Laserliner Gi4 Laser Range Finder Instruction Manual
- June 6, 2024
- Laserliner
Table of Contents
- Laserliner Gi4 Laser Range Finder Instruction Manual
- Laserliner Gi4 Laser Range Finder
- LaserRange-Master Gi4
- Function / Application
- General safety instructions
- Safety instructions
- Safety instructions
- Inserting batteries
- DISPLAY:
- KEYPAD:
- Switch on, measure and switch off:
- Change measurement point (reference):
- Change measurement function:
- Length measurement
- Area measurement:
- Volume measurement:
- Min.\Max. measurement
- Min. measurement
- Max. measurement
- Important notices
- Error codes:
- Information on maintenance and care
- Calibration
- EU directives and disposal
- Read More About This Manual & Download PDF:
- References
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
Laserliner Gi4 Laser Range Finder Instruction Manual
Laserliner Gi4 Laser Range Finder
LaserRange-Master Gi4
LaserRange-Master Gi4
Completely read through the operating instructions, the „Warranty and
Additional Information“ booklet as well as the latest information under the
internet link at the end of these instructions. Follow
the instructions they contain. This document must be kept in a safe place and
if the laser device is passed on, this document must be passed on with it.
Function / Application
Laser distance meter – with green laser technology
– Functions: distances, area, volume, min./max. measurement
General safety instructions
– The device must only be used in accordance with its intended purpose and
within the scope of the specifications.
– The following persons may use the device only when they are either
supervised by a person who is responsible for their safety or have received
instruction from this person on how to use the device:
– Persons with restricted physical, sensory or mental abilities
– Persons with no knowledge and/or experience in the use of the device
– Children (under the age of 14)
– The device and its accessories are not toys.
– Modifications or changes to the device are not permitted, this will
otherwise invalidate the approval and safety specifications.
– Do not expose the device to mechanical stress, extreme temperatures,
moisture or significant vibration.
– The device must no longer be used if one or more of its functions fail or
the battery charge is weak.
– Please ensure compliance with the safety regulations set out by local and
national authorities with regard to the correct and proper use of the device.
Safety instructions
Using class 2 lasers
– Attention: Do not look into the direct or reflected beam.
– Do not point the laser beam towards persons.
– If a person‘s eyes are exposed to class 2 laser radiation, they should shut
their eyes and immediately move away from the beam.
– Tampering with (making changes to) the laser device is not permitted.
– Under no circumstances should optical instruments (magnifying glass,
microscope, binoculars)
Safety instructions
Dealing with electromagnetic radiation
– The measuring device complies with electromagnetic compatibility regulations
and limit values in accordance with EMC-Directive 2014/30/EU.
– Local operating restrictions – for example, in hospitals, aircraft, petrol
stations or in the vicinity of people with pacemakers – may apply. Electronic
devices can potentially cause hazards or interference or be subject to hazards
or interference.
– The measuring accuracy may be affected when working close to high voltages
or high electromagnetic alternating fields.
Inserting batteries
Open the battery compartment and insert batteries (2 x typ AAA) according to the symbols. Be sure to pay attention to polarity.
DISPLAY:
a Measurement point (reference) rear / front
b Display length / area / volume
c Measurement values / Measurement results Unit m
d Intermediate values / min/max values
e Battery symbol
f Min./max. measurement
g Malfunction / service required
KEYPAD:
- ON / Measure / OFF
- Length, area, volume, min./max. measurement
Measurement point (reference) rear / front
Switch on, measure and switch off:
Change measurement point (reference):
Change measurement function:
Length measurement
Area measurement:
Volume measurement:
Min.\Max. measurement
Min. measurement
The LC display shows the lowest value (min.) and the current value.
Max. measurement
The LC display shows the highest value (max.) and the current value.
Important notices
- The laser points to the location that will be measured. No objects may get into the laser‘s line of measurement.
- The device compensates the measurement for different room temperatures. Therefore allow the device a brief adaptation period when changing locations with large temperature differences.
- The device is only conditionally useable in outdoor areas and cannot be used in strong sunlight.
- The measurement results of outdoor measurements may be influenced or falsified by rain, fog and snow.
- In unfavourable conditions, e.g. with poorly reflecting surfaces,
- the maximum deviation may be greater than 3 mm.
- Carpeting, upholstery or curtains will not reflect the laser optimally. Measure to flat surfaces.
- Measurements made through glass (window panes) can falsify measurement results.
- An energy-saving function switches the device off automatically.
- Clean with a soft cloth. Water may not be allowed to penetrate the housing.
Error codes:
Err08: Pythagorean measurement error
Err10: Replace the battery
Err11: Data transfer error
Err14: Calculation error
Err15: Outside the measuring range
Err16: Received signal too weak
Err26: Value outside display range
Information on maintenance and care
Clean all components with a damp cloth and do not use cleaning agents,
scouring agents and solvents. Remove the battery(ies) before storing for
longer periods. Store the device in a clean and dry place.
Calibration
The measuring device should be calibrated and tested on a regular basis to
ensure it is accurate and working properly. We recommend
the measuring device is calibrated every 1 – 2 years. If necessary, contact
your distributor or the UMAREX-LASERLINER service department.
Technical Data (Subject to technical changes without notice. 21W09)
Precision (typical)*| ± 2 mm
Measurement range (inside)**| 0.3 m – 40 m
Laser class| 2 / < 1 mW (EN 60825-1:2014/AC:2017)
Laser wavelength| 515 nm
Operating conditions
| -10°C … 40°C, max. humidity
20 … 85% rH, no condensation, max. working altitude 2000 m above sea level
Storage conditions| -20°C … 70°C,
max. humidity 80% rH
Automatic switch-off| 30 sec laser / 3 min device
Power supply| 2 x 1.5V LR03 (AAA)
Dimensions (W x H x D)| 40 x 110 x 24 mm
Weight (incl. batteries)| 90 g
- measuring distance up to 10 m with strongly reflective target surface and at room temperature. The measurement deviation may increase
by ± 0.2 mm/m for weakly reflective target surfaces.
** at max. 5000 lux
EU directives and disposal
This device complies with all necessary standards for the free movement of
goods within the EU.
This product is an electric device and must be collected separately for
disposal according to the European Directive on waste electrical and
electronic equipment.