Safety

Safety Information

  •  Before using this product, it is essential to read this ENTIRE operation manual and ALL instructions. The unit is intended for use solely in the manner described in this manual.
  •  UNDERSTANDING EACH AND EVERY WARNING TO THE FULLEST IS IMPORTANT
  •  As with any piece of fitness equipment, consult a physician before beginning your exercise program.
  •  Please be aware that any fitness regiment, before being undertaken, is best preceded by a physical checkup from a certified physician.
  •  Injuries to health may result from incorrect or excessive training.
  •   WARNING Heart rate monitoring systems may be inaccurate. Over-exercise may result in serious injury or death. If you feel faint, stop exercising immediately.
  •  Do not allow children unattended access to the machine.
  •  Please keep hands away from moving parts, as indicated by the warning label on the Main Frame of your machine.
  •  If any of the adjustment devices are left projecting, they could interfere with the user’s movement.•
  • Do not store in freezing conditions with water in the tank as it can expand and crack the components.

Installation

  • Place on a stable, flat surface in a horizontal position during use for maximum stability.
  •  Check regularly and follow all instructions for maintenance as specified in this manual.
  •  Replace immediately any defective parts and do not operate the unit until all repairs are complete.

Proper Usage

  • Do not use any equipment in any way other than designed or intended by the manufacturer. It is imperative that FIRST DEGREE FITNESS equipment is used properly to avoid injury.
  •  Injuries may result if exercising improperly or excessively. It is recommended that all individuals consult a physician prior to commencing an exercise program. If at any time during exercise you feel faint, dizzy or experience pain, STOP EXERCISING and consult your physician.
  •  Keep body parts (hands, feet, hair, etc.), clothing, and jewelry away from moving parts to avoid injury.
  •  Follow instructions provided in this manual for correct foot position and basic exercise techniques.
  •  For more detailed exercising techniques, please refer to our International website www.firstdegreefitness.com

Inspection

  • DO NOT use or permit use of any equipment that is damaged and/or has worn or broken parts. For all FIRST DEGREE FITNESS equipment use only replacement parts supplied by FIRST DEGREE FITNESS.
  •  EQUIPMENT MAINTENANCE – Preventative maintenance is the key to smooth operating equipment as well as to keeping your liability to a minimum. Equipment needs to be inspected at regular intervals.
  •  Ensure that any person(s) making adjustments or performing maintenance or repair of any kind is qualified to do so.
  •  DO NOT ATTEMPT TO USE OR REPAIR ANY ACCESSORY APPROVED FOR USE WITH THE FIRST DEGREE FITNESS EQUIPMENT WHICH APPEARS TO BE DAMAGED OR WORN.
  •  Check regularly and follow all instructions for maintenance as specified in this manual.
  •  Replace immediately any defective parts and do not operate the unit until all repairs are complete.

Operating Warnings

  • Keep children away from the equipment. Parents or others supervising children must provide close supervision of children if the equipment is used in the presence of children.
  •  Do not allow users to wear loose-fitting clothing or jewelry while using the equipment. It is also recommended to have users secure long hair back and up to avoid contact with moving parts.
  •  All bystanders must stay clear of all users, moving parts, and attached accessories and components while the machine is in operation.
  • WARNING Do not insert fingers into the tank!

Assembly

  • Product Specifications
  • Product Class: SC
  • Braking System: Speed Independent
  • Product Net Weight: 90kg (198lb)
  • Product Gross Weight: 110kg (242lb)
  • Maximum Safe Operating Surface Area: 301cm (108.27”) Length x 222cm (87.40”) Width
  • Dimensions: 1810mm (71.26”) Length x 1020mm (40.16”) Width x 1480mm (58.27”) Height Maximum User Weight: 150kg (330lb)FIRST DEGREE FITNESS E950 Fluid Exercise FIG 1

E950 Box 1 & 2 Contents

Item| Qty .| Description| Item| Qty.| Description
---|---|---|---|---|---
1| 1| Main Frame with Telescoping Tube

and Internal Gas Assist Shock

| 10| 2| Plastic Spacer
2| 1| Baseplate| 11| 1| 3mm Allen Key
3| 1| Seat Frame| 12| 9| Foot Levelers
4| 1| Seat Back| 13| 1| Multi-tool
5| 1| Lower Seat| 14| 2| D Cell Battery
6| 1| Slider Arm Assembly Left| 15| 1| Touch Up Paint
7| 1| Slider Arm Assembly Right| 16| 1| Funnel and Hose
8| 2| Handle Lock Knob| 17| 1| Owners Manual
9| 2| M12 Washer|  |  |
Hardware  KIT
18| 8| M6x20mm Bolt| 26| 8| M6 Washer
19| 4| M8x15mm Bolt| 27| 8| M8 Washer
20| 8| M8x20mm Bolt| 28| 3| M10 Washer
21| 4| M8x25mm Bolt| 29| 4| M8 Springs Washer
22| 8| M8x45mm Bolt| 30| 1| Handle Bar & Nut Dome Head
23| 3| M10x20mm Bolt| 31| 1| 4mm Allen Key
24| 4| M8 Nylock Nut| 32| 1| 6mm Allen Key
25| 2| M10 Nylock Nut| 33| 4| Water Treatment Tablet

Assembly Instructions

Main Frame Assembly Instructions

a) Attach Telescoping Tube to the underside of the control arm using 4x M8x15mm Bolts[19] and 4x M8 Spring Washers[29].
b) Thread the 3x Foot levelers[12] into underside of base. Adjust as required.

Slider Arm Kit Installation Instructions

Assembly Instructions

Step 1   Installing Baseplate to the Main Frame

3x M10x20mm Bolts[20], 2x M10 Nylock Nut[25] and 3x M10 Washers[28]. Secure tightly.

Installing Baseplate to the Main Frame

b) Attach Left and Right Ramps to the T-Track using 8x M8x45mm Bolts[22].
c) Once the Left and Right Ramps have been installed to the sides of the T-Track, secure the front end of each Ramp as shown using 4x M8x25 Bolts[21], 4x M8 Nylock Nut[24] and 8x M8 Washers[27].

Installing Seat Assembly

  •  Thread the Handle Bar[30] through the Shaft
  •  Tighten the Handle Bar[30] with the M10 Dome Nut[30] .
  •  Install Seat Back[4] with 4x M6x20 Bolts[18] and M6 Washer[26].
  •  Install Lower Seat[5] with 4x M6x20 Bolts[18] and M6 Washer[26].

Installing Seat to the Main Frame

Baseplate Track. Must ALWAYS be in the LOCKED position when Seat is occupied on Baseplate. Must be lowered to allow Seat removal. To LOCK, raise and locate. To UNLOCK, lift and drop rearward.
b) Seat Installation: Tilt the Seat slightly upward to allow the front Rollers to engage the channel. Then, lift the rear level and, while engaging the Seat Lock Release Lever, slide the seat onto the Baseplate as shown. Usage: The Seat has four positions. To move forward or rearward, depress the Seat Lock Release Lever and move freely to whichever position you require.

c) To remove the Seat: Lift and lower the Rear Safety lock, depress the Seat Lock Release Lever and slide the Seat rearward.

Operation Instructions

E950 Control Arm

Chain Tensioning Bolts: Allows for tightening the Chain or adjustment from side to side. Make sure when tightening only to adjust the same amount for both Bolts, otherwise the sprocket will be misaligned. Tightening the right Bolt only (turning clockwise) will pull the right side of the Crank assembly toward you, tightening the left will pull the left side toward you. Use this feature to realign the rear with the front sprocket if needed or when changing to a new Chain.

Slider Arm Kit Installation Instructions

a) Mount the left Slider Arm onto the Axle using the yellow indicator hole to align the slider and axle.
b) Tighten the set screw onto the Axle and into the yellow indicator hole using the 3mm Allen key.
c) Thread Adjustment Knob onto the Axle to secure the assembly.
d) Repeat steps 1-3 to install right Slider Arm onto the Axle.

Using Slider Arm

The E950 Slider Arm Kit offers the user an entire range of added resistance settings and the ability to perform additional upper body workouts. To adjust, simply loosen the Adjustment Knobs, move Slider Arm to the desired length, and secure. Very little tension is needed.
What do the numbers mean?
The numbers represent the length (in cm) from the center of the Axle to the center of the Handgrip Shaft Bolt. The shortest Slider Arm length is 12cm and the maximum length is 21cm. The range of adjustment is 9cm.

Additional Exercises

  • Training can now be achieved with both left and right Handgrips moving parallel, rather than in an opposed motion
  • On the right Slider Arm Assembly, remove the Adjustment Knob, loosen set screw, and remove Assembly from the Axle.
  •  As shown below, rotate right Slider Arm 180 degrees and reinstall onto the Axle. There is an additional screw locator hole located on the opposite side of the axle.

Tank Filling and Water Treatment

a) Filling requires a large bucket (not supplied) and the supplied water Funnel and Hose[16]. A filling will take approximately 8 liters of water.
b) Open the Tank Plug on the back of the Tank and insert the hose (rotating the impeller slightly may be necessary to allow the hose to pass). In areas where tap water quality is known to be poor, FDF recommends the use of distilled water.
c) Move the Tank adjuster handle to level 10 and begin filling. Do not fill the Tank higher than the level indicator on the front of the clear shell.
d) Once filling is complete follow the Water Treatment schedule below.

NOTE: For simple, fast and efficient filling and/or drainage of the Fluid Tank, we have a battery-operated pump (rechargeable via USB) available as an option. We recommend this to any commercial facility, with multiple units, that has a need to drain and refill Tanks from time to time. To purchase, contact your nearest First Degree Fitness distributor or go to our website on www.firstdegreefitness.com for details.
INITIAL WATER TREATMENT
Add One Water Treatment Tablet per full Tank. Do NOT, UNDER ANY CIRCUMSTANCE, USE A WATER TREATMENT TABLET OTHER THAN THOSE SUPPLIED WITH YOUR UNIT. Your unit purchase includes 4xWater Treatment Tablets, which are sufficient for several years of use. To purchase additional Water Treatment Tablets, please consult your nearest regional dealer/distributor or check our website at www.firstdegreefitness.com

CHANGING RESISTANCE LEVEL
Changing resistance on your Unit is simple. The level of resistance is determined by the level indicator located on the front of the Tank. Level one indicates the lightest resistance, level ten represents the heaviest resistance. The Tank’s variable fluid resistance technology ensures an instant catch and constant resistance throughout the movement.
Your Unit Monitor will automatically adjust to the resistance level selected on the Tank. Allow three to four seconds after adjusting the resistance handle for the correct resistance level to be achieved.

LONG-TERM WATER TREATMENT
WARNING: DO NOT USE ANY OTHER WATER TREATMENT TABLET OTHER THAN THOSE SUPPLIED WITH YOUR UNIT.
The amount of time between water treatments can vary greatly depending on your unit’s location and exposure to sunlight. Typically you can expect to treat your Tank water every 12-24 months. If the water becomes discolored or shows signs of algae / bacterial growth simply add one Water Treatment Tablet.

Bluetooth Auto-Adjust Monitor

Auto Start: Commence exercise to activate.
Reset all values: Press and hold the RESET button for 3 seconds.
Auto Power Down: Over 5 minutes. All values revert to zero after the restart.

WATT: Measures peak power in watts, calculating the strength and acceleration provided to accurately measure a user’s power.

TRAINING DATA: Data gathered from each workout is displayed in a power curve and cumulative power graph, enabling real-time comparisons for effective progressive training.
AUTO ADJUST LEVEL: Built-in potentiometer automatically adjusts the Monitor’s resistance level according to the position of the Fluid Force Lever on the tank. BLUETOOTH CONNECTIVITY: Each unit is fitted with the most advanced Monitor technology, enabling Bluetooth connectivity with any compatible smart device. The Monitor will assist with effective training progression, capturing and comparing data for the competitive individual. It is compatible with 3rd party APP and Software Update via Bluetooth.
NOTE: Heart Rate Chest Strap is sold separately.

WARNING
Heart rate monitoring systems may be inaccurate, Over-exercising may result in serious injury or death. If you feel faint stop exercising immediately and seek professional medical advice.

Calibration Procedure

Edit Post ‹ Manuals+ —
WordPress

Maintenance & Troubleshooting

For further information, manuals, and warranty requests visit www.firstdegreefitness.com/support

For further information, manuals and warranty requests visit

www.f i rs t d e gr ee f i t n e ss . c o m / s u p p o rt


Problem| Solution
Water changer color or becomes cloudy.| Change Unit location to reduce direct exposure to sunlight. Add water treatment or change Tank water as directed in the water treatment section of this manual. Consider using distilled water to refill Tank.
I want to drain the fluid Tank on my E950.| It is recommended to take your unit outdoors, open the Tank Plug, and lay unit on its back to facilitate draining process.

For simple, fast and efficient filling and/or drainage of the Fluid Tank, we have a battery operated pump (rechargeable via USB) available as an option. We recommend this to any commercial facility, with multiple units, that has a need to drain and refill Tanks from time to time. To purchase, contact your nearest First Degree Fitness distributor or go to our website on www.firstdegreefitness.com for details.

The Monitor display is erratic and illuminates, but does not register with movement.| It is possible that there is a loose connection. Check that the Monitor lead is connected properly to the unit. If connected properly check Sensor gap. Contact your local dealer if this fails

to address the problem.

The Monitor does not illuminate after battery installation.| Replace/reinstall batteries in correct position and try again. If the LCD screen fails to illuminate, try rotating the                       bat- teries slightly in the Monitor.

If this fails, contact your local service center.

Knocking noise from inside the Control Arm while training, especially when changing directions

Chain requires tightening or adjustment.

| Open Inspection Plate located on front of Control Arm and check tension using a screwdriver or other tool. Use the chain Tensioning Bolts located at the rear of the Control Arm to tighten or adjust as needed. The Chain should have approx. 3mm of slack when properly adjusted. See P.13 for

details.

Pedal is loose (either left or right) and cannot be retightened.

Aluminum crank arm threads are stripped.

| Contact service center for replacement. Then check weekly as recommended.
Pedals slip during hard training. PK Tank Belt requires tightening.| Remove large Inspection Plate next to the Tank, insert a long tool to push the rear end cap out from the inside, exposing the Tank Belt Tensioning Bolt. Loosen Tank Bolts slightly. Remove upper Rubber Belt cover to expose the PK belt. Tighten the Tank Tensioning Bolt until the Belt is too tight to be twisted from side to side more than 45 degrees

by hand.

The Monitor LEVEL is not synchronized with the Tank LEVEL.| The Monitor LEVEL needs to be recalibrated. Please refer to “Calibration Procedure” page 20 of this manual.

Item Time Frame I nstru c ti on s

Seat and Frame.

|

Weekly.

| Wipe down weekly with lint free cloth or more often with heavy club use.

PK Belt Tension.

|

Monthly.

| Check monthly for signs of slippage. Adjust/tighten as required.

Tank and Water Treatment.

|

12 months to 2 years.

|

Follow instructions as specified in the “Water Treatment” section of this manual.

Chain Drive.

|

Check every 100 hours for correct

tension.

|

Open the Inspection Plate and check tension using a screwdriver or other tool. Tighten as required using chain Tensioning Bolts located at the end of the Control Arm.

Handle Assembly.

|

Check weekly using Multi- Tool (supplied) to ensure Handle Assembly is securely tightened into Crank Arm.

|

The handle should be checked on a regular basis. Continued use of a loose Handgrip can cause

damage to the Crank Arm threads, necessitating replacement.

To ensure maximum lifespan and optimal performance follow these steps:

1. Keep your E950 in a dry, clean climate-controlled environment at room temperature.
2. Only treat water with FDF genuine Water Treatment Tablets. Refer to the ‘Water Treatment’ section on page 17.
3. Periodically clean your machine with disinfectant, applied using a lint- free cloth.
4. Wipe dust off the machine.
5. For information on how to service your machine visit
firstdegreefitness.com/support

Tank Belt Adjustment

1. Remove large metal inspection plate.
2. Using a long tool, push out the rear end cap as pictured below left. This will give you access to the tank

3. Loosen both the rear and front tank Bolts slightly as shown. Remove front Rubber Belt Cover.
4. Using a 6mm Allen Key, tighten the Belt using the Tank Tensioning Bolt until the belt no longer slips during hard rowing.

Note: Do not over-tighten tank Bolts.

Tip: Twist the Belt by hand to gauge tightness. Correct tension should be obtained when no longer able to twist more than 45 degrees

International Warranty

FULL COMMERCIAL USE

This product is designed and constructed for use in any Health Club / Fitness Studio application First Degree Fitness Limited warrants that the E950 Med/Rehab UBE (model E950), purchased from an authorized agent and in its undamaged original packaging, is free from defects in materials and workmanship. First Degree Fitness Limited or its agent will, at their discretion, repair or replace parts that become defective within the warranty period, subject to the specific inclusions and exclusions below.
Metal Frame – 10 Year Limited Warranty First Degree Fitness will repair or replace the metal Main Frame should it fail due to any defect in materials or workmanship within 10 years of the original purchase. Warranty does not apply to frame coating. Polycarbonate Tank & Seals – 5 Year Limited Warranty First Degree Fitness will repair or replace the polycarbonate tank or seals should they fail due to any defect in materials or workmanship within 5 years of the original purchase. Mechanical Components (of a non-wearing nature) – 2 Year Limited Warranty First Degree Fitness will repair or replace any mechanical component should it fail due to any defect in materials or workmanship within 2 years of the original purchase.
All Other Components (of a wearing nature) – 2 Year Limited Warranty First Degree Fitness will repair or replace any component should it fail due to any defect in materials or workmanship within 2 years of the original purchase. Specific Inclusions Handgrip assemblies Seat All rubber components Monitor & speed Sensor (excluding replaceable batteries) All drive belts & chains Crank arms All pulleys, rollers & bearings General Exclusions Damage to the finish of any part of the machine Damage due to neglect, abuse, incorrect assembly or use of the machine Any charges for freight or customs clearance associated with the return or dispatch of parts Any damage to or loss of goods during transport of any kind Any labor cost associated with a warranty claim

General Conditions

  • The serial number of the machine must be correctly registered with First Degree Fitness Limited or one of its appointed distributors
  •  First Degree Fitness Limited reserve the right to examine any part where replacement is claimed under warranty
  •  The warranty commences at the time of sale but no later than six (6) months from the date of the original shipment
  •  The warranty period applies only to the original purchaser from the date of purchase and is not transferable
  •  The product must be returned to your place of purchase in original packaging with transportation, insurance, and associated charges paid for by you and risk of loss or damage assumed by you
  •  First Degree Fitness makes no other warranties except as stated here and expressly disclaims all warranties not stated in this warranty. Neither First Degree Fitness nor its associates shall be responsible for incidental or consequential damages
  •  Manufacturer’s warranty automatically commences upon sale of the product to end-user or upon the expiration of one (1) year from month of manufacture, whichever occurs first