CROWN GLTS-30 Gas Power Tilt Skillets Installation Guide
- June 6, 2024
- CROWN
Table of Contents
Installation & Operation Manual
Gas Power Tilt Skillets
Model GLTS-40
GLTS-30 & GLTS-40
IMPORTANT FOR FUTURE REFERENCE
Please complete this information and retain this manual for the life of the
equipment:
Model #:
Serial #:
Date Purchased: _____
WARNING
Improper installation, adjustment, alteration, service or maintenance can
cause property damage, injury or death. Read the installation, operating, and
maintenance instructions thoroughly before installing or servicing this
equipment.
CROWN FOODSERVICE EQUIPMENT
A Middleby Company
70 Oakdale Road, Downsview (Toronto) Ontario, Canada, M3N 1V9
Telephone: 919-762-1000
www.crownsteamgroup.com
MANUAL 10100 REV 0 (04/21)
$21.00
GAS POWER TILT SKILLETS
SAFETY PRECAUTIONS
Before installing and operating this equipment, be sure everyone involved in
its operation is fully trained and aware of precautions. Accidents and
problems can be caused by failure to follow fundamental rules and precautions.
The following symbols, found throughout this manual, alert you to potentially
dangerous conditions to the operator, service personnel, or to the equipment.
DANGER
This symbol warns of immediate hazards that will result in severe injury or
death.
WARNING
This symbol refers to a potential hazard or unsafe practice that could result
in injury or death.
CAUTION
This symbol refers to a potential hazard or unsafe practice that could result
in injury, product damage, or property damage.
NOTICE
This symbol refers to information that needs special attention or must be
fully understood, even though not dangerous.
IMPORTANT NOTES FOR INSTALLATION AND OPERATION
WARNING
This is the safety alert symbol. It is used to alert you to potential personal
injury hazards. Obey all safety messages that follow this symbol to avoid
possible injury or death.
WARNING
FOR YOUR SAFETY:
Do not store or use gasoline or other flammable vapors or liquids in the
vicinity of this or any other appliance.
WARNING
Improper installation, operation, adjustment, alteration, service or
maintenance can cause property damage, injury or death. Read the installation,
operating and maintenance instructions thoroughly before installing, operating
or servicing this equipment.
NOTICE
This product is intended for commercial use only. NOT FOR HOUSEHOLD USE.
NOTICE
This manual should be retained for future reference.
PURCHASER: Instructions to be followed in the event the operator of this
appliance smells gas must be posted in a prominent location. This information
shall be obtained by consulting the local gas supplier.
Keep the appliance area free and clear from combustibles.
DO NOT obstruct the flow of combustion and ventilation air.
Adequate clearances MUST be maintained for servicing and proper operation.
Contact the factory, the factory representative or a local service company to
perform maintenance and repairs should the appliance malfunction. Refer to
warranty terms.
Copyright © 2021 by Crown. All rights reserved. Published in the United States of America.
SERVICE CONNECTIONS
– Unless otherwise specified, Field Wire Electrical Connection to be 120 Volts, 60 Hz, single phase with grounding wire. Unit furnished with 6’ cord and 3 prong plug. Total max amps 4.0.
– GAS CONNECTION: Supply gas through a 3/4” pipe.
– COLDWATER: 3/8” O.D. tubing to optional faucet
– HOT WATER: 3/8” O.D. tubing to optional faucet
DIMENSIONS
MODEL | CAPACITY | UNITS | A | B | C | D | E | F | G | H | J | K |
---|---|---|---|---|---|---|---|---|---|---|---|---|
Ø2 | Ø3 | |||||||||||
GLTS-30 | 30 Gallons | inches | 36′ | 33.88′ | 72.25″ | 33.5″ | 23.5″ | 39.50″ | 4″ | |||
6′ | 3.75″ | 42.88″ | 48.5′ | |||||||||
(114 liters) | (millimeters) | (914 mm) | (860 mm) | (1835 mm) | (851 mm) | (597 | ||||||
mm) | (1003 mm) | (102 mm) | (152 mm) | (95 mm) | (1089 mm) | (1232 mm) | ||||||
GLTS-40 | 40 Gallons | inches | 48″ | 45.88″ | 71.75″ | 43.5″ | 23″ | 39.88″ | 4″ | 6″ | ||
4.75″ | 42.88″ | 48.5″ | ||||||||||
(152 liters) | (millimeters) | (1219 mm) | (1165 mm) | (1822 mm) | (1105 mm) | |||||||
(584 mm) | (1013 mm) | (102 mm) | (152 mm) | (121 mm) | (1089 mm) | (1232 mm) |
GAS CHARACTERISTICS
Mom| SHIPPING
WEIGHT| GAS SUPPLY| MINIMUM CLEARANCE’
---|---|---|---
BTU/HR| kW/HR| Supply Pipe Pressure (W.C)
GLTS-30| 0l
55bs.
[249 kg]| 80.000| 23.| Natural
6″- 14′
(152 mm – 356 mm)| Propane
11″- 14″
(279 mm – 356 mm)| Sides| 3″ (76 mm)
GLTS-40| 736 lbs.
[334 kg]| 100,000| 29.| Back| 6″ (152 mm)
- For use on non-combustible floors only.
INSTALLATION INSTRUCTIONS
UNPACKING
IMMEDIATELY INSPECT FOR SHIPPING DAMAGE
Immediately after unpacking the steamer, check for possible shipping damage.
If the steamer is found to be damaged, save the packaging material and contact
the carrier within 15 days of delivery.
Prior to installation, verify that the type of gas supply (natural or propane)
and electrical service agree with the specifications on the rating plate
located on the left side panel as you face the front of the braising pan. If
the supply and equipment requirements do not agree, contact your dealer
immediately.
Location
The equipment must be kept free and clear of combustible substances. The
tilting braising pan, when installed, must have minimum clearance from
combustible and non-combustible construction of 3” (76 mm) from sides and 6”
(152 mm) from the rear. The tilting braising pan is intended for use on non-
combustible floors.
The installation location must allow adequate clearances for servicing and
proper operation. A minimum front clearance of 36” (914 mm) is required.
The tilting braising pan must be installed so that the flow of combustion and
ventilation air will not be obstructed. Adequate clearance for air openings
into the combustion chamber must be provided. Make sure there is an adequate
supply of air in the room suitable for the amount of combustion gas feeding
the braising pan burners.
Do not permit fans to blow directly at the tilting braising pan, and wherever
possible, avoid open windows next to the tilting braising pan. Avoid wall-type
fans which create air cross-currents within the room.
Installation Codes and Standards
Installation must conform with local codes, or in the absence of local codes,
with the National Fuel Gas Code, ANSI Z223.1INFPA 54, or the Natural Gas and
Propane Installation Code, CSA B149.1, as applicable.
- The appliance and its individual shut-off valve must be disconnected from the gas supply piping system during any pressure testing of that system at pressures in excess of 1/2 psi (3.5 kPa).
- The appliance must be isolated from the gas supply piping system by closing its individual manual shut-off valve during any pressure testing of the gas supply piping system at test pressures equal to or less than 1/2 psi (3.5 kPa).
Electrical grounding must be provided in accordance with local codes, or in
the absence of local codes, with the National Electrical Code, ANSI/NFPA 70,
or the Canadian Electrical Code, CSA C22.2, as applicable.
Ventilation must be provided in accordance with local codes, or in the absence
of local codes, with ANSI/NFPA 96 Standard for Ventilation and Fire Protection
of Commercial Cooking Operations.
Flue Connections
Do not obstruct the flow of flue gases from the flue duct located on the rear
of the tilting braising pan. It is recommended that the flue gases be
ventilated to the outside of the building through a ventilation system
installed by qualified personnel.
Information on the construction and installation of ventilating hoods may be
obtained from the standard for “Vapour Removal from Cooking Equipment”, NFPA
No. 96 (latest edition), available from the National Fire Protection
Association, Batterymarch Park, Quincy, MA, 02269.
WARNING
ELECTRICAL GROUNDING INSTRUCTIONS
This appliance is equipped with a three-prong (grounding) plug for your
protection against shock hazards and should be plugged directly into a
properly grounded three-prong receptacle. Do not cut or remove the grounding
prong from this plug. (120V units only).
Leveling and Anchoring
- Set the appliance in place and level left to right and front-to-back using a spirit level.
- Mark hole locations on the floor through anchoring holes provided in flanged adjustable feet.
- Remove the appliance and drill holes in locations marked on the floor and insert proper anchoring devices (not supplied).
- Set unit back in position and re-level left to right and front to back.
- Bolt and anchor appliance securely to the floor.
- Seal bolts and flanged feet with Silastic or equivalent compound.
Gas Connections
WARNING
Do not connect the appliance to the electrical supply until after the gas
connection has been made.
CAUTION
The pipe thread compound used when installing pipes must be a type that is
resistant to the action of liquified petroleum or propane gases.
All gas supply connections and any pipe joint compound used must be resistant
to the action of propane gases.
The gas inlet is located under the control panel on the left-hand side.
Connect gas supply to the tilting braising pan. The gas supply line must be at
least the equivalent of 3/4” iron pipe with an incoming pressure of
approximately 7” W.C. (Water Column) for natural gas or 11” W.C. (Water
Column) for propane gas.
Make sure the pipes are clean and free of obstructions, dirt and piping
compound.
Codes require that a gas shutoff valve be installed in the gas line ahead of
the tilting braising pan.
Natural gas and propane gas braising pans are equipped with fixed orifices and
no adjustment is necessary. The gas burner manifold is set at 3.5” W.C. (Water
Column) for natural gas, and 10” W.C. (Water Column) for propane gas.
WARNING
Never use an open flame to check for gas leaks. Check all connections for
leaks using soapy water before use.
After the piping has been checked for leaks, all piping receiving gas should
be fully purged to remove air.
NOTICE
If this equipment is being installed at over 2,000 feet altitude and was not
so specified on order, contact the service department. Failure to install with
proper orifice sizing may void the warranty.
OPERATION
NOTICE
If this equipment is being installed at over 2,000 feet altitude and was not
so specified on order, contact the service department. Failure to install with
proper orifice sizing may void the warranty.
Before First Use
Using a non-corrosive, grease-dissolving commercial cleaner, clean the
protective metal oils from all surface parts and the interior of the tilting
braising pan. Follow the cleaner manufacturer’s directions. Rinse thoroughly
and drain the pan. Wipe dry with a soft clean cloth.
CONTROLS (figure 1)
Green Ignition Light …………. Will light when the ignition has occurred.
Red Temperature Light …….. Will light when burners are supplying heat to the
tilting braising pan.
Thermostat ………………………. When turned ON, will initiate an electronic ignition
system. Temperature settings range from 1 to 10. (See COOKING GUIDELINES in
this manual for temperature ranges for settings 1-10.)
Tilt Switch ………………………… Push UP to raise tilting braising pan; push DOWN to
lower tilting braising pan.
Start-up Procedure
-
Open manual gas shutoff valve.
-
Ensure that the braising pan is in the DOWN position.
-
Turn on the power switch.
-
Turn the THERMOSTAT dial to the desired setting. The red TEMPERATURE LIGHT will come on. This will turn on the
electronic ignition which will light the burners.
If the green IGNITION LIGHT does not come on after 30 seconds, turn THERMOSTAT OFF and then ON again for restart. -
When braising pan has reached set temperature, the red TEMPERATURE LIGHT will go off and the burners will shut off. The burners will cycle on and off thereafter to maintain the set temperature. The red TEMPERATURE LIGHT will be on when the burners are on and off when burners are off.
-
If gas supply is interrupted during operation, turn THERMOSTAT dial to OFF position and turn gas supply OFF. Wait for 5 minutes, then repeat Steps 1 through 4 to restart.
-
Turn power switch and THERMOSTAT to OFF when braising pan is not in use.
CAUTION
If you smell gas during the lighting procedure, immediately shut off the gas
supply until the leak has been corrected.
WARNING
In the event of main burner ignition failure, a 5 minute purge period must be
observed prior to re-establishing the ignition source.
Daily Shutdown Procedure
Turn THERMOSTAT dial to OFF. Close manual gas shutoff valve.
Tilting the Braising Pan
-
DO NOT try to tilt braising pan with lid down.
-
Make sure the receiving pan is in place.
-
To tilt braising pan, push and hold TILT SWITCH in the UP mode until desired pan position has been reached. The braising pan will empty when raised to the top tilt position.
When the braising pan is raised 5E or more, the gas supply will be turned off automatically. The braising pan will not operate once the pan has been tilted. -
Food is poured through the removable strainer (Figure 2) into a food receiving pan positioned under the lip of the pouring spout (Figure 2).
-
To lower braising pan, push and hold TILT SWITCH in the DOWN mode.
NOTICE
Excessive, consecutive lifts may cause the motor to overheat and activate the
thermal overload causing the motor to shut down.
Should this occur, a cooling-off time will be necessary to reset and continue
the lifting operation.
Preventative Maintenance
WARNING
Disconnect the power supply to the appliance before cleaning or servicing.
CAUTION
Do not use cleaning agents that are corrosive.
CAUTION
Operating, testing, and servicing should only be performed by qualified
personnel.
Cleaning
After each use, allow the tilting braising pan to cool and clean it. Keep
exposed cleanable areas of the tilting braising pan clean at all times. Do not
get water in the electrical box or any electrical component.
-
Thoroughly wash pan, pouring spout (See Figure 2), lid, and exterior surfaces with detergent and warm water.
If necessary, soak pan to remove food that is stuck to pan surface. Rinse thoroughly and wipe dry with a soft clean cloth. -
Clean the removable strainer and receive pan support (see Figure 2) with detergent and warm water. Rinse thoroughly and wipe dry with a soft clean cloth.
-
Clean around burner air mixers and orifices (at rear of the burner) if lint has accumulated.
-
Visually ensure tube lighter ports (Figure 3) are unobstructed.
CAUTION
The appliance and its parts are hot. Use care when operating, cleaning, and
servicing the appliance.
WARNING
Disconnect the power supply to the appliance before cleaning or servicing.
Adjustments
All tilting braising pans are adjusted at the factory.
At least twice a year, have an authorized service person clean and adjust the
tilting braising pan for maximum performance.
COOKING GUIDELINES
The guidelines given below are suggested quantities, temperature settings, and
estimated numbers of orders per load and per hour. When two temperatures are
given, the first is to start the product, and the second to finish the
product.
The following temperatures should be used:
COOKING METHOD | TEMPERATURE (°F) | Thermostat Setting |
---|---|---|
Simmering | 200 Maximum | 1 – 4 |
Sautéing | 225 – 275 | 5 – 6 |
Searing | 300 – 350 | 7 – 8 |
Frying | 325 – 375 | 8 – 9 |
Grilling | 350 – 450 | 9 -10 |
ITEM | PORTION | |
SIZE | ‘WW1) | , |
PER HOUR | GLTS-30 PER LOAD | GLTS-40 PER LOAD |
--- | --- | --- |
CITY, I | PORTIONS | QTY. I |
BREAKFAST FOODS
Bacon| 3 slices| 350| 12| 21b| 10| 3 lb| 15
Eggs
– Boiled Hard| 1 egg| 225| 5| 50 eggs| 50| 75 eggs| 75
– Boiled-Soft| 1 egg| 225| 8| 50 eggs| 50| 75 eggs| 75
– Fried| 1 egg| 400| 4| 30 eggs| 30| 45 eggs| 45
– Poached| 1 egg| 225| 5| 36 eggs| 36| 60 eggs| 60
– Scrambled| 1-12 eggs| 300-200| 1| 18 gal.| 720| 28 gal.| 1100
French Toast| 3 slices| 450| 7| 35 slices| 12| 50 slices| 17
Regular Oatmeal| 1/2 cup| 250| 2| 201b (100 cups)| 500| 40 lb (200 cups)| 1000
Pancakes| 2 each| 400| 10| 30 each| 15| 50 each| 25
FISH
Clams| 1 pint| 400| 10| 10 quarts| 20| 15 quarts| 30
Fish Cakes| 2 – 3 oz| 400| 5| 70 – 3 oz| 35| 110 – 3 oz| 55
Haddock Fillet| 4oz| 400| 4| 60 – 4 oz| 60| 90 – 4 oz| 90
Halibut Steak| 5 oz| 450| 3| 60 – 4 oz| 60| 90 – 4 oz| 90
Lobster| 1 – 1 lb| 350| 4| 20. 1 lb| 20| 30 -1 lb| 30
Swordfish| 5 oz| 450| 3| 50 – 5 oz| 50| 75.5 oz| 75
SAUCES, GRAVIES, SOUPS
Brown Gravy| 1 oz| 350 – 200| 2| 18 gal.| 2300| 35 gal.| 4500
Cream Sauce| 2 oz| 250 – 175| 1| 18 gal.| 1150| 35 gal.| 2250
Cream Soup| 6 oz| 200| 1| 18 gal.| 375| 35 gal.| 725
French onion soup| 6 oz| 225| 1| 18 gal.| 350| 35 gal.| 700
Meat Sauce| 4oz| 350 – 200| 1| 18 gal.| 575| 35 gal.| 1100
VEGETABLES
CANNED| 3oz| 400| 6| 301b| 125| 45 lb| 200
FRESH
Beans. Wax. Green| 3oz| 400| 3| 25 lb| 125| 501b| 250
Beets| 3oz| 400| 1| 30 lb| 125| 601b| 300
ITEM| PORTION SIZE| TEMP4°F)| BATCHES
PER HOUR| GLTS-30 PER LOAD| GLTS-40 PER LOAD
---|---|---|---|---|---
QTY.| I PORTIONS| CITY.| PORTIONS
VEGETABLES (continued)
FRESH (continued)
Broccoli| 3 oz| 400| 3| 25 lb| 125| 40 lb| 200
Cabbage| 3 oz| 400| 5| 20 lb| 80| 301b| 125
Carrots| 3 oz| 400| 2| 35 lb| 150| 70 lb| 300
Cauliflower| 3 oz| 250| 5| 15 lb| 75| 25 lb| 125
Can| 1 ear| 400| 8| 50 ears| 50| 75 ears| 75
Potatoes| 3 oz| 400| 2| 401b| 200| 60 lb| 300
Spinach| 4 oz| 250| 10| 401b| 200| 9 lb| 35
Turnips| 4 oz| 400| 2| 201b| 100| 301b| 150
FROZEN
Beans, FrenchGreen| 3 oz| 400| 6| 15 lb| 60| 22-1/2 lb| 90
Lima Beans| 3 oz| 250| 4| 151b| 60| 22-1/21b| 90
Broccoli| 3 oz| 400| 8| 12 lb| 50| 181b| 75
Sliced Carrots| 3 oz| 250| 6| 15 lb| 60| 22-1/21b| 90
Small WholeCarrots| 3 oz| 250| 3| 151b| 50| 22-1121b| 90
Corn| 3oz| 250| 18| 15 lb| 50| 22-1/21b| 90
Small WholeOnions| 3oz| 250| 7| 151b| 50| 22-1/21b| 90
Peas| 3oz| 400| 10| 151b| 75| 22-1/21b| 110
Spinach| 3oz| 400| 3| 151b| 75| 22-1/21b| 110
DESSERTS, PUDDINGS, SWEET SAUCES
ButterscotchSauce| 1 oz| 200| 1| 18 gal.| 2300| 35 gal.| 4500
Cherry Cobbler| 3 oz| 200| 1| 18 gal.| 750| 35 gal.| 1500
Chocolate Sauce| 1 oz| 200| 1| 18 gal.| 2300| 35 gal.| 4500
