NICOR IND299 LVT Series LED Volumetric T-Grid Luminaire Installation Guide

October 27, 2023
NICOR

IND299 LVT Series LED Volumetric T-Grid Luminaire
Installation Guide

BEFORE YOU BEGIN
Read these instructions completely and carefully.

WARNING

RISK OF ELECTRIC SHOCK

  • Turn power off before inspection, installation or removal.
  • Properly ground electrical enclosure.

RISK OF FIRE

  • Follow all NEC and local codes.
  • Use only UL approved wire for input/output connections. Minimum size 18 AWG (0.75mm2).

Save These Instructions
Use only in the manner intended by the manufacturer.
If you have any questions, contact the manufacturer.
Components Supplied

  • Luminaire

Tools and Components Required

  • Slot or Philips screwdriver
  • UL Listed conduit connections per NEC/CEC for nominal conduit trade sizes ½” or ¾”
  • UL Listed wire connectors

Prepare Electrical Wiring
Electrical Requirements

  • The LED luminaire must be connected to the mains supply according to its ratings on the product label.

Grounding Instructions

  • The grounding and bonding of the overall system shall be done in accordance with National Electric Code (NEC) Article 600 and local codes.

Luminaire Installation

  1. Carefully unpack unit from its packaging. Properly inspect for defects before installing. Wear work gloves to prevent dirt and oil from being transferred to the luminaire.NICOR IND299 LVT Series LED Volumetric T Grid Luminaire - Figure 1
  2. Install the unit into the reserved hole in the ceiling.NICOR IND299 LVT Series LED Volumetric T Grid Luminaire - Figure 2
  3. Bend the 4 clips to secure the luminaire in place. Install the safety cables through the holes on the clips (per local building codes, safety cables by others).NICOR IND299 LVT Series LED Volumetric T Grid Luminaire - Figure 3
  4. The diffuser panel is engaged over 4 screws on both ends of the LVT luminaire. It may become loose during shipping or if the Lumiere is significantly twisted during  install. It is important to make sure the diffuser is completely engaged to avoid having it fall out after the install is complete. Grasp diffuser and gently squeeze together to re-engage over screws.NICOR IND299 LVT Series LED Volumetric T Grid Luminaire - Figure 4

Electrical Connections

WARNING
Risk of electrical shock. Disconnect power before servicing or installing product.NICOR IND299 LVT Series LED Volumetric T Grid Luminaire - Figure
5

  1. Remove electrical enclosure cover. Remove knockout for AC line input wires.NICOR IND299 LVT Series LED Volumetric T Grid Luminaire - Figure 6
  2. Install listed electrical fittings in the knockout holes for wire protection. Connect the AC line to the luminaire internal wires according to the wiring diagrams using 1814AWG twist-on wire connectors.NICOR IND299 LVT Series LED Volumetric T Grid Luminaire - Figure 7
  3. Install listed electrical fittings in the knockout holes for wire protection. Connect the dimming control (grey and purple or purple and purple/white) wires of the LED driver using 18-14 AWG twist-on wire connectors.NICOR IND299 LVT Series LED Volumetric T Grid Luminaire - Figure 8
  4. Replace electrical enclosure cover and secure it with the screw.NICOR IND299 LVT Series LED Volumetric T Grid Luminaire - Figure 9

This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions:

  1. This device may not cause harmful interference, and
  2. This device must accept any interference received, including interference that may cause undesired operation. CAN ICES-005 (A) / NMB-005 (A)

Note: This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense.
Note: CONTACT FACTORY for details and limitations when seeking to incorporate this product with an emergency system other than Battery Backup.

www.gecurrent.com
© 2021 Current Lighting Solutions, LLC. All rights reserved.
GE and the GE monogram are trademarks of the General Electric Company and are used under license.
Information provided is subject to change without notice.
All values are design or typical values when measured under laboratory conditions.
IND299 (Rev 04/02/21)

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

NICOR User Manuals

Related Manuals