KLEIN TOOLS 93LCLG Self-Leveling Green Cross Line Laser Level with Red Plumb Spot Instruction Manual

June 6, 2024
KLEIN TOOLS

KLEIN TOOLS 93LCLG Self-Leveling Green Cross Line Laser Level with Red

Plumb Spot

GENERAL SPECIFICATIONS

Klein Tools 93LCLG is a self-leveling laser alignment instrument that can be used to deliver horizontal and/or vertical cross lines, and/or plumb spots directly above/below the instrument, for alignment and layout applications.

  •   Operating Altitude: 6562 ft. (2000 m)

  •   Relative Humidity: <80% non-condensing

  •   Operating Temp: 20°F to 115°F (-10°C to 45°C)

  •   Storage Temp: -5°F to 140°F (-20°C to 60°C)

  • Lasers:
    515-530 nm (cross lines)
    630-680 nm (plumb spots)
    ≤1mW each beam, Class II Laser Product

  • Accuracy:
    ±3/32″ per 33′ (±2 mm per 10 m) Vertical & Horizontal Beams
    ±1/8″ per 33′ (±3 mm per 10 m) Plumb Up Spot
    ±5/32″ per 33′ (±4 mm per 10 m) Plumb Down Spot

  •   Battery Type: 3 x 1.5V AA Alkaline

  •   Dimensions: 5.3″ x 5.0″ x 2.8″ (134 x 127 x 65 mm)

  •   Weight: 26 oz. (820 g) without batteries

  •   Calibration: Accurate for one year

  • Standards:
    Conforms to: EN61326-1:2013, EN60825-1:2014.
    Complies with: 21 CFR 1040.10 and 1040.11 except for deviations  pursuant to laser notice No. 50, dated June 24, 2007.

  •   Ingress Protection: IP54 Dust & Water Resistant

  •   Electromagnetic Environment: IEC EN61326-1:2013. This equipment meets requirements for use in basic and controlled electromagnetic environments like residential properties, business premises, and light-industrial locations.

Specifications subject to change.

WARNINGS

To ensure safe operation and service of the instrument, follow these instructions. Failure to observe these warnings can result in serious personal injury, fi re, or electrical shock. Retain these instructions for future reference.
WARNING: LASER RADIATION. DO NOT STARE INTO BEAM. Class II Laser.

KLEIN TOOLS 93LCLG Self-Leveling Green Cross Line Laser Level with Red Plumb
Spot fig 1

  • Exposing eyes to laser radiation can result in severe and permanent eye injuries. NEVER look directly into the laser beam emitted by this instrument.
  •  Do not use the instrument if it appears to be damaged.
  •  Do not modify the instrument in any way, as to do so could result in emission of hazardous laser radiation than could result in severe eye injuries .
  •  Do not use optical equipment such as lenses, prisms, optical scopes, etc. to transmit, retransmit, or view the laser beam as this could result in severe eye injuries.
  •  This product should not be used by untrained operators or operators who have not read and fully understood the instructions.
  •  This product should not be used in any location that could result in somebody looking at or having their eyes inadvertently irradiated by the laser beam as this could result in severe eye injuries.
  •  The instrument should be powered off following use to minimize the risks of inadvertently exposure to hazardous laser radiation that could result in severe eye injuries.
  • Do not remove warning labels from this instrument as this could result in serious personal injury and increases the risk of exposure to hazardous laser irradiation.
  •  The instrument should be securely located in a tidy work environment prior to operation as unexpected drops or movement of the instrument may result in damage to the instrument and increases the risk of inadvertent exposure to laser radiation that could result in severe eye injuries.
  •  This instrument is IP54 dust & water resistant. Following any contact with water, thoroughly dry the instrument with a dry, lint-free cloth.
  •  There are no user serviceable parts in this instrument.

FEATURE DETAILS

  1.  Horizontal Line On/Off Button
  2.  Vertical Line On/Off Button
  3.  Plumb Spot On/Off Button
  4.  Low Battery Indicator
  5. Excessive Tilt Indicator
  6. Power/Pendulum Lock/Unlock Switch
  7. Pendulum with Lasers
  8.  Horizontal Line Aperture
  9. Vertical Line Aperture
  10.  Plumb Spot Aperture
  11.  Battery Compartment Door
  12. 1/4-20 Tripod Mount
  13. 5/8-11 Survey Tripod Mount
  14. Magnetic Mount Bracket
  15. Magnets
  16.  Clamp-On Wall Adapter

NOTE: There are no user-serviceable parts inside this instrument.

