Simplex 2099-9757 Single Action Model Pull Station Instruction Manual
- June 6, 2024
- Simplex
Table of Contents
UL, ULC, CSFM Listed;
FM Approved MEA (NYC)
*Acceptance
Multi-Application Peripherals
Non-Coded, Non-Addressable Manual Stations; 2099 Series Single and Double
Action
Operation**
Features
Manual fire alarm stations for general purpose applications:
- Operation complies with ADA requirements
- Pull lever protrudes when alarmed
- Break-rod is supplied, use is optional
- Screw terminals for wiring connections
- Tamper-resistant reset key lock (keyed same as Simplex fire alarm cabinets)
Operation types include:
- Single action
- Double Action, Breakglass or Push Type
- Institutional Model, key-operated only
- Optional NO GRIP Single Action Retrofit Kits are available with a more easily operated pull lever for applications where anticipated users may find the standard station lever difficult to activate
- Optional Local Alarm cover
- Optional pre-signal and annunciator contacts
Multiple mounting options:
- Surface or semi-flush with standard boxes or matching Simplex boxes
- Flush mount adapter kit
UL listed to Standard 38
Operation
Activation of the Simplex single action manual stations requires a firm
downward pull to activate the alarm switch. Completing the action breaks an
internal plastic break-rod which is visible below the pull lever, use is
optional. The use of a break-rod can be a deterrent to vandalism without
interfering with the minimum pull requirements needed for easy activation. The
pull lever latches into the alarm position and remains extended out of the
housing to provide a visible indication.
Double Action Stations (Breakglass) require the operator to strike the front-
mounted hammer to break the glass and expose the recessed pull lever. The pull
lever then operates as a single action station.
Double Action Stations (Push Type) require that a spring-loaded interference
plate, which is marked PUSH, be pushed back to access the pull lever of the
single action station.
Station reset requires the use of a key to reset the manual station lever and
deactivate the alarm switch. If the break-rod is used, it must be replaced.
Station testing is performed by physical activation of the pull lever.
Electrical testing can be also performed by unlocking the station housing to
activate the alarm switch.
Figure 1: Single Action Station| Figure 2: Double Action Station (Push Type)
Figure 3: Double Action
Station (Breakglass)| Figure 4: Local Fire
Alarm Cover Option
Figure 5: Single Action Station with Institutional Cover| Figure 6: 4099-9805
NO GRIP Retrofit kit
Institutional Stations activate by key operation only allow access for
manual alarms to be initiated by authorized personnel. Operation requires key
insertion and opening of the station cover.
Single Action Station NO GRIP Retrofit Kit 4099-9805. For applications
such as California Building Code, Title 24, which requires
“Controls and operating mechanisms shall be operable with one hand and shall
not require tight grasping, pinching or twisting of the wrist” the model
4099-9805 Retrofit kit provides a more easily operated pull lever compared to
standard stations.
Pre-Signal Option activates when the lever is pulled. General alarm
initiation requires a key to activate a key switch located behind the pull
lever.
Station Reset requires the use of a key to reset the manual station lever
and deactivate the alarm switch. If the break-rod is used, it must be
replaced.
Testing requires physical activation of the pull lever, except for
institutional stations.
- These products have been approved by the California State Fire Marshal (CSFM) pursuant to Section 13144.1 of the California Health and Safety Code. See CSFM Listing 7150-0026:175 (Pull Boxes) and 7150-0026:0224 (NO GRIP Retrofit Kit) for allowable values and/or conditions concerning material presented in this document. Additional listings may be applicable; contact your local product supplier for the latest status. Listings and approvals under Time Recorder Co. are the property of Tyco Fire Protection Products. S2099-0007 Rev. 19 02/2021
Non-Coded, Non-Addressable Manual Stations; 2099 Series Single and Double Action Operation
Application reference
Refer to NFPA 72, the National Fire Alarm and Signaling Code, and all
applicable local codes for complete requirements for manual stations.
The following summarizes the basic requirements.
- Stations shall be located in the normal path of exit and distributed in the protected area such that they are unobstructed and readily accessible.
- Mounting shall be with the operable part not less than 42 in. (1.07 m) and not more than 48 in. (1.22 m) above floor level.
- At least one station shall be provided on each floor. Additional stations shall be provided to obtain a travel distance not more than 200 ft (61 m) to the nearest station from any point in the building.
- When manual station coverage appears limited in any way, additional stations should be installed.
