TESY AC16EHCI Air Purifier/Cleaner Instructions

June 6, 2024
TESY

**TESY AC16EHCI Air Purifier/Cleaner Instructions

**

IMPORTANT SAFETY INSTRUCTIONS

WARNING!

When using electrical appliances, basic precautions should always be followed to reduce breakage, risk of fire, electric shock and injury to persons including the following:

  • Please read this manual before using this product and save it for future reference. In case that the product is acquired by a new owner he/she must get this manual.

  • Children under 3 years of age should be kept away from the appliance unless they are under constant supervision.
    Children from 3 to 8 years of age are allowed to operate the on/off button ONLY, provided that the appliance is installed and ready for operation and such children have been supervised and instructed in safe operation of the appliance and they understand all related risks.
    Children from 3 to 8 years of age MUST NOT: connect the plug to power sockets, make adjustments, clean it or carry out user maintenance operations.

  • This appliance can be used by children older than 8 years of age and by people with reduced physical, sensor and mental capabilities, as well as by people with insufficient experience and knowledge provided they are supervised or instructed in safe operation of the appliance and understand the related risks. Children should not be allowed to play with the appliance.
    Cleaning and user maintenance operations must not be carried out by children without supervision.

  • Read all instructions before operating the air cleaner.

  • Place the air cleaner where it is not possible to be easily knocked over by persons in the household.

  • ALWAYS unplug air cleaner when not in use.

  • DO NOT use any product with a damaged cord or plug, or if product malfunctions, is dropped or damaged in any manner.
    If the power cord is damaged, it must be replaced by the manufacturer, its service agent or similar qualified persons in order to avoid hazard to the user.

  • Keep the power cord away from heated surfaces.

  • Do not use the air cleaner outdoors.

  • Never use the air cleaner unless it is fully assembled.

  • Do not run power cord under carpets and DO NOT COVER with throw rugs. Arrange cord so it will not be tripped over.

  • Do not use air cleaner where combustible gases or vapors are present.

  • Do not expose the air cleaner to rain, or use near water, in a bathroom, laundry area or other damp locations.

  • To disconnect the air cleaner, press the button to turn off and remove plug from outlet.

  • Do not allow foreign objects to enter ventilation or exhaust opening, as this may cause electric shock or damage to the air cleaner.

  • Place the air cleaner near a power outlet, and avoid using an extension cord.

  • A loose fit between the plug and the AC outlet (receptacle) may cause overheating and distortion of the plug. Contact a qualified electrician to replace loose or worn receptacles.

  • Do not sit, stand or place heavy objects on the air cleaner.

  • Always disconnect power supply before servicing.

  • In order to reduce risk of fire or electric shock – DO   NOT use this product with a revolutions control device.

INTRODUCTION

Congratulations on your choice of TESY Air Cleaner.

We highly recommend that you operate the Air Cleaner 24 hours a day, because indoor air can be quickly contaminated by activity or objects in a room and infiltration of outside air. Portable air cleaners are much more effective in rooms where all doors and windows are closed.

The appliance will give you long-lasting service if operated and taken care of correctly in accordance with these instructions.

HOW IT WORKS

Air to be cleaned enters through specially designed openings on the front panel and goes out at the back upper part of the appliance through the fan protection cover. Protection cover is designed with a peculiar shape in order to reduce noise emissions of the appliance. That allows you to use your Air cleaner all the time – 24 hours a day and even in your bedroom.

Note: Keep air inlet and outlet openings clear from any objects: objects should be away at least 1.5m in front and 1.5m above the appliance.
HOW IT WORKS

  1. Pre-filter – Pre-filter made of active carbon
  2. HEPA filter – HEPA filter
  3. VOC filter – filter with granulated active carbon
  4. TiO2 mesh – Photocatalytic filter
  5. UV lamps – Ultra-violet lamps
  6. Ionizer – Ionizer

Pre-filter: The pre-filter is made from active carbon and is intended to absorb smell from cooking ant pets as well as tobacco smoke. It also retains bigger dust particles, fluff or pets’ fur hairs.

HEPA filter: The function of the HEPA filter is to absorb particles – dust, pollen, fungi spores and different kinds of bacteria. HEPA filter can not absorb particles smaller than 0.3 micron – such as chemical evaporations, gases, some tobacco smoke particles, germs and viruses. HEPA filter efficiency is up to 99.97%

VOC: filter with granulated active carbon has a very good absorbing capacity to smells, gases and tobacco smoke.

TiO2: The photocatalytic filter reduces organic pollutants– benzol and ammonia. It also desactivates bacteria and viruses which pass through previous filters and which are not absorbed because of their size.

UV lamps: The ultra-violet lamps destroy effectively microorganism cells including microbes, viruses, bacteria and fungi which are nor absorbed by previous filters because of their size

Ionizer: The ionizer disperses negative ions in the room in order to enhance cleaning process and at the same time it freshens up air. Negative ions combine with dust particles in the air and fall to the floor because of their own weight (dust and ions that have combined with it). Room floor is necessary to be cleaned on a regular basis.

OPERATION

Note: NEVER operate the Air Cleaner without the HEPA filter properly installed. This could lead to permanent motor and appliance damage.

Advice: Each time you start the Air Cleaner, it is a good idea to run it at H speed for a few seconds for fast, initial cleaning. Then set to M (medium), L (low) or leave at H (high) as desired.
OPERATION

This Air Cleaner is equipped with an active carbon Prefilter, HEPA Filter, granulated active carbon filter, Photo catalytic filter, UV lamps and Ionizer.