KLEIN TOOLS 93LCLG Self-Leveling Green Cross Line Laser Level with Red Plumb
Spot fig 2

SYMBOLS ON INSTRUMENT

KLEIN TOOLS 93LCLG Self-Leveling Green Cross Line Laser Level with Red Plumb
Spot fig 4

OPERATING INSTRUCTIONS

TURNING LASER BEAMS ON/OFF
Push the ON/OFF buttons for the horizontal line 1 , vertical line 2 , and plumb spot 3 to turn ON and OFF their respective laser lines. These buttons are only active once the Pendulum Lock/Unlock Slider Switch 6 has been set to the Unlocked position. If the Pendulum Slider Switch is moved from the Unlocked to the Locked position while the laser beams are active, they will be turned OFF. The different laser lines can be operated independently or simultaneously.

KLEIN TOOLS 93LCLG Self-Leveling Green Cross Line Laser Level with Red Plumb
Spot fig 5 NOTE: The plumb spot application projects laser beams both in upward and downward directions. The downward beam may be used to locate a specific point on a floor layout while the upward beam projects that same point to a ceiling.

PENDULUM SLIDER SWITCH & SELF-LEVELING
The laser assemblies are mounted on a pendulum so that the instrument can self-level. The Pendulum Slider Switch 6 must be in the unlocked position for the instrument to self-level. If the instrument is tilted by >4° from the horizontal plane, the pendulum will not be capable of self-leveling; the active laser beams will flash and the Excessive Tilt Indicator 5 will blink to indicate that the instrument is not level and cannot self-level. The instrument must be repositioned on a more level geometry for the self-Leveling pendulum to function appropriately.

NOTE: If the instrument indicates that it is not level (via flashing beams and/or a blinking Excessive Tilt indicator 5 ), then it should not be used for laying out level or plumb lines.
NOTE: Following use, the active laser beams must be turned OFF and the Pendulum Slider Switch must be placed in the Locked position prior to storage.

MAGNETIC MOUNTING BRACKET 14
The instrument is attached to a magnetic mounting bracket. The bracket may be magnetically attached to any magnetic structure such as steel studs, ducts, structural beams, and steel doors. The bracket also features a key-hole for mounting the instrument using a screw or nail to non-magnetic structures. Once mounted to a structure via the mounting bracket the instrument can be rotated on the bracket through 360° to direct the laser beams. KLEIN TOOLS 93LCLG
Self-Leveling Green Cross Line Laser Level with Red Plumb Spot fig
7 CLAMP- ON WALL ADAPTER 16
The clamp-on wall adapter may be clamped to a structural beam, or wall bracket for suspended ceiling installations, to present a steel surface onto which the instrument’s magnetic mounting bracket may be attached. Once magnetically attached the instrument may be positioned to deliver the laser line at the required location. The clamp-on adapter also features a key-hole for mounting the instrument using a screw or nail. KLEIN TOOLS 93LCLG Self-Leveling Green
Cross Line Laser Level with Red Plumb Spot fig 8

MAINTENANCE

BATTERY REPLACEMENT
When the Low Battery indicator 4 is illuminated red, the batteries must be replaced.

  1.  Open the battery compartment door 11 .
  2. Remove and recycle three spent AA batteries.
  3.  Install new batteries (note proper polarity).
  4.  Close battery compartment, ensuring that it is securely shut.

  CLEANING

Be sure meter is turned off and wipe with a clean, dry lint-free cloth. Do not use abrasive cleaners or solvents.

STORAGE

Remove the batteries when the instrument is not in use for a prolonged period of time. Do not expose to high temperatures or humidity. After a period of storage in extreme conditions exceeding the limits mentioned in the General Specifications section, allow the meter to return to normal operating conditions before using.

WARRANTY

www.kleintools.com/warranty

DISPOSAL / RECYCLE

Do not place equipment and its accessories in the trash. Items must be properly disposed of in accordance with local regulations. Please see www.epa.gov or www.erecycle.org for additional information.

CUSTOMER SERVICE

KLEIN TOOLS, INC.
450 Bond Street Lincolnshire, IL 60069
1-877-775-5346
customerservice@kleintools.com www.kleintools.com

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

KLEIN TOOLS User Manuals