SYLVANIA 49136 T5HO Fluorescent Lamps Owner’s Manual
- October 27, 2023
- SYLVANIA
Table of Contents
49136 T5HO Fluorescent Lamps
Owner’s Manualz
49136 T5HO Fluorescent Lamps
QUICKTRONIC ® PROStart ® T5HO UNIVERSAL High Ambient Temp.
< 10% THD Electronic T5HO Fluorescent Programmed Rapid Start Ballasts
Lamp/Ballast Guide
54W T5 – PENTRON ® HO
1 or 2 lamp
QTP2x54T5HO/UNV PSN HT
QTP4x54T5HO/UNV PSN HT W
3 or 4 lamp
QTP4x54T5HO/UNV PSN HT W
Also operates:
FT55DL, FPC55, L58
Four lamp switchable model can be wired for four, three, two or one lamp
operation.
Two lamp fixed output model can be wired for one lamp operation.
Key System Features
- 90°C maximum case temp.
- Universal voltage (120-277)
- Low-profile (1.00″ High)
- 100% Ballast factor
- QUICKSENSE ballast technology (end-of-lamp-life sensing)
- PROStart programmed start
- Occupancy sensor applications
- UL type CC rated
- -20°F Starting
- Operates at >40 Khz to reduce potential interference with infrared control systems
- High power factor
- Low harmonic distortion
- Lightweight
- UL, CSA, FCC
Application Information
SYLVANIA QUICKTRONIC PHO
is ideally suited for:
• Industrial high-bay
• Commercial
• Retail
• Hospitality
• Institutional| • New construction
• Direct lighting
• Indirect lighting
• Surface mount
• Cove lighting
---|---
SYLVANIA QUICKTRONIC HIGH AMBIENT (HT) PHO
operates PENTRON HO, PENTRON HO Circline, and DULUX ® L T5 lamps with full
lumen output and optimal system performance.
SYSTEM PHO High Ambient Temperature ballasts are specifically designed for
applications where the ballast is subjected to higher ambient temperatures, as
in high bay industrial installations. The four lamp UNV (120277V) ballast
system provides 18,600 mean lumens, which, when factoring in lumen maintenance
and typical T5HO fixture
efficiency, can be considered as a direct replacement for standard 400W MH. As
such, the family is ideally suited to replace 250W and 400W metal halide
installations.
Unique to the family is the 120-277V 4-lamp “switching” ballast, designed to
switch from 4- to 3-, 3- to 2-, 3- to 1- or 2to 1-lamps. The switching feature
can be accessed through a second input power terminal.
This feature allows for a range ofcontrol interfaces, including an occupancy
sensor, mounted inside a fixture.
SYSTEM PHO HT ballasts contain QUICKSENSE ® ballast technology, a patented
circuitry designed to shut down the system reliably and safely when lamps
reach end-of-life.
Setting the standard for quality, SYSTEM PHO HT is also covered by our QUICK
60+ ® warranty, the first and most comprehensive system warranty in the
industry.
SYSTEM PHO HT is available in four and two lamp models to cover a wide range
of applications.
System Information
SYSTEM PHO HT operates on 120V through 277V, 50 or 60Hz current, eliminating
“wrong voltage” wiring errors and reducing the number of ballast models in
inventory
by half.
PROStart ballasts provide optimum starting conditions and provide up to
100,000 switching cycles for use on occupancy sensors and building control
systems.
QUICKSENSE ballast technology helps to protect against overheated bases and
sockets, as well as cracking of the lamp glass wall, and uses dynamic endof-
lamp-life sensing to avoid false shutdowns caused by some static sensing
methods.
QUICKSENSE ballast technology will auto reset when spent lamps are replaced
with new ones.
The four lamp unit can be wired for four, three, two or one lamp operation.
The two lamp unit can be wired for one lamp operation, allowing for an
additional 50% reduction in inventory model numbers.
SYSTEM PHO HT has a 25.4H (mm) profile. PENTRON T5 lamps are designed to provide peak performance at 35°C fixture ambient, allowing for smaller and more innovative fixtures.
System Type| Input Wattage| Initial Lumens| System
LPW
---|---|---|---
F40T12 – E.S. Magnetic Ballast (4-lamp)| 172| 11590| 67
F34T12 – E.S. Magnetic Ballast (4-lamp)| 144| 9500| 66
FO32T8/XP – QT4x32IS (4-lamp)| 114| 10800| 95
FP54T5 – QTP2x54T5HO/UNV PSN HT (2-lamp)| 121| 10000| 83
FP54T5 – QTP4x54T5HO/UNV PSN HTW (4-lamp)| 241| 20000| 83
PROStart ® T5HO UNV HIGH TEMP.
Fixed Output & Switchable
Specifications4
Starting Method: Programmed Start
Ballast Factor : 1.00
Circuit Type: Series
Lamp Frequency: > 40 KHz
Lamp CCF: Less than 1.6
Starting Temp: -20°F minimum5
Input Frequency: 50/60 Hz
Low THD : < 10%
Power Factor: > 98%
Voltage Range: +/–10% of Rated Input
UL Listed Class P, Type 1, Outdoor, Type CC
CSA Certified
High Ambient Applications: 90°C Max. Case Temp. (3 yr. warranty)
Standard Ambient Applications: 70°C Max. Case Temp. (5 yr. warranty)
FCC 47CFR Part 18 Non-Consumer
Class A Sound Rating
ANSI C62.41 Cat. A Transient Protection
Dynamic End-of-Lamp-Life Sensing
Remote Mounting up to 18 feet 5
4 Data based on PENTRON HO lamp types for primary ballast application.
5 Operation below 50°F may affect light output or lamp operation – see “Low
Temp. Starting” definition. Remote red and brown leads up to 18 feet. Keep
blue and yellow (for 4-lamp model only) leads <10 feet.
