apply to installations in vehicles, offshore or outdoors. Many of Frisco’s
products can be used as both local space heaters (as defined in (EU)
2015/1188) and for technical heating purposes. It is up to the installer
responsible for the installation to assess whether the Ecodesign Regulation is
applicable or not. Control solutions for installations not covered by the
Ecodesign Regulation are listed in a separate table.
Type | L1 [mm] | L2 [mm] |
---|---|---|
IR3000 | 600 | 1125 |
IR4500 | 900 | 1500 |
IR6000 | 1200 | 1875 |
Minimum distances
[mm]
Ceiling| A| 400
Wall, long side of the unit| B| 400
Wall, short side of the unit| C| 400
Flammable material| D| 700
Floor| E| 2300
Type | HxWxD [mm] |
---|---|
IRG3000 | 869x362x40 |
IRG4500 | 1235x362x40 |
IRG6000 | 1615x362x40 |
Controls
Type | HxWxD [mm] |
---|---|
TAP16R | 87x87x53 |
TEP44 | 87x87x55 |
RB3 | 155x87x43 |
RB123 | 155x87x43 |
RTX54 | 82x88x25 |
SKG30 | 115x85x40 |
PDK65 | 102x70x50 |
Controls for installations not covered by the Ecodesign Regulation (EU) 2015/1188
Type | HxWxD [mm] |
---|---|
KRT1900 | 165x57x60 |
KRTV19 | 165x57x60 |
S123 | 72x64x46 |
Technical specifications
Type| Output steps [kW]| Voltage [V]| Amperage [A]|
Max. element temperature [°C]| Dimensions LxHxW [mm]| Weight
[kg]
---|---|---|---|---|---|---
IR3000| 1/2/2003| 400V3N~| 4,3| 700| 1125x83x358| 9
IR4500| 1.5/3/4.5| 400V3N~| 6,5| 700| 1500x83x358| 11.1
IR6000| 2/4/2006| 400V3N~*| 8,7| 700| 1875x83x358| 13.2
*) Can also be connected 400V3~, but then without output steps. With neutral, one element tube at a time can be connected.
Protection class: IP44.
CE compliant.
Wiring diagrams
Internal wiring diagram
Control by thermostat and relaybox
Control by thermostat, relaybox and black bulb sensor
Control by relaybox with 3 step output control and presence detector
Control by thermostat, contactor and switch – for installations not covered by the Ecodesign Regulation (EU) 2015/1188
Main office Frico AB Industrivägen 41
SE-433 61 Sävedalen Sweden
Tel: +46 31 336 86 00
mailbox@frico.se
www.frico.net
For latest updated information and information about your local contact:
www.frico.net
Artnr. 204566, 2022-10-10 ZD