PROLiGHTS 60W RGBW-FC EclGallery Profile FC User Manual

October 31, 2023
PROLIGHTS

EclGalleryProfile FC
60W RGBW/FC zoomable LED ellipsoidals
with framing shutter

60W RGBW-FC EclGallery Profile FC

USER MANUAL

All rights reserved by Music & Lights S.r.l. No part of this instruction manual may be reproduced in any form or by any means for any commercial use.
In order to improve the quality of products, Music&Lights S.r.l. reserves the right to modify the characteristics stated in this instruction manual at any time and without prior notice.
All revisions and updates are available in the ‘manuals’ section on site www.musiclights.it

WARNING! Before carrying out any operations with the unit, carefully read this instruction manual and keep it with cure for future reference. It contains important information about the installation, usage and maintenance of the unit.

SAFETY

General instruction

  • The products referred to in this manual conform to the European Community Directives and are therefore marked with

  • The unit is supplied with hazardous network voltage (230V~). Leave servicing to skilled personnel only.
    Never make any modifications on the unit not described in this instruction manual, otherwise you will risk an electric shock.

  • Connection must be made to a power supply system fitted with efficient earthing (Class I appliance according to standard EN 60598-1).
    It is, moreover, recommended to protect the supply lines of the units from indirect contact and/or shorting to earth by using appropriately sized residual current devices.

  • The connection to the main network of electric distribution must be carried out by a qualified electrical installer. Check that the main frequency and voltage correspond to those for which the unit is designed as given on the electrical data label.

  • This unit is not for home use, only professional applications.

  • Never use the fixture under the following conditions:
    – in places subject to vibrations or bumps;
    – in places with a temperature of over 45 °C.

  • Make certain that no inflammable liquids, water or metal objects enter the fixture.

  • Do not dismantle or modify the fixture.

  • All work must always be carried out by qualified technical personnel. Contact the nearest sales point for an inspection or contact the manufacturer directly.

  • **** If the unit is to be put out of operation definitively, take it to a local recycling plant for a disposal which is not harmful to the environment.

Warnings  and installation precautions

  • If this device will be operated in any way different to the one described in this manual, it may suffer damage and the guarantee becomes void. Furthermore, any other operation may lead to dangers like short circuit, burns, electric shock, etc.
  • Before starting any maintenance work or cleaning the projector, cut off power from the main supply.
  • Always additionally secure the projector with the safety rope. When carrying out any work, always comply scrupulously with all the regulations (particularly regarding safety) currently in force in the country in which the fixture’s being used.
  • Install the fixture in a well ventilated place.
  • Keep any inflammable material at a safe distance from the fixture.
  • Shields, lenses or ultraviolet screens shall be changed if they have become damaged to such an extent that their effectiveness is impaired.
  • The lamp (LED) shall be changed if it has become damaged or thermally deformed.
  • Never look directly at the light beam. Please note that fast changes in lighting, e. g. flashing light, may trigger epileptic seizures in photosensitive persons or persons with epilepsy.
  • Do not touch the product’s housing when operating because it may be very hot.
  • This product was designed and built strictly for the use indicated in this documentation. Any other use, not expressly indicated here, could compromise the good condition/operation of the product and/or be a source of danger.
  • We decline any liability deriving from improper use of the product.

 INTRODUCTION

1.1 GALLERYECLFC – DESCRIPTION AND TECHNICAL SPECIFICATIONS
GALLERY ECL is a compact LED ellipsoidal luminaire designed for gallery, product, and shop window ligh
ing. Featuring a beautiful controllable beam, and stunning aesthetics, the GALLERY ECL is a flexible tfor commercial and product lighting.
LIGHT SOURCE

  • Source: 60W custom RGBW LEDs
  • Luminous Flux: (19°) 458 lm (36°) 570lm
  •  Lux: (19°) 570lux @3m Full
  • Lux: (36°) 166lux @3m Full
  • Source Life Expectancy: >30.000 h

OPTICS

  • Zoom:19°~36 ° Manual

  • Lens Type: HQ glass lens optics

  • Focus: Manual
    COLOR SYSTEM

  • Color Mixing: RGBW/FC

DYNAMIC EFFECTS

  • Static Color Mode: Selection of static color
  • Manual Color Mode: Manual adjustment of color
  • Auto Mode: Built-in programs with execution speed adjustment

BODY

  • Body: Sturdy die-cast aluminium body conceived for long-time durability
  • Body Color: Black

CONTROL

  • Protocols: WDMX
  • Dmx Channels: 4-6-11 ch
  • W-DMX: Included, Wireless Solution receiver
  • Display: Black OLED high resolution display

ELECTRONICS

  • Dimmer: Linear 0~100% electronic dimmer
  • Dimmer Curves:4 Different dimming curves available
  • Strobe/Shutter:1-30 Hz, electronic
  • Operating Temperature: -10° ~ +45°
  • Flicker: Flicker free operation

ELECTRICAL

  • Power Supply: 100-240V – 50/60Hz
  • Power Consumption (at 230V):43,5 W
  • Power Consumption (at 120V):43,8 W

PHYSICAL

  • Power Connection: 16A Shuko plug
  • IP: 30
  • Cooling: Natural cooling of the peculiar chassis and to absence of fans
  • Dimensions (WxHxD): 183x230x338mm
  • Weight: 2.9kg

PROLiGHTS 60W RGBW-FC EclGallery Profile FC -
GALLERYECLFC

1.2 OPERATING ELEMENTS AND CONNECTIONS

PROLiGHTS 60W RGBW-FC EclGallery Profile FC -
CONNECTIONS

  1.  GALLERYECLFC
  2. LOCKING KNOB for optics profiler
  3. SAFETY EYE to attach safety cable.
  4.  ROTARY ARM
  5.  CONTROL PANEL with display and 4 buttons used to access the control panel functions and manage them
  6. GALLERYECLFC optics profiler
  7. FOCUS AND ZOOM ADJUSTING SCREW to zoom the projected image clearly
  8. SHUTTER
  9. FIXING TILT

 INSTALLATION

2.1 MOUNTING
GALLERYECLFC is designed for applications in exhibition areas, commercial spaces, museums, restaurant, churches, and any other installation where size is an important factor. For fixing, stable mounting clips are required. The mounting place must be of sufficient stability and be able to support a weight of 10 times of the unit’s weight.
When carrying out any installation, always comply scrupulously with all the regulations (particularly regarding safety) currently in force in the country in which the fixture’s being used.

  • Install the projector at a suitable location.
  • Always additionally secure the projector with the safety rope from falling down. For this purpose, fasten the safety rope at a suitable position so that the maximum fall of the projector will be 20 cm. The adjust the projector and use the knobs.

NOTE – For the installation of the GALLERYECLDY make sure that the ridge of the adaptor is in with the groove of the track. Turn knobs 90° to connect the adaptor to the circuit. Please see the figure 4.PROLiGHTS 60W RGBW-FC
EclGallery Profile FC - adaptor

FUNCTIONS AND SETTINGS

3.1 OPERATION
To turn on the GALLERYECLFC connect the supplied main cable to a socket (100-240 VAC-50/60 Hz). Then the unit is ready for operation. You can also adjust the dimmer and zoom using the knobs.
To switch off, disconnect the mains plug from the socket. For a more convenient operation it is recommended to connect the unit to a socket which can be switched on and off via a light switch.
NOTE – To operate the projector GALLERYECL you need a system track. The track system must be installed and maintained by a suitably qualified person in compliance with latest construction and relevant legislation. It is the responsibility of the installer to ensure the electrical, mechanical and thermal compatibility of the track system and the fittings. The connection to the main network of electric distribution must be carried out by a qualified electrical installer.
ATTENTION – Mains voltage must be switched off before mounting; maintenance; insert and replace Adaptors; spots and luminaires.
3.2 BASIC
Access control panel functions using the four panel buttons located directly underneath the LED Display (fig.5).PROLiGHTS 60W RGBW-FC EclGallery Profile
FC - buttons

MENU UP DOWN ENTER
Used to access the menu or to return a  revious menu option Navigates

downwards through the menu list and increases the numeric value when in a function| Navigates upwards through the menu list and decreases the numeric value when in a function| Used to select and store the current menu or confirm the current function value or
option within a menu

3.3 MENU STRUCTURE

MENU| | | | | |
---|---|---|---|---|---|---
CONNECT| | DMX Address| 14>| Value (001-512)| |
| DMX Mode|
| 4G1 601 11th| |
| Wireless| | Reek On/Off Receiw Reset| |
SOW|
| Screen| | Back Light
flip Display Key Lock| 1m.
r
| On
105 205 305 NO-Yes
NO-Yes
ADVANCED| | Dormer Mode| .–| Off
Dimmed Dimme1
Dimmer 2
Dimmer 3| |
| White Balance| 1
| Off Adjust| 1| Red <125-255> Green <125-255> Blue <125-255> White <125-255>
| Led Frequency|
| 6004tr
1200 Hz 2000 Hz 4000 Hz 60001t 25E112| |
| Reset Factory| | NO-Yes| |
INFORMATION|
| Fixture Hours Temperature Version|
c>
| 0-9999
58’C
V1.0| |
STANDALONE| 1| Master/Slave| 1>| Master/Slave| |
| Effects|
| Show I Show 2 Show 3 Show 4 Show 5| | Speed 1-100
| Static
Fixed Color
ð R
RW
G
GW
B
BW
W
RGW
GB
RBW
RB
GBW
RG
RGBW
RGB
Color Temperature
ð 3000K
4000K
5000K
6000K
7000K
8000K
9000K
10000K
Manual Color
ð Red
<0-255>
Green
<0-255>
Blue
<0-255>
White
<0-255>
---|---

3.4 DMX MODE

  • Press the button MENU so many times until the display shows DMX ADDRESS, and press the button ENTER to confirm.
  • Press UP/DOWN button to select the desired value (001-512). Press and hold to scroll quickly.
  • Press ENTER button to store.
  • Press the MENU button to go back or to meet the waiting time to exit the setup menu.

To able to operate the GALLERYECLFC/TRWD with a light controller, adjust the DMX start address for the first a DMX channel. If e. g. address 33 on the controller is provided for controlling the function of the first DMX channel, adjust the start address 33 on the GALLERYECLFC/TRWD. The other functions of the light effect panel are then automatically assigned to the following addresses.
An example with the start address 33 is shown below:
3.5 DMX CONFIGURATION
GALLERYECLFC/TRWD is equipped with different DMX configuration.

  • Press the button MENU so many times until shows DMX CHANNEL, and press the button ENTER to confirm.
  • Select the desired DMX configuration (4CH – 6CH – 11CH ) through the buttons UP/DOWN.

The tables on page 14 indicate the operating mode and DMX value.
3.6 WIRELESS SETTING
To set the wireless mode refer to the following guide:

  • Press the MENU button until the display shows Wireless Setting, then press the ENTER button.
  • Use the UP/DOWN button until the display reads Wireless Receive, and then press the ENTER button and select the ON mode.
  • Press the MENU button to go back or to meet the waiting time to exit the setup menu.

NOTE – After you complete these steps, you have to synchronize with any wifi unit with which you want to communicate by pressing the sync button present on the same. Then connect any DMX console to wifi unit for to open the communication with the GALLERYECLFC/TRWD unit.

  • To reset the unit press the MENU button until the display shows Wireless Reset, then press the ENTER button.
  • Use the UP/DOWN button until the display reads Yes, and then press the ENTER button.

Press the MENU button to go back or to meet the waiting time to exit the setup menu.

Number of DMX channels| Start address (example)| DMX Address occupied| Next possible start address for unit No. 1| Next possible start address for unit No. 2| Next possible start address for unit No. 3
---|---|---|---|---|---
11| 33| 33-43| 44| 55| 65

PROLiGHTS 60W RGBW-FC EclGallery Profile FC - channels

3.7 CHANNELS DMX
4 CANALI

MODE 4 Ch FUNCTION DMX Value
1 RED 0-100% 255
2 GREEN 0-100% 000 -255
3 BLUE 0-100% 000-255
4 WHITE 0-100% 000-255

6 CANALI

MODE 6 Ch FUNCTION DMX Value
1 DIMMER 0-100% 000-255
2 RED 0-100% 000-255
3 GREEN 0-100% 000-255
4 BLUE 0-100% 000-255
5 WHITE 0-100% 000-255
6 STROBE NO Function Strobe Slow to Fast 000-010  011-255

11 CANALI

MODE 11 Ch FUNCTION DMX Value
1 DIMMER 0-100% 000 – 255
2 RED 000 – 255
3 GREEN
0–100% 000 – 255
4 BLUE
0-100% 000 – 255
5 WHITE
0-100% 000 – 255
6 STROBE 000 – 010

