The RSDS-M Surface Mount Downlight with PIR Motion Sensor is a lighting solution that offers automatic on/off control and CCT selection (3000/4000/5000K) with the flip of a switch. It has a thin design and a twist lock diffuser that can be removed for easy installation. The direct box mount ensures a flush fit to the ceiling for a professional look. It is ideal for use in closets, pantries, and similar areas. It is available in two versions: RSD4 (600 lumen) and RSD6 (800 lumen).

Performance Data:

  • Model Number: RSD4SM-3000K
  • Lumens: 611
  • Watts: 9.74
  • Lumens/Watt: 62.7
  • CCTs: Selectable 3000/4000/5000K
  • Trim Color: White
  • Recommended Dimmers: Lutron Diva DVCL-153P, Lutron Maestro MACL-153M, Eaton Cooper SLC03P, Leviton IPL06, Lutron DIVA DVELV-300P
  • Housing Compatibility: Most 4 Pancake, 4 Non-Mettalic or 4/O junction boxes

Photometric Data:
The RSDS-M Surface Mount Downlight with PIR Motion Sensor has been tested per LM-79-08 standards. The following are the photometric data specifications:

RSD4SM 3000K:

  • Input Voltage (VAC): 120V
  • System Level Power (W): 9.8
  • Delivered Lumens (Lm): 611
  • System Efficacy (Lm/W): 62.3
  • Correlated Color Temp (K): 3005
  • Color Rendering Index (CRI): 91
  • Beam Angle: 109
  • Spacing Criteria: 1.24

RSD6SM 3000K:

  • Input Voltage (VAC): 120V
  • System Level Power (W): 14.5
  • Delivered Lumens (Lm): 832
  • System Efficacy (Lm/W): 57.4
  • Correlated Color Temp (K): 3057
  • Color Rendering Index (CRI): 92
  • Beam Angle: 113
  • Spacing Criteria: 1.26

Product Usage Instructions

  1. Choose the appropriate version of the RSDS-M Surface Mount Downlight with PIR Motion Sensor based on the desired lumens.
  2. Select the desired CCT (3000/4000/5000K) by flipping the appropriate switch.
  3. Ensure compatibility of the recommended dimmer and housing before installation.
  4. Twist the lock diffuser to remove it and reveal the mounting bracket.
  5. Screw the mounting bracket to the ceiling using the appropriate screws and anchors.
  6. Connect the wires to the junction box, following the wiring diagram provided in the user manual.
  7. Attach the fixture to the mounting bracket by aligning the pins and twisting it into place.
  8. Test the fixture by turning on the power and checking that it responds to motion.

Product Description

The RSDS-M Surface Mount Downlight with PIR Motion Sensor offers a thin installation solution that provides automatic on/off control. Select the CCT (3000/4000/5000K) with the flip of a switch. Installation is easier than ever with the twist lock diffuser that can be removed for installation. The direct box mount ensure it sits flush to the ceiling for a clean and professional look. Perfect for bringing even illumination with automatic controls to closets, pantries, and similar areas.

Construction

  • Durable aluminum body
  • Twist-lock diffuser allows for easy removal during installation

Optical System

  • Molded polymer, UV stabilized diffuser maximizes light output.
  • Convex diffuser creates uniform light distribution while reducing glare
  • Offered in 3CCT selection of 3000K, 4000K, and 5000K

Electrical

  • Input voltage of 120VAC, 60Hz
  • CCT switch located on back of fixture
  • Integrated PIR motion sensor. Automatic ON with 30-second wait time to OFF.
  • Dimmable to 5% with compatible leading edge (TRIAC) and trailing edge (ELV) dimmers
  • Operating temperature rating of -4°F to 104°F (-20°C to 40°C)

Finish

  • White powder coat finish standard

Mounting and Installation

  • Easy installation in any 4” pancake, 4” non-metallic or 4/O junction box
  • Keyhole mounting slots allow for quick installation to junction boxes
  • For installations where power surge may be possible, NICOR recommends installing additional surge protection at the electrical distribution panel