INITIAL START-UP

  1. Take the Air Cleaner out of its packing.

  2. Remove the protection polyethylene envelope above the granulated active carbon filter (VOC).

  3. Ensure that the filters are arranged correctly and check if all of them are positioned in their place (in accordance with the filters diagram above).

  4. Connect the power cord to an electricity outlet in a correct manner (Before switching on the appliance ensure that the technical plate voltage concurs with the voltage in your electricity system).

  5. Press the power button to turn the air cleaner on.
    Press the same button again to turn the air cleaner off.

  6. Press the fan button to select the fan speed: L (Low) > M (Medium) > H (High)

  7. Press the clock button to select the timer-off function: 1 > 2 > 4
    The timer-off can be set to 1 – 7 hours. The air cleaner will automatically turn off after it has been in operation for the selected hours.

  8. Press the ion button to turn on the ionizer function.
    Press the button again to turn this function off.

  9. Press the UV button to turn on the UV function.
    Press the button again to turn this function off.

  10. The filter indicators will light up when the filters need to be replaced. After the necessary replacement of filters hold the filter button for several seconds until the filter indicator shuts off. This will reset the hours of filters use timer.

FILTER REPLACEMENT SCHEDULE

The usable lifetime of the active carbon pre-filter is 1400 hours and usable life time of the HEPA and the VOC Filter is 2800 hours, depending on the level of the room’s air contaminants and the frequency of use.

Note: The volume of air to be cleaned will decrease considerably when the filters need to be replaced.

We recommend having at hand a spare set of filters for future replacement and depending on the filter replacement light indication to replace the filter and restart the timer of the filter that has been replaced.

Note: Photo catalytic TiO2 filter is not to be replaced.

When a special need occurs to buy a new filter it is necessary to contact the Service Headquarters in your region and request a delivery of this filter.

FILTER REPLACEMENT

Filters are specially designed for easy replacement and to provide maximum performance.

  1. When the ‘replace filter’ light is illuminated, you should switch the air cleaner off and disconnect the power cord from the electricity socket.

  2. Take the air cleaner and place it on a flat surface with the appliance in horizontal position.

  3. Place one hand on the middle top of the cover, insert your finger in the slot at the side of the air cleaner and pull the front cover outwards.

  4. Remove and discard used filter/s in a specially designated location in your neighborhood.

  5. Remove any plastic protective wrapping and packaging from the new filter/s.

  6. Put the new filter/s into the air cleaner (in accordance with the filter diagram above).

  7. Install the Front Grille by engaging its tabs into the bottom slots on the unit. Then swing the grille up and gently press on the top to snap into place.
    Note: Ensure that the filters are arranged correctly and check if all the filters are in their place before connecting the power plug to the socket.

  8. Plug the air cleaner into an outlet for operation.

  9. After replacing the filter/s push and hold button for 3 seconds to reset the filters use timer.
    Note: HEPA and VOC filters are to be replaced at the same time when the filter check light illuminates!
    FILTER REPLACEMENT

CLEANING THE UNIT

Note: To avoid serious injury from electric shock ALWAYS turn the Air Cleaner OFF and disconnect the plug from the outlet BEFORE cleaning.

  1. Turn the Air Cleaner Off and unplug from the outlet.
  2. Clean the unit with a moistened soft cloth only. Do not pour or splash water on the unit or use any abrasive-type cleaner on it. Clean all external surfaces, especially the air intake grilles and the air outlet.
  3. Do not attempt to clean the filters (except Photo catalytic TiO2 filter, which should be cleaned with a soft brush at every replacement of HEPA and VOC filters)
  4. Filters are not washable and washing will damage them and the air cleaner.
  5. Reposition the Air Cleaner plug into the power outlet and turn on the appliance.

STORAGE

If you shall not use your Air Cleaner for some time you should do the following:

  1. Remove the filters from the unit.
  2. Wrap the filters in an air-tight plastic bag or plastic wrap. Be sure that the filters are totally sealed to protect them from their storage environment.
  3. Do not put the plastic-wrapped filters back into the Air Cleaner.
  4. Use the air cleaner original packing to store it if the appliance shall not be used for a period of time. That way the appliance is protected from excessive dust and durt accumulation.
  5. The appliance should be stored in a dry and protected from direct sun light place.
  6. It is strongly prohibited to store the appliance in damp or wet places.
  7. To restore the Air Cleaner to service:
    • Unwrap the filters
    • Install the filters assembly in the air cleaner according to diagram above. See “Filter Replacement” section for proper installation.

REPLACEMENT PARTS

“TESY” Air cleaners models AC16EHCI, AC29EHCI and AC37EHCI are provided with the following sets of filters, which are necessary for one year operation (2800 hours of Air cleaner operation):

  • 2 pre-filters
  • 1 HEPA filter
  • 1 VOC filter (granular carbon).

Note: You may request a replacement part for a particular model in the trade center – filters are not interchangeable for the different air cleaner models!

CUSTOMER ASSISTANCE LINE

DO NOT attempt to repair this unit yourself. Doing so will void your warranty, and could cause serious personal injury to yourself, or damage the Air Cleaner.

Environment protection instructions.

Old electrical appliances contain valuable materials and therefore should not be treated as domestic waste! We kindly ask you to cooperate us with your active contribution to resources and environment preservation by disposing the appliance to authorized waste-disposal locations (if there are any).

TESY logo

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals