Frico PNF20 Panther 30 kW Instruction Manual

June 2, 2024
FRICO

Frico PNF20 Panther 30 kW

Technical Specifications

  • Item Type number: 334031, 334032, 334033, 334035
  • Output steps [kW]: PNF20 – 0/10/20, PNF2023 – 0/10/20, PNF30 – 0/10/20/30, PNF3023 – 0/10/20/30
  • Airflow: 78 dB(A)
  • Sound power: 51/62 dB(A)
  • Motor: 150 W
  • Voltage: 400V3N~ (for some models), 230V3~
  • Amperage: 29.5 A, 50.2 A, 43.9 A, 75.3 A
  • Weight: 28 kg, 29 kg, 31 kg, 33 kg

Product Usage Instructions

Mounting the Unit

  1. Detach bracket from the unit.
  2. Mark and drill holes on the wall.
  3. Mount the bracket on the wall.
  4. Hang the unit on the bracket.
  5. Adjust the angle and fix it with the lower screws.
  6. Tighten all screws securely.

Connection
To connect the Panther FC 20-30, refer to the FC Frico Control system using the specified item numbers and types for proper installation.

Resetting the Overheat Protection
In case of overheat protection activation, follow the RU instructions provided in the manual to reset the system.

FAQ

  • How do I reset the overheat protection on Panther FC 20-30?
    To reset the overheat protection, follow the instructions provided in the manual under the RU section.

  • What are the recommended accessories for Panther FC 20-30?
    The recommended accessories include Item Number 10275 – Type PLR30 with dimensions HxWxD [mm] 415x445x60.

  • What control systems are compatible with Panther FC 20-30?
    The fan heater must be supplemented with a FC control system such as FCDF, FCSF, FCPF, FCBF, among others. Refer to the manual for detailed compatibility information.

Frico-PNF20-Panther-30-kW-\(1\)

Minimum mounting distance

Frico-PNF20-Panther-30-kW-\(2\)

Frico-PNF20-Panther-30-kW-\(4\)

Frico-PNF20-Panther-30-kW-\(5\)

Frico-PNF20-Panther-30-kW-\(6\)

Frico-PNF20-Panther-30-kW-\(7\)

Frico-PNF20-Panther-30-kW-\(17\)

Accessories

Frico-PNF20-Panther-30-kW-\(18\)

Control systems FC Frico control

The fan heater must be supplemented with a FC control system.

Frico-PNF20-Panther-30-kW-\(9\)

Item number Type Name Dimensions
74688 FCDF FC Direct 89x89x26 mm (FCCF)
74689 FCSF FC Smart 89x89x26 mm (FCCF)
74690 FCPF FC Pro 89x89x26 mm (FCCF)
74691 FCBF FC Building 89x89x26 mm (FCCF)

Accessories

Frico-PNF20-Panther-30-kW-\(10\)

Item number Type Dimensions
74694 FCRTX 39x39x23 mm
74695 FCOTX 39x39x23 mm
74699 FCLAP 89x89x26 mm
74718 FCBC05 5 m
74719 FCBC10 10 m
74720 FCBC25 25 m
74721 FCSC10 10 m
74722 FCSC25 25 m
74703 FCTXRF for FC Smart, FC Pro 89x89x26 mm

See separate manual for FC.

Technical specifications

Panther FC 20 – 30 (IP44)

Frico-PNF20-Panther-30-kW-\(19\)

  1. Sound power (LWA) measurements according to ISO 27327-2: 2014, Installation type E.
  2. Sound pressure (LpA). Conditions: Distance to the unit 3 metres. Directional factor: 2. Equivalent absorption area: 200 m². At lowest/highest airflow.
  3. ∆t = temperature rise of passing air at maximum heat output and lowest/highest airflow.
  4. Approved for 380V/3ph/60Hz. Product performance for 380V/3ph/60Hz will differ from stated data.

Ecodesign Regulation (EU) 2015/1188Ecodesign Regulation (EU) 2015/1188

Type PNF20 PNF2023 PNF30 PNF3023
Heat output
Nominal heat output [kW] 20 20 30 30
Minimum heat output [kW] 10 10 10 10
Maximum continous heat output [kW] 20 20 30 30
Auxiliary electricity consumption
At nominal heat output [kW] 0,004 0,004 0,004 0,004
At minimum heat output [kW] 0,004 0,004 0,004 0,004
In standby mode [kW] 0,0005 0,0005 0,0005 0,0005
Features
Fan assisted output Yes Yes Yes Yes
Electronic room temperature control plus week timer Yes Yes Yes Yes
Room temperature control, with open window detection Yes Yes Yes Yes
Distance control option Yes Yes Yes Yes
Adaptive start control Yes Yes Yes Yes

For translation of the English texts used, see the respective language pages.

Frico-PNF20-Panther-30-kW-\(13\)

Wiring diagrams for control system in the FC manual.

Frico-PNF20-Panther-30-kW-\(14\)

Wiring diagrams for control system in the FC manual.

Internal wiring diagram
Panther FC 20-30 kW 230V3~

Frico-PNF20-Panther-30-kW-\(15\)

Wiring diagrams for control system in the FC manual.

Installation and operating instructions

General Instructions
Read these instructions carefully prior to installation and use. Keep this manual for future reference. The product may only be used as set out in the assembly and operating instructions. The guarantee is only valid should the product be used in the manner intended and in accordance with the instructions.

Application
Panther FC 20–30 is a range of powerful and quiet fan heaters intended for heating and drying in industrial premises and other large buildings. They are equipped with EC motor ensuring step less airflow control.
Protection class: IP44.

Mounting

The Panther fan heater is mounted on the wall with the supplied bracket. The bracket allows the fan heater to be angled downwards and to the side (30° left or right). The product must be mounted in such a way as to allow future service and maintenance. For minimum distance, see diagrams on the introduction pages. The bracket is fixed to the unit during transportation to not damage the unit.

  1. Detach the bracket from the unit by removing the lower screws.
  2. Mark and drill the holes for the bracket’s keyhole slots on the wall.
  3. Mount the bracket on the wall in the desired position (straight, to the left or to the right). Use screws and plugs suitable for the wall.
  4. Loosen the upper screws of the unit approximately 10 mm and hang the unit on the bracket.
  5. Adjust the fan heater to the desired angle and fasten it with the lower screws on both sides of the unit.
  6. Tighten all screws.

See pictures in the introduction pages.
The power supply to the unit must be disconnected during all service, repair and maintenance work.

Electrical installation
The Panther fan heater is intended for permanent installation. The installation, which should be preceded by an isolator switch with a contact separation of at least 3 mm, should only be wired by a competent electrician and in accordance with the latest edition of IEE wiring regulations. The electrical connection is made on the back of the unit. Pierce the grommet with a screwdriver before entering the cable. Open the lid by removing its four screws to access the connection area. The wiring diagram can be found on the inside of the lid. Power supply should be connected to the assigned terminal block.
See wiring diagrams.

Control
Panther FC is prepared for FC control system, available in several packages for different requirements. The FC packages are ordered separately. The fan heater has an integrated PC board which is connected to the selected external control system FC. Communication and sensor cables are connected to the PC board via grommets on the back on the unit. Should more than one fan heater be controlled by a single FC, an additional communication cable FCBC per unit will be required. Settings are made on the FC control panel. See manual for FC. FC will activate the after-run: when the heat is switched off, the fan will continue to run for a short while to cool the elements.

Start-up
When the unit is used for the first time or after a long period of non-use, smoke or an odour may result from dust or dirt which has collected on the element. This is completely normal and disappears after a short time.

Overheating
The fan heater is equipped with an overheat protection. If it is deployed due to overheating, reset as follows:

  1. Disconnect the power supply with the isolator switch.
  2. Determine the cause of overheating and rectify the fault.
  3. Reset by opening the lid and pushing the red button on top of the overheat protection until a click sound is heard. See pictures in the introduction pages.
  4. Put the lid back on and reconnect the heater. NOTE! All work inside the unit’s connection area must be carried out by a qualified technician and with the power supply disconnected.

Maintenance
Since fan motors and other components are maintenance-free, no maintenance other than cleaning is necessary. The level of cleaning can vary depending on local conditions. Undertake cleaning at least twice a year. Inlet and exhaust grilles, impeller and elements can be vacuum cleaned or wiped using a damp cloth. Use a brush when vacuuming to prevent damaging sensitive parts. Avoid the use of strong alkaline or acidic cleaning agents.

Residual current circuit breaker
When the installation is protected by means of a residual current circuit breaker, which trips when the appliance is connected, this may be due to moisture in the heating element. When an appliance containing a heater element has not been used for a long period or stored in a damp environment, moisture can enter the element. This should not be seen as a fault, but is simply rectified by connecting the appliance to the main supply via a socket without a safety cut-out so that the moisture can be eliminated from the element. The drying time can vary from a few hours to a few days. As a preventive measure, the unit should occasionally be run for a short time when it is not being used for extended periods of time.

Packaging
Packaging materials are chosen with consideration to the environment and are therefore recyclable.

Handling of product at end of working life
This product may contain substances necessary for the functionality of the product but potentially dangerous for the environment. The product should not be disposed of mixed with general household waste but delivered to a designated collection point for environmental recycling. Please contact the local authority for further details of your nearest designated collection point.

Safety

  • For all installations of electrically heated products a residual current circuit breaker 300 mA for fire protection should be used.
  • Keep the areas around the air intake and exhaust grilles free from possible obstructions!
  • The unit must not be fully or partially covered as overheating can result in a fire risk!
  • The unit must not be placed directly under fixed wall sockets!
  • This appliance can be used by children aged from 8 years and above and persons with reduced physical, sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning use of the appliance in a safe way and understand the hazards involved. Children shall not play with the appliance. Cleaning and user maintenance shall not be made by children without supervision.
  • Children of less than 3 years should be kept away unless continuously supervised.
  • Children aged from 3 years and less than 8 years shall only switch on/off the appliance provided that it has been placed or installed in its intended normal operating position and they have been given supervision or instruction concerning use of the appliance in a safe way and understand the hazards involved.
  • Children aged from 3 years and less than 8 years shall not plug in, regulate and clean the appliance or perform user maintenance.

CAUTION — Some parts of this product can become very hot and cause burns. Particular attention has to be given where children and vulnerable people are present.

Get In Touch
Call: 0845 6880112
Email: info@adremit.co.uk

Our Address
Puravent, Adremit Limited, Unit 5a, Commercial Yard, Settle, North Yorkshire, BD24 9RH

Main office
Frico AB
Tel: +46 31 336 86 00
Industrivägen 41
SE-433 61 Sävedalen
Email: mailbox@frico.se
Sweden
Website: www.frico.net
For latest updated information and information about your local contact: www.frico.net

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals