Completely read through the operating instructions, the „Warranty and Additional Information“ booklet as well as the latest information under the internet link at the end of these instructions. Follow the instructions they contain. This document must be kept in a safe place and if the laser device is passed on, this document must be passed on with it.
Function / Application
The ThermoSpot One is a contactless infrared temperature measuring device with
an integrated laser. Non-contact temperature measurement of surfaces is
realized by measuring and evaluating the amount of electromagnetic energy in
the infrared wavelength range.
General safety instructions
– The device must only be used in accordance with its intendedpurpose and
within the scope of the specifications.
– The measuring tools and accessories are not toys. Keep out of reach of
children.
– Modifications or changes to the device are not permitted, this will
otherwise invalidate the approval and safety specifications.
– Do not expose the device to mechanical stress, extreme temperatures,
moisture, or significant vibration.
– The device must no longer be used if one or more of its functions fail or
the battery charge is weak.
– Please ensure compliance with the safety regulations set out by local and
national authorities with regard to the correct and proper use of the device.
Safety instructions
Using class 2 lasers
Laser radiation! Do not stare into the beam! Class 2 laser < 1 mW · 650 nm EN
60825-1:2014/AC:2017
– Attention: Do not look into the direct or reflected beam.
– Do not point the laser beam towards persons.
– If a person‘s eyes are exposed to class 2 laser radiation, they should shut
their eyes and immediately move away from the beam.
– Under no circumstances should optical instruments (magnifying glass,
microscope, binoculars)
– Do not use the laser at eye level (1.40…1.90 m).
– Tampering with (making changes to) the laser device is not permitted.
Dealing with electromagnetic radiation
– The measuring device complies with electromagnetic compatibility regulations
and limit values in accordance with EMC-Directive 2014/30/EU.
– Local operating restrictions – for example, in hospitals, aircraft, petrol
stations, or in the vicinity of people with pacemakers – may apply. Electronic
devices can potentially cause hazards or interference or be subject to hazards
or interference.
– The measuring accuracy may be affected when working close to high voltages
or high electromagnetic alternating fields.
Information on maintenance and care
clean all components with a damp cloth and do not use cleaning agents,n
scouring agents, and solvents. Remove the battery(ies) before storing for
longer periods. Store the device in a clean and dry place.
Calibration
The meter needs to be calibrated and tested on a regular basis to ensure it
produces accurate measurement results. We recommend carrying out calibration
once a year.
a. Laser beam switched on
b. Battery charge
c. Hold function
d. Measured value display
e. Max. the value during the measurement
f. Display lighting
g. Unit of measurement °C / °F
Laserliner
To set the required temperature unit, press and hold the „°C/°F“ button until the corresponding symbol appears on the display.
Continuous measurement / Hold
For continuous measurement activate the laser (see figure) and keep the button
pressed.
Release the button as soon as the target laser pinpoints the measurement location. nThe measured value is held.
Measurement procedure notice
This infrared temperature instrument detects the temperature of various
surfaces and materials. A built-in sensor head detects the material-specific
infrared rays emitted by every object. The amount of these emissions is
determined by the material‘s emission coefficient (0 … 1). This instrument is
permanently set to an emission coefficient of 0.95, which is applicable to
most organic materials as well as plastics, ceramics, wood, rubber, and stone.
Please ensure that the space between the instrument and surface to be measured
is free of disturbances (steam, gas, contamination, glass).
Laser
The laser is a targeting aid to sight the location for the infrared
measurement. Only the surface‘s temperature is measured. Set the optimum
measuring distance for the measured spot (12:1) such that it is completely
within the target object.
Technical data
Measurement range
|
-38°C … 365°C (-36.4°F 689°F)
---|---
Accuracy| 2.5°C + 0.05°C / degree
(-38°C … 0°C)
2.5°C (0°C … 365°C) or
*2.5 % whichever value is greater
Optic| 12:1 (distance : measured spot)
Resolution| 0.2 °C
Emission coefficient| 0.95
Laser wavelength| 650 nm
Laser class| 2, < 1 mW
Operating conditions| 0°C … 50°C, max. humidity 20…85% RH, no condensation,
max. working altitude 4000 m above sea level
Storage conditions| -10°C … 60°C,max. humidity 80% RH
Relative humidity| 20% RH … 80% RH, no condensation
Power supply| 2 x 1.5V alkaline batteries (type AAA)
Dimensions (W x H x D)| 40 x 155.5 x 113 mm
Weight (incl. batteries)| 173 g
EU directives and disposal
This device complies with all necessary standards for the free movement of
goods within the EU. This product is an electric device and must be collected.
separately for disposal according to the European Directive on waste
electrical and electronic equipment. Further safety and supplementary notices
at:
http://laserliner.com/info?an=AFY
SERVICE
Umarex GmbH & Co. KG
– Laserliner –
149, 59755 Arnsberg, Germany
Tel.: +49 2932 638-300, Fax: +49 2932 638-333
info@laserliner.com
Umarex GmbH & Co. KG
Sonnenfeld 2
59757 Arnsberg, Germany ****
Tel.: +49 2932 638-300, Fax: -333
www.laserliner.com
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>