FIRST DEGREE FITNESS E520 Fluid Rower User Guide

June 6, 2024
FIRST DEGREE FITNESS

FIRST DEGREE FITNESS logo E520 Fluid Rower
User Guide

 Monitor and Sensor Trouble Shooting

Guide

This document applies to E520, VX‐3 Rowers, and E620, E720, E820 and E920 Upper Body Ergos

FIRST DEGREE FITNESS E520 Fluid Rower

Basic Checks

  1. Monitor Displays Nothing
    • Check batteries and replace if necessary

  2. Abnormal Readings
    • Monitor Display is normal but readings do NOT update when exercising
    • Monitor readings fluctuate, i.e. are not consistent, during exercise
    • Monitor displays 59:59 for 500mTime (Rowers Only)

These symptoms indicate an issue with either the speed sensor assembly or the wiring between sensor and monitor.  To resolve the issue follow the step‐by‐step instructions below until the normal function resumes.

Troubleshooting

STEP 1: Remove and replace batteries

STEP 2: Check Sensor Connector at rear of Monitor

  • Disconnect and re‐connect then test monitor input before proceeding.
  • Check for obvious sensor cable damage.

FIRST DEGREE FITNESS E520 Fluid Rower - STEP 2

STEP 3: Remove the access panel behind the water tank – check connector and for cable damage.
FIRST DEGREE FITNESS E520 Fluid Rower - STEP 3

STEP 4: Check Sensor Assembly

  • Use a small mirror to check the six magnets in the sensor wheel
  • Check the distance between the sensor and sensor wheel is between 0.5 and 3mm, closer is better.
  • If adjustment is required, remove the sensor bolt and increase or decrease the spacing by adding or removing a spacer washer. Re‐install sensor bolt.

FIRST DEGREE FITNESS E520 Fluid Rower - STEP 4

If steps #1 to #4 fail to resolve the issue then the problem is with the sensor itself and it will need to be replaced.
STEP 5: Replacing the Sensor (see images below)

  1. Remove the access panel, if not already done

  2. Remove sensor bolt

  3. Pull out the cable holder from the sidewall and cut the cable tie

  4. Disconnect the sensor connector

  5. Remove old sensor
    • Pushout

  6. Install new sensor
    • Push‐fit

  7. Connect sensor connector

  8. Install and tighten sensor bolt

  9. Check the distance between the sensor and sensor wheel is between 0.5 and 3mm, closer is better.

  10. If adjustment is required, remove the sensor bolt and increase or decrease the spacing by adding or
    removing a spacer washer. Re‐install sensor bolt.

  11. Use a cable tie to re‐secure the sensor cable

  12. Check and ensure that the sensor cable does not interfere with the main drive belt

  13. Test  before re‐attaching the access panel
    FIRST DEGREE FITNESS E520 Fluid Rower - STEP 5FIRST DEGREE FITNESS E520 Fluid Rower - STEP
6

STEP 6: Replacing the Monitor

  1. Disconnect the connectors at the rear of the monitor
  2. Remove the securing nut and bolt from the monitor support stalk
  3. Replace with the new monitor
  4. Re‐install securing nut and bolt
  5. Re‐connect both connectors

FIRST DEGREE FITNESS E520 Fluid Rower - STEP 8

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

FIRST DEGREE FITNESS User Manuals

Related Manuals