DRIEAZ 104411 Cube Dehumidifier Owner’s Manual
- June 5, 2024
- DRIEAZ
Table of Contents
- DRIEAZ 104411 Cube Dehumidifier
- WARNING
- INSTRUCTIONS
- CONTROL PANEL
- Plug-in the electrical cord
- Parts Identification
- USER SETTINGS
- MAINTENANCE SCHEDULE
- Inspect Pump Filter
- Before each use
- Disassembly for Cleaning
- SYSTEM MESSAGES
- ERROR MESSAGES
- TROUBLESHOOTING
- SPECIFICATIONS
- References
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
DRIEAZ 104411 Cube Dehumidifier
WARNING
- Electric shock hazard, rotating fan hazard and hot surface hazards.
- Inspect the power cord before use. If cord is damaged, do not use. Always grasp the plug (not the cord) to unplug.
- Must be earthed. Insert three-prong plug on power cord into a matching electrically earthed outlet. Do not use adapter. Never cut off third prong. Do not use an extension cord.
- The unit must be operated on a 230V or 110V 50 Hz circuit protected by a Residual Current Device (RCD) device, depending on model.
- Keep motor and wiring dry.
- Always unplug unit before cleaning or servicing.
- Do not attempt to repair the unit. For service, contact your local distributor.
- FIRE HAZARD
- Keep away from open flames and heat sources.
- Do not use or store where vapors from gasoline, solvents, thinners or other flammable materials may be present.
BEFORE YOU BEGIN : Warranty registration
Warranty registration procedures vary by country/market. Contact your local
distributor for assistance. Registration allows us to better assist you with
using, maintaining and servicing your equipment and to contact you in case we
have important safety information concerning your Dri-Eaz product. If you
determine service is required, have your equipment model, serial number and
original proof of purchase available and ask for assistance with obtaining a
return material authorization (RMA).
INSTRUCTIONS
GROUNDING INSTRUCTIONS
This unit’s plug must be inserted into an appropriate outlet that is properly
installed and grounded in accordance with all local codes and ordinances.
WARNING! Improper connection of the equipment-grounding conductor can result
in a risk of electric shock. Check with a qualified electrician or service
person if you are in doubt as to whether the outlets are properly grounded. Do
not modify the plugs provided with the appliance – if the plugs do not fit the
outlets, have proper outlets installed by a qualified electrician. This
equipment is for use on circuits with a nominal rating of no more than 230V.
Handle the unit carefully
Always operate the unit on a stable, level surface. Do not drop, throw, or
place where it could fall. Rough treatment can damage the unit, and may create
a hazardous condition or void the warranty. This unit intended for household
and commercial use.
CONTROLS AND OPERATING INSTRUCTIONS
Set unit upright NOTICE: Always store, transport, and use the unit in a
horizontal position. If the unit is ever placed in a vertical position, return
it to the horizontal position and let it stand for at least 30 minutes before
turning it on.
CONTROL PANEL
Positioning a Dehumidifier
For best results, operate your dehumidifiers in an enclosed area. Close all
doors and windows that open to the outside to maximize water removal
efficiency. Place your dehumidifier away from obstructions, and keep it away
from anything that could block airflow into and out of the unit. For more
information about creating an optimum drying environment, contact your local
distributor.
Set up drain hose
Unwrap the entire hose and place the unattached end in a sink, drain, bucket
or outdoors – anywhere that water can drain out safely. If you use a bucket or
other container for water collection, check it regularly to prevent overflows.
Verify hose fitting is attached to short hose exiting the unit. NOTICE :
Uncoil and straighten the entire drain hose. Do not leave any part of the hose
coiled and do not place the end of the hose higher than 6 m above the bottom
of the unit. Also check for kinks or other obstructions that might restrict
the flow of water. Obstructions may cause a water backup and result in
overflows
Plug-in the electrical cord
The unit should be plugged into a 230V/50Hz or 110V/50Hz outlet depending on the model. Startup display and normal display modes When unit is first plugged in to AC power, the control panel display will briefly cycle through a series of
Parts Identification
readouts. This is part of the unit’s self-diagnosis procedure and no user intervention is required
Turn the unit on
The control panel has a display and a touchpad with four keys. Press the
ON/OFF to turn the unit on. The unit will now go through a compressor delay
countdown (up to sixty seconds in duration) and an automatic diagnostics
process.
Once the compressor delay countdown and self-diagnostics are complete, the
display will switch to normal display mode.
The first line of the display shows the total number of hours the unit has
been in operation. This value may be reset to zero to track job hours (see
“Job Hours Reset” below). The second line of the display alternates between
inlet temperature and inlet humidity.
User Settings Menu
A number of display settings may be changed by the user. System information
can also be displayed. These items are accessed by pressing DISPLAY MENU. Each
press of the key will display the next parameter. When you reach the parameter
you wish to adjust, press MENU SELECTION to increase the value. Press DISPLAY
MENU again to accept the setting and re-start the display cycle. Note that
only menu items followed by a greater-than symbol ( > ) may be adjusted. All
settings and modes are discussed in detail in Control Panel Guide.
Error messages
If the onboard diagnostics discover a problem, the unit will display an error
message. See “Error Messages,” p. 8 for an explanation of each message.
Control Panel Guide
-
ON/OFF.
Press to turn the unit on or off. When the machine is turned on, the display normally reads PLEASE WAIT COMP. DELAY and performs a numeral countdown for a maximum of 60 seconds to 0. This delay allows time for refrigerant pressures to equalize for easier starting. Once the unit completes the compressor delay, the display shows UNIT ON XX HRS and cycles between INLET XX°F and INLET XX%. NOTE: If no compressor delay countdown is displayed, a delay is not necessary and the machine will begin operation immediately. -
DISPLAY MENU.
Press to cycle through the display of additional dehumidifier conditions and User Settings. To return to the main menu, press the ON/OFF key once. -
MENU SELECTION.
Press to change the values of the “User Defined” settings. The MENU SELECTION key acts as the UP key for adjusting the setpoint for Humidistat mode operation. See User Settings Menu (below) for details. -
PURGE.
Press to empty water from the condensate pump reservoir. The display will read PUMP PURGING with a numeral countdown. NOTE: During normal operation, the pump purges automatically. -
Changing settings and viewing system information
Display setting changes and system information can be accessed by pressing DISPLAY MENU. Each press of the key will display the next parameter (see list below). When you reach the parameter you wish to adjust, press MENU SELECTION to increase the value. Press DISPLAY MENU again to accept the setting and re- start the display cycle Note that only menu items followed by a greater-than symbol ( > ) may be adjusted.
USER SETTINGS
Only menu items followed by a greater-than symbol (>) may be adjusted. If no keys are selected for 5 minutes on when the screen shows INLET-OUTLET, the display will return to normal display mode. In all the other menu items, the display with return to the normal display mode after 20 seconds. Items without the symbol (>) are for information only and cannot be changed or reset
AT THE END OF THE JOB
To reduce the possibility of drips when moving the unit, follow these
additional steps to ensure that all water is removed from the unit. NOTICE: To
ensure all water is removed from the dehumidifier, the unit will complete the
defrost cycle even if the unit is turned off. If the unit is unplugged during
the defrost cycle, excessive water may accumulate in the unit and may drip out
when you move the unit. If the defrost cycle is interrupted in this way, note
that the unit will display the message POWER FAILURE the next time it is
powered up. To clear the message, press the MENU SELECTION key. NOTICE: To
ensure the condensate tank empties completely while purging, make sure the
unit is placed upright on a horizontal surface.
If the unit is in a defrost cycle, wait until the unit has returned to normal
operating mode before proceeding. To check, review the control panel. The
control panel will show one of the following:
Defrost in progress:
Display mode when unit is in defrost mode. XX indicates the seconds remaining on the defrost cycle
Shutdown Sequence
Display mode when unit in defrost and unit is powered down (shut off by user). Unit will complete the defrost cycle to remove any built-up ice then purge the pump. XX indicates the seconds remaining on the defrost cycle
Drying Sequence
Display mode when unit not in defrost and unit is powered down (shut off by user). Unit will complete the 5 minute drying cycle then purge the pump. XX indicates the seconds remaining on the drying cycle.
Normal Display:
- Wait until the control shows the normal display before proceeding.
- Gently rock the machine to ensure any water remaining on interior surfaces falls into the sump area.
- Press the PURGE key. When the purge cycle is complete, turn the unit off.
- Remove the external drain hose, drain it carefully, coil it and reattach to hose fitting exiting the unit.
- Coil power and store in top compartment.
TRANSPORTATION AND STORAGE
- NOTICE: Handle the unit carefully. Do not drop, throw, or place the unit where it could fall. Rough treatment can damage this equipment and may create a hazardous condition or void warranty.
- Do not expose the control panel to moisture, snow or rain.
- Protect from freezing.
- Store and transport securely to avoid any damaging impact to internal parts.
- Secure during transport to prevent sliding and possible injury to vehicle occupants.
MAINTENANCE SCHEDULE
WARNING! ELECTRIC SHOCK HAZARD. Unplug unit before cleaning or servicing.
WARNING: Risk of dust and contaminants exposure. Use of respirator mask
and gloves is recommended. If unit has been exposed to potentially dangerous
contaminants, clean thoroughly and sanitize before reuse.
NOTICE: The unit is fitted with sensitive electronic sensors. Protect the
sensors and their lead wires from damage and do not expose them to water or
cleaning solution.
The following tools and supplies are needed to complete the maintenance
procedures described in this manual:
- Philips screwdriver
- 3 mm hex bit
- 8 mm nut driver
- Cleaning cloths
- HEPA vacuum cleaner with soft brush nozzle and crevice nozzle.
Inspect Pump Filter
If excessive debris is visible, unscrew filter cap, and rinse cap and filter screen with water. Replace screen and cap and tighten securely
Recommended
Cordless drill, coil cleaning cloths, cleaning solution, cotton swabs, mild
detergent solution.
Before each use
-
Inspect the electrical cord for damage.
Look for fraying, cuts, etc. Replace the cord if you find any damage. -
Inspect air filter
(see Fig A). Replace filter when the accumulation of dust and debris is visible. Do not reuse. Replace only with the 4-PRO air filter #100424 (F587), 24 pk. -
Inspect pump filter
(see Fig. B). If debris is present, unscrew cap, and rinse cap and filter screen clean. Replace screen and cap and tighten securely. -
To maintain appearance,
wipe surfaces with a mild detergent solution.
As Needed
Inspect coils, drip tray, and float switch. Clean when an accumulation of dust
and debris is visible. To access, remove the 10 screws as shown in Fig. C.
Take care not to damage any interior components. Use a vacuum cleaner with a
brush tool or a cloth to
remove any debris from the coil. Pull tray out no more than 5 cm and wipe out
drip tray with a damp cloth. Do not tilt or remove tray, as damage may result.
Use a cotton swab to remove and debris that might prevent the white plastic
float ring from moving freely on the shaft. When finished, reassemble the
unit. Do not overtighten the screws. NOTICE: If the unit displays the
message “ER9 PUMP BLOCKED PUMP & HOSE”, inspect the pump filter (Fig. B),
and/or the float switch valve and pump tray (Fig. C) and clean as necessary.
Disassembly for Cleaning
Remove the 10 screws shown to access the drip tray, coils, and float switch for cleaning. Arrow shows location of float switch (see instructions).
SYSTEM MESSAGES
The Control Panel will display the following messages based on system performance and environmental conditions. User action, if any is required, is indicated in the third column.
C O N T R O L P A N E L M E S S A G E
|
E X P L A N A T I O N
|
U S E R A C T I O N
---|---|---
INITIALIZING| Unit is powering up.| None
FIRMWARE VERSION XXX| Indicates control board firmware version number.| None
FXXX-XXX| Model number.| None
OFF| Unit has finished powering up and is operating.| None
PLEASE WAIT COMP. DELAY XX| 60s delay before compressor turns on. Allows
system pressure to equalize.| None
UNIT ON XXXX HRS INLET XXX°F / XX%| First line: indicates total operating
hours.
Second line: Toggles between inlet temperature and inlet RH every 2 seconds.
| None
HUMIDISTAT INLET XXX°F / XX%| First line: indicates unit is in humidistat mode
Second line: Toggles between inlet temperature and inlet RH every 2 seconds.
| None
HI TEMP CYCLE REMAINING XX MIN| Unit overload limit reached. Cool-down
initiated.| None
—
PUMP PURGING XX
| Pump is purging with countdown in seconds. Press key again to
stop if needed.
| None
— DEFROST XX| Unit is defrosting, with countdown in seconds.| None
WAIT FOR DEFROST XXX| Unit turned off when coil is cold or already in a
defrost cycle. Proceeds to finish cycle or initiate one to clear the coils of
ice
before storage.
| None
WAIT FOR UNIT DRYING XXX| Occurs when unit is turned off and coil is not
frozen. Clears the coils of water before storage.| None
ERROR MESSAGES
If the control system detects an error, it will produce an error (“ER”) message. If this occurs, first unplug the unit and then plug it back in. This will usually reset the electronics, and the unit will begin operating normally. If the error message reappears, refer to the explanations and solutions shown below. If these solutions do not fix the problem, contact your local authorized service center.
C O N T R O L P A N E L M E S S A G E|
E X P L A N A T I O N A N D S O L U T I O N
---|---
ER4 DEFROST SENSOR CONNECT
or
ER4 OUTLET SENSOR CONNECT
|
Temp sensor is open, missing, or shorted. Check that temp sensors are installed correctly on control panel. If error persists, contact service.
ER5 SENSOR CONNECTION ON BD
|
Inlet Temp/RH sensor is open, missing, or shorted. Check that inlet temp/RH sensor is installed correctly on control panel and inlet shroud. If error persists, contact service.
ER6 CONTACT SERVICE CENTER
|
Current sensor failure. If error persists, contact service.
ER7 INVALID MODEL SETTING
|
Incorrect or unsupported DIP switch settings. Contact Dri-Eaz service department for correct DIP switch settings.
ER8 BUTTON STUCK ALL BUTTONS
|
Key is stuck or has been held down too long. Contact service.
ER9 PUMP BLOCKED PUMP & HOSE
|
Check for obstructions in drain hose. Check the pump.
TROUBLESHOOTING
F A U L T | C A U S E | S O L U T I O N |
---|---|---|
Water drips out when moving unit | Unit was unplugged before purging was | |
complete. | **** |
Purge unit before moving. See “At the End of the Job,” p. 5.
Unit does not operate| Unit not switched on. No power to machine.| Switch unit on.
Plug in unit; check power cord connection at wall outlet.
Unit operating, but room not dry
| Not enough time to dry. Poor air movement in room.
Excessive moist air infiltration.
| Allow more time for drying.
Increase air movement with air movers. Seal off area to reduce infiltration.
Unit collects too little water
| Room air is dry.
Room temperature is too low. Filter is clogged.
Coils are clogged.
| Confirm humidity level with hygrometer. Increase room temperature.
Check filter. Replace as necessary. Check coils. Clean as necessary.
If the problem you are experiencing is not listed here, contact your local distributor for further assistance.
SPECIFICATIONS
Name | Cube Dehumidifier #104411 | Cube Dehumidifier #104410 |
---|---|---|
Water removal 27°C/60% RH |
28 L/day
|
25 L/day
Water removal 30°C/80% RH|
43 L/day
|
42 L/day
Water removal 20°C/60% RH|
22 L/day
|
18 L/day
Process air movement| 220 m3/h| 220 m3/h
Dimensions (W × H × D)|
28.7 × 38.9 × 40.1 cm
|
28.7 × 38.9 × 40.1 cm
Weight (w/ cord and hose)|
22.7 kg
|
22.7 kg
Amps| 2.4A| 4.1A
Volts| 230V| 110V
Frequency| 50Hz| 50Hz
Power (compressor rating)|
1544 W
|
1377 W
Operating temperature range|
1°C–38°C
|
1°C–38°C
Sound level| Does not exceed 70 dB| Does not exceed 70 dB
Safety| CE| CE
Specifications are subject to change without notice. Some values may be
approximate.
- PARTS INCLUDED
- 6 m drain hose with quick-connect fitting.
- 7.6 m power cord.
- Mesh air filter
- FILTER REORDERS
- 4-PRO air filter #100424 (F587), 24 pk
- ADDITIONAL PRODUCT INFORMATION and current documentation is available at www.legendbrandseurope.com
- FOR PARTS AND SERVICE contact your local distributor.
References
- Legend Brands Patents - Legend Brands Patents
- Legend Brands Europe | Superior cleaning and environmental control solutions
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>