11 CANALI

MODE 11 Ch FUNCTION DMX Value
7 OLOR MACRO

No Function
R 100%,
G 0~100%,
B 0%
R 100%~0%,
G 100%,
B 0%
R 0%,
G 100%,
B 0~100%
R 0%
G 100%~0%
B 100%
R 0%~100%
G 0%
B 100%
R 100%
G 0%  B
100%~0%
R 100%
G 0%~100%
B 0%~100%
R 100%~0%
G 100%~0%
B 100%
R 100%
G 100%
B 100%
Color1
Color2
Color3
Color4
Color5
Color6
Color7
Color8
Color9
Color10
Color11| 000 – 010
011 – 030
031 – 050
051 – 070
071 – 090
091 – 110
111 – 130
131 – 150
151 – 170
171 – 200
201 – 205
206 – 210
211 – 215
216 – 220
221 – 225
226 – 230
231 – 235
236 – 240
241 – 245
246 – 250
251 – 255
8| COLOR TEMPERATURE
NO function
3000k
4000k
5000k
6000k
7000k
8000k
9000k
10000k
NO function|  000 – 005
006 – 039
040 – 069
070 – 099
100 – 129
130 – 159
160 – 189
190 – 219
220 – 250
251 – 255
9| AUTO PROGRAMS
No Function
Auto Program 1
Auto Program 2
Auto Program 3
Auto Program 4
Auto Program 5(Auto Program1- 4)| 000 – 010
011 – 060
061 – 110
111 – 160
161 – 210
211 – 255
10| AUTO SPEED Auto speed slow to fast| 000 – 255
11| DIMMER SPEED MODE
Preset dimmer speed from display menu
Dimmer speed mode off
Dimmer speed mode1 (fast speed)
Dimmer speed mode2 (middle speed)
Dimmer speed mode3 (slow speed)| 000 – 051
052 – 101
102 – 152
153 – 203
204 – 255

3.8 SETTINGS
You can change the parameters for the device by following these steps:
SCREEN
You can change the following parameters related to the display, following the same procedure:

  • Press the ENTER button to access the main menu.

  • Press the UP / DOWN keys to scroll the menu, select the Set Up icon, then press the ENTER button to enter the next menu.

  • Press UP / DOWN to scroll through the menu, then select Screen, and press the ENTER button to enter the next menu.

  • Press UP / DOWN to scroll through the menu, and then select one of the following settings for the display and press the ENTER key to display it.
    – Back Light – Backlight display Auto Off. This feature allows you to automatically turn off the backlight after a specified time that you can set using the arrow buttons. To have the display always on select Always On or choose another value to turn off the display after the amount of time you choose.
    – Flip Display – Orientation of the display. This function allows you to rotate the display 180° to get a better view of the display when the unit is hanging upside down. Select YES to activate or NO to disable this function.
    – Key Lock – Lock keys. With this function, you can lock the buttons on the control panel. If this function is activated, the keys are automatically locked. To disable or temporarily disable the key lock function, press the buttons in the following order to regain access to menu commands:
    UP, DOWN,UP, DOWN, ENTER. Select YES to activate or NO to disable.

  • Press the ENTER button to confirm your choice.

  • Press the LEFT button repeatedly to exit the menu and save changes.

3. 9 FIXTURE SETTINGS
It is possible to change the parameter value in the following way:
DIMMER

  • Enter in Dimmer mode to select specific dimming curve, press the button MENU so many times until shows DIM MODE, and press the button ENTER to confirm.
  • Press the button UP/DOWN to select OFF – DIM1 – DIM2 – DIM3.
  • Press ENTER button to store.
  • Press the MENU button to go back or to meet the waiting time to exit the setup menu.

WHITE CALIBRATION

  • Press the button MENU then press the button UP/DOWN so many times until show WHITE CALIBRATION. Press the button ENTER to confirm.
  • Select the color Red – Green – Blue – White through the buttons UP/DOWN. Press the button ENTER to confirm.
  • Set the value (125 – 255), using the buttons UP/DOWN.
  • Continue until the desired setting is obtained.
  • Press the MENU button to go back or to meet the waiting time to exit the setup menu.

LED FREQUENCY

  •  To adjust the frequency of the LEDs, press the MENU button repeatedly until the display shows LED Frequency, and then press the ENTER button.
  • Select the frequency (600Hz – 1200Hz – 2000Hz – 4000Hz – 6000Hz – 25kHz) using the UP/DOWN buttons.
  • To confirm, press the ENTER key.
  • Press the MENU button to go back or wait a few seconds to exit the setup menu.

RESET FACTORY

  • To activate RESET FACTORY display press the button MENU so many times until shows RESET FACTORY, and press the button ENTER to confirm.
  • Press ENTER button to confirm the selection.
  • Press the MENU button to go back or to meet the waiting time to exit from the setup menu automatically.