Product selection
Table 1: Single action models (General alarm)
Model| MENU| Pre-signal| Annunciator
contacts, N.O.| Annunciator
contacts, N.C.| Institutional
Local alarm cover| cover| Mounting
notes
---|---|---|---|---|---|---|---
2099-9754| Yes| —| —| —| —| —| 1
2099-9101| Yes| —| Yes| —| —| —|
2099-9102| Yes| —| —| Yes| —| —
2099-9107| —| Yes| Yes| —| —| —|
2099-9755| Yes| —| —| —| Yes| —| 1
2099-9762| Yes| —| —| —| —| Yes| 1
Table 2: Double action models (General Alarm)
SKU| MEA| Break-glass| Push| Pre-signal|
Annunciator
contacts N.O.| Annunciator
contacts N.C.| Mounting
notes
---|---|---|---|---|---|---|---
2099-9103| Yes| Yes| —| —| —| —| 1
2099-9104| Yes| Yes| —| —| Yes| —| 2
2099-9756| Yes| —| Yes| —| —| —| 1
2099-9757| Yes| —| Yes| —| Yes| —| 2
2099-9758| Yes| —| Yes| —| —| Yes
Table 3: Accessories
Model | Description |
---|---|
4099-9805 | Retrofit Kit for field conversion of a single action station to a |
NO GRIP station; (reference Instructions 579-1007)
2099-9803| Replacement break glass (standard, English)
2099-9804| Replacement break-rod
2099-9819| Flush adapter kit, black (refer to page 4)
2099-9820| Flush adapter kit, beige (refer to page 4)
2099-9822| Replacement retaining clip for break glass
2099-9828| Institutional cover kit
2975-9178| Red, surface mount box, sheet metal, 5 3/16 in. H x 4 in. W x 2
3/16 in. D (127 mm x 102 mm x 56 mm)
2975-9022| Red, cast aluminum surface mount box, 5 in. H x 3 7/8 in. W x 2
3/16 in. D (127 mm x 98 mm x 56 mm)
252-019| B key for manual station reset
Note:
1. These models can be semi-flush mounted using a standard single gang 2 1/5
in. (64 mm) deep switch box. DO NOT RECESS BOX, mount box flush or with 1/16
in. (2 mm) maximum protrusion. These models can also be surface mounted on a
Wiremold box model number V5744S, 4 5/8 in. H x 2 7/8 in. W x 2 1/4 in. D (117
mm x 73 mm x 57 mm).
2.For surface mount, these models require 2975-9178 or 2099-9022 boxes. For
semi-flush mount, these models require a 4 in. (102 mm) square box with a
single gang cover plate (see diagram on page 3).
Additional manual station reference
| Datasheet| Addressable manual stations| Datasheet
---|---|---|---
Non-addressable manual
stations| S2099-0010| Standard addressable| S4099-0005
Releasing stations| Wire guard (addr./non-addr.)| S2099-0004
Non-addressable manual stations| Datasheet| Addressable manual stations|
Datasheet
---|---|---|---
Releasing stations| S2099-0010| Standard addressable| S4099-0005
Stations for hazardous locations (Ring-Pull)| S2099-0008| Addressable for
releasing| S4099-0006
Metal housing and explosion-proof/weather-proof stations (T-Handle)|
S2099-0009| Wire guard (addr./non-addr.)| S2099-0004
Surface mounting reference
Note : Figure shows 2975-9178 box and 2975-9022 cast box.
Semi-flush mounting reference
Flush mount reference
Note : Figure shows 2099-9819 (black) and 2099-9820 (beige) flush mount adapter kit.
Specifications
Table 4: Specifications
Specification | Rating |
---|---|
Wire connections | Screw terminal for in/out wiring, for 18 AWG to 14 AWG |
wire
UL listed temperature rang| 32°F to 120°F (0°C to 49°C) intended for
indoor operation
Humidity range| Up to 93% RH at 100°F (38°C)
Housing color| Red with white raised lettering
Material| Housing and pull lever are high impact polycarbonate
Pull lever color| White with red raised lettering
Housing dimensions| 5 in. H x 3 3/4 in. W x 1 in. D (127 mm x 95 mm x 25
mm)
© 2021 Johnson Controls. All rights reserved. All specifications and other
information shown were current as of document revision and are subject to
change without notice. Additional listings may be applicable, contact your
local Simplex® product supplier for the latest status. Listings and approvals
under Simplex Time Recorder Co. Simplex and the product names listed in this
material are marks and/or registered marks. Unauthorized use is strictly
prohibited. NFPA 72 and National Fire Alarm Code have registered trademarks of
the National Fire Protection Association (NFPA).
S2099-0007 Rev. 19 02/2021