ComstarchPudding| 4 oz| 200| 1| 18 gal.| 575| 35 gal.| 1100
Fruit Gelatin| 3 oz| 250| 2| 18 gal.| 750| 35 gal.| 1500
MEAT-POULTRY
BEEF
American ChopSuey| 6 oz| 400 – 225| 2| 18 gal.| 350| 35 gal.| 700
Beef Stew| 8 oz| 300| –| 18 gal.| 280| 35 gal.| 560
Corned BeelHash| 5 oz| 400| 5| 161b| 50| 25 lb| 75
Cheeseburger| 3 oz| 300| 12| 7 lb| 35| 10Ib| 50
Hamburger| 3 oz| 300| 15| 7 lb| 35| 10Ib| 50
Meatballs| 1 oz| 400 – 225| 3| 12-112 lb| 65| 18lb| 100
Pot Roast| 2 oz| 350 – 200| | 120 lb| 500| 180th| 750
Salisbury Steak| 5 oz| 400| 3| 16 lb| 50| 24 lb| 75
Sirloin Steak| 6 oz| 400| 5| 15 lb| 40| 22-1/2 lb| 60
Swiss Steak| 4 oz| 300 – 200| 1| 25 lb| 110| 401b| 160
CHICKEN
Pan-Fried| 2-1/4%| 350| 3| 50 pieces| 25| 80 pieces| 40
Whole| 2 oz| 350 – 200| | 16 – 5 lb| 200| 24-5 lb| 265
ITEM| PORTION SIZE| TEMP4°F)| BATCHES
PER HOUR| GLTS-30 PER LOAD| GLTS-40 PER LOAD
---|---|---|---|---|---
QTY.| PORTIONS| QTY.| PORTIONS
MEAT-POULTRY (continued)
FRANKFURTERS
Grilled| 2 oz| 300| 8| 22 lb| 176| 331b| 264
Boiled| 2 oz| 250| 12| 16 lb| 128| 251b| 200
PORK
Bacon| 3 slices| 350| 12| 21b| 10| 31b| 15
Ham Steak| 3 oz| 400| 8| 10 lb| 50| 151b| 75
Pork Chops| 5 oz| 350| 4| 151b| 50| 251b| 75
Sausage Links| 3 links| 350| 7| 301b| 120| 451b| 180
TURKEY
Off Carcass| 2 oz| 400 – 200| —| 3 – 26-30 lb| 200| 4 – 26301b| 275
On Carcass| 2 oz| 400 – 200| —| 4- 16-20 lb| 175| 6 – 16-20 lb| 265
MISCELLANEOUS
Grilled Cheese Sandwich| 1 sandwich| 400| 8| 35 sandwiches| 35| 50 sandwiches|
50
Macaroni & Cheese| 8 oz| 200| 2| 18 gal.| 300| 35 gal.| 525
Rice| 4 oz| 350 – 225| 1| 20 lb raw| 320| 40 lb raw| 650
Spaghetti| 4 oz| 350 – 225| 2| 8 lb raw| 200| 12 Ibraw| 300
TROUBLESHOOTING
Burners No Not Come On
- Gas supply to unit is “OFF”.
- The manual shut-off valve is “OFF”.
- The thermostat is not turned “ON”.
- Pan not in lowest position.
- Ignition control not functioning.
- Unit electrical supply is not plugged in or turned on.
Burners Produce Carbon Deposits
- Wrong size orifices.
- Burner air not adjusted properly.
- Wrong gas supply.
- Incorrect pressure at supply.
NOTICE
Contact the factory, the factory representative or local service company to
perform maintenance and repairs.
Notes
GLTS-30 & GLTS-40
Gas Power Tilt Skillets
A product with the Crown name incorporates the best in durability and low maintenance. We all recognize, however, that replacement parts and occasional professional service may be necessary to extend the useful life of this appliance. When service is needed, contact a Crown Authorized Service Agency, or your dealer. To avoid confusion, always refer to the model number, serial number, and type of your appliance.
CROWN FOODSERVICE EQUIPMENT
A Middleby Company
70 Oakdale Road, Downsview (Toronto) Ontario, Canada, M3N 1V9
Telephone: 919-762-1000
www.crownsteamgroup.com
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>