3. 10 FIXTURE INFORMATION
To view all the information on the device, proceed as follows:

  • Press the ENTER button to access the main menu.

  • Press the UP/DOWN button to scroll the menu, select the icon Information, then press the ENTER button to enter the next menu.

  • Press the UP/DOWN button to scroll through the menu, then select one of the following information and press the ENTER button to display it.
    – Fixture Time – Through the Fixture Time function you can display the operating time of the projector.
    – Temperature – Through the Temperature function can be displayed the temperature inside the fixture, near the lamp. The temperature can be displayed in degrees Celsius or Fahrenheit.
    – Software Version – Through Software Version function you can display the currently installed software version.

  • Press the LEFT button repeatedly to exit the menu.

3. 11 OPERATIONS IN AUTOMATIC MODE
MASTER SLAVE
Press the UP/DOWN button to scroll through the menu, select Master/Slave and press ENTER to confirm your choice.

  • Press the UP/DOWN button to select the mode of operation:
    – Master, if the unit is connected in series with other units and it acts as the Master;
    – Slave, if the unit is not connected to other units.

  • Press the ENTER button to confirm your choice.

EFFECTS
The unit independently runs through its show. Before you send an automatic program you need to set the drive as Master/Alone:

  • Press the ENTER button to access the main menu.

  • Press the UP/DOWN button to scroll the menu, select the Effects icon, then press the ENTER button to enter the next menu.

  • Press the UP/DOWN button to select the mode of operation: Effects 1, Effects 2, Effects 3, Effects 4, Effects 5

  • Press the ENTER button to confirm your choice.

  • Press the LEFT button repeatedly to exit the menu and save changes.
    The unit will go into automatic mode by executing the program automatically.
    STATIC MODE This fixture has the ability to accept custom static color settings. Access these chases via the control panel on the back of the fixture.

  • Press the button MENU so many times until the display shows STATIC, then press the button ENTER.

  • Select Fixed Color through the buttons UP/DOWN, then press the button ENTER.

  • Set the colors R, G, B, W, GB, RB, RG, RGB, RW, GW, BW, RGW, RBW, GBW, RGBW, through the buttons UP/DOWN, then press the button ENTER.

  • Press the MENU button to go back or to meet the waiting time to exit the setup menu.

  • Select Color Temperature through the buttons UP/DOWN, then press the button ENTER.

  • Set the colors temperatur: 3000K, 4000K, 5000K, 6000K, 7000K, 8000K, 9000K, 10000K, through the buttons UP/ DOWN, then press the button ENTER.

  • Press the MENU button to go back or to meet the waiting time to exit the setup menu.

  • Select Manual Color Mixer through the buttons UP/DOWN, then press the button ENTER.

  • Set the colors Red, Green, Blue, White, through the buttons UP/DOWN, then press the button ENTER.

  • Press the MENU button to go back or to meet the waiting time to exit the setup menu.

MAINTENANCE

4.1 MAINTENANCE AND CLEANING THE UNIT

  • Make sure the area below the installation place is free from unwanted persons during setup.
  • Switch off the unit, unplug the main cable and wait until the unit has cooled down.
  • All screws used for installing the device and any of its parts should be tightly fastened and should not be corroded.
  • Housings, fixations and installation spots (ceiling, trusses, suspensions) should be totally free from any deformation.
  • The main cables must be in impeccable condition and should be replaced immediately even when a small problem is detected.
  • It is recommended to clean the front at regular intervals, from impurities caused by dust, smoke, or other particles to ensure that the light is radiated at maximum brightness. For cleaning, disconnect the main plug from the socket. Use a soft, clean cloth moistened with a mild detergent. Then carefully wipe the part dry. For cleaning other housing parts use only a soft, clean cloth. Never use a liquid, it might penetrate the unit and cause damage to it.

4.2 TROUBLESHOOTING

Problems Possible causes Checks and remedies
Fixture does not light up • No mains supply

• Dimmer fader set to 0
• Faulty LED| • Check the power supply voltage
• Increase the value of the dimmer channels
• Replace the LED board
General low light intensity| • Dirty lens assembly
• Misaligned lens assembly| • Clean the fixture regularly
• Install lens assembly properly
Fixture does not power up| • No power
• Loose or damaged power cord| • Check for power on power outlet
• Check power cord

Contact an authorized service center in case of technical problems or not reported in the table can not be resolved by the procedure given in the table.
MUSIC & LIGHTS S.r.l. – Phone +39 0771 72190 – www.musiclights.it

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Related Manuals