SonicWall® NSa 2700 Power Supply Installation and Replacement
This document provides instructions for installing or removing a power supply in your NSa 2700 network security appliance.
Review the Safety, Regulatory and Legal Information document provided with the NSa 2700 appliance.
Rear view of NSa 2700 appliance showing power supply locations:

SONICWALL NSA 2700 Power Supply - Replacement

Installing the Power Supply into the Appliance

WARNING: Do not install anything except the NSa 2700 Power Supply into the NSa 2700 appliance.

To install a new NSa 2700 Power Supply:

  1. Using a Phillips screwdriver, remove the screw securing the top to the power supply compartment.

  2. Slide the top toward the back of the appliance and then lift to remove, exposing the power supply compartment.

  3. Remove the thumbscrew holding the bracket and remove the bracket from the compartment.

  4. Plug the cord from the power supply into the matching interface in the back corner.

  5. Place the power supply in the compartment.
    SONICWALL NSA 2700 Power Supply - Place

  6. Secure the bracket with the thumbscrew.

  7.  Wrap the cord so it lies in the space beside the power supply.

  8. Place the top over the compartment, ensuring that the hook on the side goes into the matching slot, and slide into place. Secure the cover with the screw.

  9. Connect the external power cord to the power supply.

  10. Connect the other end of the cord to a power source.

Removing the Power Supply from the Appliance

WARNING: Power supply surfaces can be hot. Handle and store with care until the surfaces are cool.

  1. Remove the screw from the power supply compartment cover and slide the cover off.
  2. Remove the thumbscrew holding the bracket against the power supply.
  3. Remove the bracket.
  4. Unwrap the cable ties, if present.
  5. Unplug the internal power connector.
  6. Remove the power supply.

This power supply module is for use with SonicWall appliances indicated below. Use of this module with a SonicWall appliance that is not approved will void the warranty for that appliance. This module is provided as a replacement power supply, and is provided on an “as is” basis without warranty of any kind.
This power supply, 02-SSC-3078 SONICWALL NSA2700 / TZ670 / TZ570 SERIES FRU POWER SUPPLY, is approved for use with: 02-SSC-4324 SONICWALL NSA 2700
For information and related documents, see the following web site: https://www.sonicwall.com/support

Copyright © 2021 SonicWall Inc. All rights reserved.
SonicWall is a trademark or registered trademark of SonicWall Inc. and/or its affiliates in the U.S.A. and/or other countries. All other trademarks are property of their respective owners.
The information in this document is provided in connection with SonicWall Inc. and/or its affiliates’ products. No license, express or implied, by estoppel or otherwise, to any intellectual property right is granted by this document. SonicWall Inc. and/or its affiliates do not make any commitment to update the information contained in this document. For more information, visit http://www.sonicwall.com/legal.
Legend

WARNING: A WARNING icon indicates a potential for property damage, personal injury, or death.
IMPORTANT, NOTE, TIP, MOBILE, or VIDEO: An information icon indicates supporting information.

NSa 2700 Power Supply Installation Guide
Updated – January 2021
232-005575-50 Rev A

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals