CROWN CT44047 Digital Measuring Line Laser Instruction Manual

October 30, 2023
CROWN

CROWN logo TOOLS FOR A BETTERY LIFE
CT44046, CT44047 Digital Measuring Line Laser”
Instruction Manual

CT44047 Digital Measuring Line Laser

CROWN CT44047 Digital Measuring Line Laser - SymbolCROWN CT44047 Digital Measuring Line Laser - Figure
1![CROWN CT44047 Digital Measuring Line Laser

Technical data

Line laser CT44046 CT44047
Appliance code 425041 425058
Projected beams 1V 1H 1V 1H
Max. working range [m] 15 30
Levelling accuracy:
– horizontal beam ±3 mm at 10 m ±3 mm at 10 m
– vertical beam ±3 mm at 10 m ±3 mm at 10 m
Self-leveling time [s] ≤4 ≤4
Self-leveling range ±4° ≤4
Laser class II II
Laser type [nm] 635 520
Battery type 4 x AA 4 x AA
Thread for tripod 1/4″ 1/4″
Operating temperature range [°C] -10 … +40 -10 … +40
Storage temperature range [°C] -20 … +55 -20 … +55
Weight [kg] [lb] 0,26 0,26
0.57 0.57
  • V – vertical plane, H – horizontal plane.
    Declaration of conformity
    We declare under our sole responsibility that the product described under “Technical data” is in conformity with all relevant provisions of the directives 2006/42/EC including their amendments and complies with the following standards:
    IEC 60825-1:2014.
    Certification manager
    Wu Cunzhen
    Merit Link International AG
    Stabio, Switzerland, 30.05.2019

General safety rules

WARNING – To reduce the risk of injury, user must read instruction manual!
ATTENTION! Before using the appliance for the first time, read this manual carefully and follow all its recommendations and rules. Keep the manual for future reference or for the next owner.

  • Before using, check the appliance housing integrity; in case of any damages the appliance must not be used.

  • Do not direct a laser beam at people or animals, and do not look at a straight or reflected laser beam. A laser beam can blind people, cause an accident or damage eyes. It is strictly forbidden to look at the laser beam through optical appliances (binoculars,  telescopes, etc.), this can cause damage to the retina.

  • Do not operate the appliance in atmospheres containing explosive gases, dust or vapours.

  • When working be aware of the factors which may cause wrong measurement results:
    • contamination of laser emitter window;
    • measurement through transparent objects (windows, aquariums, etc.);
    • measurement on reflective surfaces (mirrors, polished metal surfaces, etc.);
    • presence of steam, dust, smoke, etc. in the air.

  • Do not expose the appliance to moisture, and do not allow moisture enter the appliance. Do not immerse the appliance into liquid.

  • Do not drop or knock the appliance.

  • Protect the appliance against electromagnetic fields (for example, fields from electric arc welding or induction heaters).

  • In case of sudden changes in ambient temperature, do not use the appliance for at least 30 minutes.

  • Do not leave the appliance near objects with high temperature.

Appliance maintenance
Maintenance of your appliance must be performed by qualified personnel using the recommended spare parts. This ensures that the safety of your appliance will be preserved.
Symbols used in the manual
Following symbols are used in the operation manual, please remember their meanings. Correct interpretation of the symbols will allow correct and safe use of the appliance.

Symbol Meaning
Read all safety regulations and instructions.
Caution! Laser radiation.
Movement direction.
Rotation direction.
Locked.
Unlocked.
**** A sign certifying that the product complies with essential requirements

of the EU directives and harmonized EU standards.
| Attention. Important.
| Useful information.
****| Do not dispose of the appliance in a domestic waste container.

Intended use

Line laser is intended to draw and / or control horizontal, vertical and inclined lines.
Components

  1. Indicator
  2. Laser beams on / off switch
  3. Emitter window
  4. Laser head position lock
  5. Spring clamp with swivel holder *
  6. Storage bag *
  7. Carrying bag *
  8. Locking nut *
  9. Battery case cover
  10. Battery (AA type) *
  11. Locking screw *
  • Optional extra
    Not all of the accessories illustrated or described are included as standard delivery.

Installation / regulation

**** Do not draw up the fastening elements too tight to avoid damaging the thread.
Mounting / dismantling / adjustment of some elements is similar for all appliance models. In this case no particular appliance model is indicated in the explanatory drawing.
Mounting / dismounting of spring clamp with swivel holder (see fig. 1)
Fig. 1 shows spring clamp with swivel holder 5 mounting / dismounting operations.
Installation / replacement of the batteries (see fig. 2)
If indicator 1 lit red and blinking, it indicates the batteries 10 should be replace.

  • Open cover 9 (see fig. 2).

  • Install / replace batteries 10 (AA type).
    Caution: during installation of batteries 10, observe correct polarity.

  • Close cover 9.

Switching on / off
When self-levelling is on
Switching on:
Set lock 4 to position as shown in fig. 3.1. This will unlock the suspension gear of the laser head and turn power of laser beam. If self-leveling of laser head successful indicator 1 lit green. If self-leveling of laser head unsuccessful indicator 1 lit red and laser beams blinked. You can switch on and off the laser beams pressing on / off switch 2.
Switching off:
Set lock 4 to position as shown in fig. 3.2. This will lock the suspension gear of the laser head, turn power of laser off.
When self-levelling is off
Switching on:
Set lock 4 to position as shown in fig. 3.2, then press and release on / off switch 2. Laser power is now on, but the suspension gear of the laser head is locked. Indicator 1 lit red and laser beams blinked. You can switch on and off the laser beams pressing on / off switch 2.
Switching off:
Press and release on / off switch 2.

Design features

Laser head self-levelling system
Laser head self-levelling system makes laser measurement possible, if the body of appliance not in vertical position (inclination angle not exceeding ±4°).
If maximum possible inclination angle is exceeded, indicator 1 lit red and laser beams start blinking.
Attention: if the appliance is moved during use, lock the laser head during storage and transportation (set lock 4 to the position shown in fig. 3.2).
Spring clamp with swivel holder (see fig. 4-5)
Spring clamp with swivel holder 5 allows to install the appliance on various objects (tables, chairs, pipes, etc.). The swivel holder allows to change the position of the appliance body in a wide range (see. fig. 4-5).

  • Loosen locking screw 11 (see fig. 4.1).
  • Change position of the appliance body (see fig. 5).
  • Tighten locking screw 11 (see fig. 4.2).

Working advice

Precision test
The appliance is ready for operation.
The accuracy of the appliance has been verified at the factory.
If measurement error exceeds maximum allowable variance during the precision test, please contact CROWN service centre.
Factors, influencing appliance precision:

  • Ambient temperature, e.g., temperature difference which may take place with distance from the ground. Temperature difference is most considerable near ground surface, therefore it is recommended to use the tripod for measurements in areas with length  exceeding 20 m.

  • Contamination of the laser emitter window.
    Always check protective windows for contaminations before use and clean them if necessary.

  • Measurement through transparent surfaces (windows, aquariums, etc.). It is not recommended to carry out such measurement.

  • Measurements on reflective surfaces (mirrors, polished metal surfaces, etc.).
    It is not recommended to carry out such measurement.

  • Presence of steam, dust, smoke, etc. in the air. It is not recommended to carry out such measurement.

  • Fall of the appliance or a heavy shock.
    In this case it is recommended to perform a precision test. If maximum allowable variance is exceeded, please contact CROWN service centre.

General recommendation (see fig. 6, 3)

  • Before starting work ensure that all measurements will be carried out under suitable conditions (see section “Factors, influencing appliance precision”).

  • Place the appliance correctly (indicator 1 should be lit green). If necessary, adjust the appliance position with swivel holder of spring clamp 5.

  • Turn on the appliance as described above. If you turn on the appliance with a laser head self-levelling on, but indicator 1 lit red and the laser beams blink, you have to re-position the appliance, otherwise the measurement results will be incorrect.

  • You can mark inclined lines when the laser head self-levelling is off (see fig. 6).
    Attention!
    Do not mark horizontal and vertical beams in this mode – their position is incorrect.

  • After finishing work turn off the appliance as described above (lock 4 shall be in the position as shown in fig. 3.2 and laser beams must be off).

  • It is recommended to put the appliance for long-term storage and transportation into bag 6. Ensure that there are no moisture drops on the appliance elements (if necessary, wipe with a soft cloth), after that put the appliance into bag 6.

Maintenance / preventive measures

Cleaning the appliance

  • Keep the appliance clean. Do not use caustic substances or solvents.
  • Emitter windows shall be cleaned with a soft cloth. Do not use sharp objects or corrosive agents for this purpose.

After-sales service and application service
Our after-sales service responds to your questions concerning maintenance and repair of your product as well as spare parts. Information about service centers, parts diagrams and information about spare parts can also be found under: www.crown-tools.com.
Transportation

  • Categorically not to drop any mechanical impact on the packaging during transport.
  • When unloading / loading is not allowed to use any kind of technology that works on the principle of clamping packaging.

Environmental protection

Recycle raw materials instead of disposing as waste.
Appliance, accessories and packaging should be sorted for environmentfriendly recycling.
The plastic components are labelled for categorized recycling.
These instructions are printed on recycled paper manufactured without chlorine.
The manufacturer reserves the possibility to introduce changes.

Merit Link International AG
P.O. Box 641, CH-6855 Stabio
Switzerland
www.meritlink.com

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>