Listings

  • cETLus 1598 Listed for wet locations
  • ENERGYSTAR Listed
  • CA Title 24/JA8 Compliant
  • Compliant with NFPA® 70, NEC® Section 410.16 (A)(3) and 410.16 (C)(5) for closet use
  • RoHS Compliant
  • Meets FCC Part 15, Subpart B, Class B standards for conducted and radiated emissions
  • TM-21 Reported L70(9k) life >54,000 hours
  • LM-79, LM-80 testing performed in accordance with IESNA standards

Warranty

  • 5-year limited system warranty standard
  • Warranty does not cover product failure due to an overvoltage event (power surge)

Ordering Information

Ordering Information Example: RSD61120SWHM
Series Version Voltage CCT’s Trim Color

Sensor
RSD4| 1| 120| S (Selectable 3000/4000/5000K)| WH (White)| M (PIR sensor)
RSD6| | | | |

Specifications and dimensions subject to change without notice

Performance Data

Model Number/Lumens/Watts/Lumens/Watt

  • RSD4SM-3000K 611 9.74 62.7
  • RSD4SM-4000K 658 9.71 67.8
  • RSD4SM-5000K 620 9.73 63.7
  • RSD6SM-3000K 832 14.46 57.5
  • RSD6SM-4000K 988 15.55 63.7
  • RSD6SM-5000K 856 14.61 58.6

Recommended Dimmers

  • Lutron Diva DVCL-153P
  • Lutron Maestro MACL-153M
  • Eaton Cooper SLC03P
  • Leviton IPL06
  • Lutron DIVA DVELV-300P

Housing Compatibility
Most 4” Pancake, 4” Non-Metallic or 4/O junction boxes

Not a complete list. Check compatibility before installation.

Photometric Data

RSD4SM 3000K

  • Input Voltage (VAC) 120V
  • System Level Power (W) 9.8
  • Delivered Lumens (Lm) 611
  • System Efficacy (Lm/W) 62.3
  • Correlated Color Temp (K) 3005
  • Color Rendering Index (CRI) 91 R9=50
  • Beam Angle 109
  • Spacing Criteria 1.24

CCT Data Multiplier

  • 4000K 1.077
  • 5000K 1.014

NICOR-RSDS-M-Surface-Mount-Downlight-with-PIR-Motion-Sensor-
fig-1

Fixture tested per LM-79-08. Photometric data is of the performance of a representative fixture. Results may vary in the field.

RSD6SM 3000K

  • Input Voltage (VAC) 120V
  • System Level Power (W) 14.5
  • Delivered Lumens (Lm) 832
  • System Efficacy (Lm/W) 57.4
  • Correlated Color Temp (K) 3057
  • Color Rendering Index (CRI) 92 R9=54
  • Beam Angle 113
  • Spacing Criteria 1.26

CCT Data Multiplier

  • 4000K 1.188
  • 5000K 1.029

NICOR-RSDS-M-Surface-Mount-Downlight-with-PIR-Motion-Sensor-
fig-2

Fixture tested per LM-79-08. Photometric data is of the performance of a representative fixture. Results may vary in the field.

Dimensions and Sensor Information

NICOR-RSDS-M-Surface-Mount-Downlight-with-PIR-Motion-Sensor-
fig-3

NICOR-RSDS-M-Surface-Mount-Downlight-with-PIR-Motion-Sensor-
fig-4

FCC STATEMENT

This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions:

  1. This device may not cause harmful interference, and
  2. This device must accept any interference received, including interference that may cause undesired operation.

NOTE:
This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:

  • Reorient or relocate the receiving antenna.
  • Increase the separation between the equipment and receiver.
  • Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
  • Consult the dealer or an experienced radio/TV technician for help.

NICOR, Inc. 2200 Midtown Place NE, Albuquerque, NM 87107 P: 800.821.6283 F: 800.892.8393 www.nicorlighting.com January 31, 2023 2:00 PM RSDS-M.

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

NICOR User Manuals

Related Manuals