System Life / Warranty
QUICKTRONIC ® products are covered by our QUICK 60+ ® warranty, a compre- hensive lamp and ballast system warranty. For additional details, refer to our QUICK 60+ warranty bulletin.
Ordering Guide
Specifications subject to change without notice.
<10% THD Electronic T5 HO High Ambient Fluorescent Systems
- Also compatible with other manufacturer’s equivalent lamp types that meet ANSI standards.
- Rated lamp lumens and performance data based on PENTRON ® HO lamps.
- At 35°C lamp ambient temperature.
*(49135) QTP 2x54T5HO/UNV PSN HT: same as 49136, with leads.
**(49160) QTP 4x54T5HO/UNV PSN HTW: same as 49161, with leads.
Installation Notes
Switching: Simultaneously disconnect all ungrounded line conductors.
Install in accordance with National & Local Electric Code. Ground ballast
case.
Dimensions:
Model QTP2x54 T5HO/UNV PSN HT enclosure size:
Overall: 16.73″L x 1.18″W x 1.0″H (425mm L x 30mm W x 25.4mm H)
Mounting: 16.34″ (415mm)
Wiring:
Push-in connectors (no leads provided)
Use 18AWG solid copper wire only
See page 44 for wiring diagram.
Packaging:
Quantity: 20 (2-lamp)
Weight: 2L: 0.88 lbs each (approx)
Dimensions:
Model QTP4x54 T5HO/UNV PSN HT W enclosure size:
Overall: 16.73″L x 2.32″W x 1.0″H (425mm L x 59mm W x 25.4mm H)
Mounting: 16.34″ (415mm)
Wiring:
Push-in connectors (no leads provided)
Use 18AWG solid copper wire only
See page 45 for wiring diagram.
Packaging:
Quantity: 2-Lamp: 20 (no leads)
10 (with leads)
4-Lamp: 10 (leaded and non-leaded)
Weight : 2L: 0.88 lbs, 0.40kg each (approx)
4L: 1.68 lbs, 0.76kg each (approx)
2 LAMP T5HO UNV HT Fixed Output Ballast
<10% THD Electronic 2 Lamp T5HO High Ambient Fluorescent Systems
Lamp/Ballast Guide
Installation Notes
- Install in accordance with National & Local Electric Code
- Ground ballast case
- Switching: Simultaneously disconnect all ungrounded line conductors
Specifications
Refer to the last page of this Product Information Bulletin for full detail specifications.
New high ambient model (90°C case temp.)
49136 QTP 2x54T5HO/UNV PSN HT
Wiring diagram for 2-Lamp model
2-Lamp model can be wired for one lamp operation.
4 LAMP T5HO UNV HT Switchable Ballast
Installation Notes
- Install in accordance with National & Local Electric Code
- Ground ballast case
- Switching: Simultaneously disconnect all ungrounded line conductors
- The AC line inputs must be connected to the same phase of the line voltage
- DO NOT CONNECT two separate phases of line voltage to the input of the ballast
Input wiring for non-switching operation (Install jumper between black & red switching line terminals)
Input wiring for occupancy sensors (Install occupancy sensor/switch between black & red line terminals)
<10% THD Electronic 4 Lamp T5HO High Ambient Fluorescent Systems
4-Lamp Switching Wiring Diagram (4L to 2L)
S1 (Output A) | S2 (Output B) | Lamp Control |
---|---|---|
Closed (ON) | Closed (ON) | All 4 Lamps ON (Output A&B ON) |
Closed (ON) | Open (OFF) | 2 Lamps ON (Output A ON) |
Open (OFF) | Closed (ON) | 2 Lamps ON (Output B ON) |
Open (OFF) | Open (OFF) | All Lamps OFF |
New high ambient switchable model (90°C case temp.)
49161 QTP 4x54T5HO/UNV PSN HT W
3-Lamp Switching Wiring Diagram (3L to 2L, 3L to 1L)
S1 (Output A) | S2 (Output B) | Lamp Control |
---|---|---|
Closed (ON) | Closed (ON) | All 3 Lamps ON (Output A&B ON) |
Closed (ON) | Open (OFF) | 2 Lamps ON (Output A ON) |
Open (OFF) | Closed (ON) | 1 Lamp ON (Output B ON) |
Open (OFF) | Open (OFF) | All Lamps OFF |
2-Lamp Switching Wiring Diagram (2L to 1L)
S1 (Output A) | S2 (Output B) | Lamp Control |
---|---|---|
Closed (ON) | Closed (ON) | 2 Lamps ON (Output A&B ON) |
Closed (ON) | Open (OFF) | 1 Lamp ON (Output A ON) |
Open (OFF) | Closed (ON) | 1 Lamp ON (Output B ON) |
Open (OFF) | Open (OFF) | All Lamps OFF |
OSRAM SYLVANIA National Customer Service and Sales Center
1-800-LIGHTBULB (1-800-544-4828)
www.sylvania.com
The system solution®
Documents / Resources
|
SYLVANIA 49136 T5HO Fluorescent
Lamps
[pdf] Owner's Manual
49136 T5HO Fluorescent Lamps, 49136, T5HO Fluorescent Lamps, Fluorescent
Lamps, Lamps
---|---
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>